DOPPLER ULTRASONIC SYSTEM FOR FLOW MEASUREMENT IN PATIENTS WITH DIABETIC FOOT USING RECONFIGURABLE LOGIC AND WISHBONE ARCHITECTURE

被引:0
|
作者
Carrillo, E. [1 ]
Jimenez, A. [1 ]
Moreno, E. [1 ]
Leija, L. [2 ]
Vera, A. [2 ]
Ramos, A. [3 ]
机构
[1] Inst Cibernet Matemat & Fis, Dept Fis Aplicada, Havana, Cuba
[2] CINVESTAV, Dept Ingn Elect, Secc Bioelect, Mexico City, DF, Mexico
[3] CSIC, Lab Sistemas Ultrason, Serrano 144, Madrid 28006, Spain
来源
REVISTA CUBANA DE FISICA | 2016年 / 33卷 / 02期
关键词
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The first results in the design of a pulsed Doppler ultrasound system are presented, which aims to detect alterations of diabetic foot cataloged as "high risk", associated with the processes that lead to occlusion of blood vessels. Therefore, measurement of blood flow gives the level of damage in the affected area and the state of the blood vessels, constituting a noninvasive diagnostic test. The system was designed from the classical conceptions of Pulsed Doppler systems and also, incorporates advanced digital design techniques based on hybrid hardware-software implementations (FPGA) on reconfigurable platforms. The analog system architecture is shown and finally, its most outstanding features and the expected results of the design are exposed.
引用
收藏
页码:83 / 88
页数:6
相关论文
共 50 条
  • [31] PULSED ULTRASONIC DOPPLER SYSTEM NON-INVASIVE METHOD FOR QUANTITATIVE BLOOD-FLOW MEASUREMENT
    GAMS, E
    ENGISCH, G
    GEBHARDT, K
    HAGL, S
    HEIMISCH, W
    MEISNER, H
    SEBENING, F
    THORAXCHIRURGIE VASKULARE CHIRURGIE, 1978, 26 : 36 - 36
  • [32] MEASUREMENT OF BLOOD-FLOW IN PORTAL-VEIN OF CONSCIOUS DOGS USING A PULSED DOPPLER ULTRASONIC FLOW METER
    ANDERSON, MF
    ALLEN, HV
    HARELL, GS
    CLINICAL RESEARCH, 1976, 24 (02): : A145 - A145
  • [33] NEONATAL CEREBRAL VENOUS FLOW VELOCITY-MEASUREMENT USING A COLOR FLOW DOPPLER SYSTEM
    FENTON, AC
    PAPATHOMA, E
    EVANS, DH
    LEVENE, MI
    JOURNAL OF CLINICAL ULTRASOUND, 1991, 19 (02) : 69 - 72
  • [34] Viscoelastic measurement of tissue-like phantom using a pulsed wave Doppler ultrasonic system
    Hou, CJ
    Chung, KC
    IEEE EMBS APBME 2003, 2003, : 270 - 271
  • [35] Measurement of liquid turbulent structure in bubbly flow at low void fraction using ultrasonic Doppler method
    Murakawa, H
    Kikura, H
    Aritomi, M
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2003, 40 (09) : 644 - 654
  • [36] PORTAL BLOOD-FLOW IN ACUTE HEPATITIS WITH AND WITHOUT ASCITES - A NONINVASIVE MEASUREMENT USING AN ULTRASONIC DOPPLER
    YANG, SS
    WU, CH
    CHEN, TK
    LEE, CL
    LAI, YC
    CHEN, DS
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 1995, 10 (01) : 36 - 41
  • [37] FLOW SPEED MEASUREMENT WITH DOPPLER EFFECT USING ULTRASONIC RECEIVER FOR SMALL-SIZED SMART CATHETER
    Matsui, Ryo
    Takei, Yusuke
    Nguyen Minh-Dung
    Takahata, Tomoyuki
    Matsumoto, Kiyoshi
    Shimoyama, Isao
    2015 28TH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS 2015), 2015, : 640 - 642
  • [38] EFFECT OF DISTURBED FLOW CONDITION ON UNCERTAINTY OF FLOWRATE MEASUREMENT USING ULTRASONIC DOPPLER VELOCITY PROFILE METHOD
    Wada, Sanehiro
    Furuichi, Noriyuki
    PROCEEDINGS OF THE ASME/JSME/KSME JOINT FLUIDS ENGINEERING CONFERENCE, 2015, VOL 2A: FORA, PT 2, 2016,
  • [39] Development of a novel flow metering system using ultrasonic velocity profile measurement
    Mori, M
    Takeda, Y
    Taishi, T
    Furuichi, N
    Aritomi, M
    Kikura, H
    EXPERIMENTS IN FLUIDS, 2002, 32 (02) : 153 - 160
  • [40] Development of a novel flow metering system using ultrasonic velocity profile measurement
    M. Mori
    Y. Takeda
    T. Taishi
    N. Furuichi
    M. Aritomi
    H. Kikura
    Experiments in Fluids, 2002, 32 : 153 - 160