Retrofitting Traditional Western Hunan Dwellings with Passive Strategies Based on Indoor Thermal Environment

被引:12
|
作者
Liu, Sheng [1 ]
Huang, Chunhua [2 ]
Liu, Yiming [3 ]
Shen, Jize [4 ]
Li, Zeng [5 ]
机构
[1] Chinese Univ Hong Kong, Sch Architecture, Hong Kong 999077, Hong Kong, Peoples R China
[2] Cent S Univ, Sch Architecture & Art, Changsha 410083, Hunan, Peoples R China
[3] Hunan Univ Technol, Sch Packing Design & Art, Zhuzhou 412007, Peoples R China
[4] Chongqing Univ, Fac Architecture & Urban Planning, Chongqing 400045, Peoples R China
[5] Yanhua Energy Conservat, Shanghai 200333, Peoples R China
关键词
Traditional dwelling; Thermal environment; Passive strategies; Thermal simulation; Predicted mean vote (PMV);
D O I
10.1061/(ASCE)AE.1943-5568.0000316
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The unique architectural style of Western Hunan traditional dwellings must be protected, and their poor indoor thermal environment should also be improved. This investigation sought to determine the optimal passive retrofitting methods for such timber-structure dwellings. An analysis of the thermal environment of a typical traditional dwelling in Western Hunan was carried out by field study and indoor thermal evaluation on the typically coldest and hottest days. Based on the test results, this study calculated the predicted mean vote (PMV) linear fit and the acceptable temperature ranges. Then, the optimum thicknesses of the envelope insulation layer and window-to-wall ratio were evaluated by numerical simulation software based on the thermal performance of different strategies. Finally, according to the thermal performance results of the orthogonal experiments and the calculated acceptable temperature, a final comprehensive retrofitting strategy, using ordinary insulating glass units (12-mm hollow layer), a 0.2 window-to-wall ratio improvement, a polyurethane foam insulation layer (10mm) for the double-fir external wall envelope, and reed foil (80mm) for the clay insulation layer roof, was optimized for the existing vernacular dwellings in rural areas of Western Hunan, which can decrease the annual load from 188.38 to 65.99 kW.h/m(2) and increase the acceptable temperature by 1,159h over the whole year. (C) 2018 American Society of Civil Engineers.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Optimization of Plane and Space of New Dwellings in Southern Anhui Province Based on Indoor Thermal Environment
    Bian, Mengyuan
    Huang, Zhijia
    Chen, Qing
    Liu, Guo
    Zhang, Yang
    Ding, Shanshan
    SUSTAINABILITY, 2022, 14 (09)
  • [22] The Impact of Traditional Raw Earth Dwellings' Envelope Retrofitting on Energy Saving: A Case Study from Zhushan Village, in West of Hunan, China
    Xie, Liang
    Li, Zhe
    Li, Jiayu
    Yang, Guanglei
    Jiang, Jishui
    Liu, Zhezheng
    Tong, Shuyuan
    ATMOSPHERE, 2022, 13 (10)
  • [23] Evaluation and Optimization of Interior Circadian Daylighting Performance for the Elderly in Traditional Dwellings: A Case Study in Western Hunan, China
    Liu, Jixin
    Li, Zhe
    Zhang, Zuopeng
    Xie, Liang
    Wu, Jiade
    SUSTAINABILITY, 2024, 16 (09)
  • [24] Passive retrofitting of office buildings to improve their energy performance and indoor environment: the OFFICE project
    Santamouris, M
    Dascalaki, E
    BUILDING AND ENVIRONMENT, 2002, 37 (06) : 575 - 578
  • [25] Retrofitting strategies for thermal comfort and sustainability in Ulaanbaatar's traditional housing
    Du, Pengcheng
    Hagishima, Aya
    JOURNAL OF BUILDING ENGINEERING, 2025, 101
  • [26] Optimization of Natural Ventilation of "Yinzi" Dwellings in Western Hunan Based on Orthogonal Experiment and CFD
    Liu, Sheng
    Huang, Chunhua
    BUILDINGS, 2016, 6 (03)
  • [27] Use of traditional passive strategies to reduce the energy use and carbon emissions in modern dwellings
    Srivastav, S.
    Jones, P. J.
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2009, 4 (03) : 141 - 149
  • [28] Analysis of the Indoor Thermal Environment and Passive Energy-Saving Optimization Design of Rural Dwellings in Zhalantun, Inner Mongolia, China
    Shao, Teng
    Zheng, Wuxing
    Jin, Hong
    SUSTAINABILITY, 2020, 12 (03)
  • [29] Indoor thermal environment of wooden-plank wall dwellings in summer in Chongqing
    徐亚男
    杨真静
    PENG Ming-xi
    Journal of Chongqing University(English Edition), 2016, 15 (03) : 119 - 126
  • [30] One-year Field Study on Indoor Environment of Huizhou Traditional Vernacular Dwellings in China
    Huang, Zhijia
    Yu, Mengqi
    Zheng, Liangji
    Gong, Cheng
    Wu, Zhouqin
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 1316 - 1322