Field Absolute Ballistic Laser Gravimeter

被引:0
|
作者
Bunin, I. A. [1 ]
Kalish, E. N. [1 ]
Nosov, D. A. [1 ]
Smirnov, M. G. [1 ]
Stus', Yu. F. [1 ]
机构
[1] Russian Acad Sci, Inst Automat & Electrometry, Pr Akademika Koptyuga 1, Novosibirsk 630090, Russia
关键词
ballistic laser gravimeter; optical length standard; multiple readings; field conditions;
D O I
10.3103/S8756699011050104
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
This paper describes an absolute ballistic laser gravimeter of a new generation developed at the Institute of Automation and Electrometry, Siberian Branch of the Russian Academy of Sciences. The device is intended for use under field conditions and has small dimensions and weight. The light source in the gravimeter interferometer is an optical standard with a wavelength lambda = 532 nm consisting of a traveling- wave Nd : YAG laser with intracavity frequency doubling and with a stabilization system for the saturated absorption resonances in molecular iodine. The instrumental standard error in measuring the absolute gravity by the gravimeter does not exceed +/- 5 center dot 10(-8) m/s2 (or 5 mu Gal).
引用
收藏
页码:476 / 482
页数:7
相关论文
共 50 条
  • [31] Measurements with the new GABL-M field ballistic gravimeter under tundra conditions
    V. D. Yushkin
    A. N. Sapunov
    Yu. F. Stus
    E. N. Kalish
    I. A. Bunin
    D. A. Nosov
    Measurement Techniques, 2012, 54 : 1111 - 1116
  • [32] Comment on 'Comparison of three digital fringe signal processing methods in a ballistic free-fall absolute gravimeter'
    Niebauer, T. M.
    METROLOGIA, 2011, 48 (03) : 227 - 228
  • [33] Absolute ballistic gravimeter ABG-VNIIM-1 by D.I. Mendeleyev Research Institute for Metrology
    Vitushkin L.F.
    Orlov O.A.
    Vitushkin, L.F. (L.F.Vitushkin@vniim.ru), 1600, Maik Nauka Publishing / Springer SBM (05): : 283 - 287
  • [34] Uncertainty propagation in a non-linear regression analysis: Application to a ballistic absolute gravimeter (IMGC-02)
    Bich, Walter
    D'Agostino, Giancarlo
    Germak, Alessandro
    Pennecchi, Francesca
    2007 IEEE INTERNATIONAL WORKSHOP ON ADVANCED METHODS FOR UNCERTAINTY ESTIMATION IN MEASUREMENT, 2007, : 30 - +
  • [35] Calibration of the superconducting gravimeter based on a cold atom absolute gravimeter at NIM
    王启宇
    冯金扬
    王少凯
    庄伟
    赵阳
    牟丽爽
    吴书清
    Chinese Physics B, 2018, 27 (12) : 254 - 259
  • [36] Vertical Adjustment of Interferometer Beam in a Ballistic Gravimeter
    Kalish, E. N.
    Stus', Yu F.
    Nosov, D. A.
    Sizikov, I. S.
    OPTOELECTRONICS INSTRUMENTATION AND DATA PROCESSING, 2020, 56 (03) : 236 - 241
  • [37] Vertical Adjustment of Interferometer Beam in a Ballistic Gravimeter
    E. N. Kalish
    Yu. F. Stus’
    D. A. Nosov
    I. S. Sizikov
    Optoelectronics, Instrumentation and Data Processing, 2020, 56 : 236 - 241
  • [38] A laser ballistic gravimeter GABL-M and observation results concerning variations of gravitational force
    Arnautov, G.P.
    Kalish, E.N.
    Smirnov, M.G.
    Stus', Yu.F.
    Tarasyuk, V.G.
    Avtomatika i Telemekhanika, 1994, (07): : 3 - 11
  • [39] Precision evaluation of calibration factor of a superconducting gravimeter using an absolute gravimeter
    Feng Jin-yang
    Wu Shu-qing
    Li Chun-jian
    Su Duo-wu
    Xu Jin-yi
    Yu Mei
    SEVENTH INTERNATIONAL SYMPOSIUM ON PRECISION MECHANICAL MEASUREMENTS, 2016, 9903
  • [40] Calibration of the superconducting gravimeter based on a cold atom absolute gravimeter at NIM
    Wang, Qiyu
    Feng, Jinyang
    Wang, Shaokai
    Zhuang, Wei
    Zhao, Yang
    Mou, Lishuang
    Wu, Shuqing
    CHINESE PHYSICS B, 2018, 27 (12)