SONOGRAPHICALLY HOMOGENEOUS ECHOGENIC AMNIOTIC-FLUID IN DETECTING MECONIUM-STAINED AMNIOTIC-FLUID

被引:0
|
作者
SHERER, DM [1 ]
ABRAMOWICZ, JS [1 ]
SMITH, SA [1 ]
WOODS, JR [1 ]
机构
[1] UNIV ROCHESTER,STRONG MEM HOSP,SCH MED & DENT,PERINATAL ULTRASOUND LAB,ROCHESTER,NY 14642
来源
OBSTETRICS AND GYNECOLOGY | 1991年 / 78卷 / 05期
关键词
D O I
暂无
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
A prospective study was performed to examine the hypothesis that sonographically homogeneous echogenic amniotic fluid (AF) may provide a marker for the presence of meconium-stained AF. Twenty term gestations in which homogeneous echogenic AF was demonstrated sonographically were compared with 40 cases with sonographically clear AF. Two cases in the study group had meconium-stained AF at delivery. All of the controls had clear fluid by amniocentesis (performed for lung maturation studies) immediately after the sonographic examination. Thus, homogeneous echogenic AF had a sensitivity of 100%, a specificity of 69%, a positive predictive value of 10%, and a negative predictive value of 100% in detecting meconium. We conclude that homogeneous echogenic AF does not necessarily detect meconium-stained AF.
引用
收藏
页码:819 / 822
页数:4
相关论文
共 50 条