NAFION-COATED CARBON-FIBER ELECTRODES FOR NEUROCHEMICAL STUDIES IN BRAIN-TISSUE

被引:174
|
作者
CAPELLA, P [1 ]
GHASEMZADEH, B [1 ]
MITCHELL, K [1 ]
ADAMS, RN [1 ]
机构
[1] UNIV KANSAS,DEPT CHEM,LAWRENCE,KS 66045
关键词
D O I
10.1002/elan.1140020303
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Extensive studies of the characteristics of electrochemically pretreated, Nafion‐coated carbon fibers used for in vivo electrochemistry are summarized. While electrochemical pretreatment provides high sensitivity for the monitoring of catecholamine neurotransmitters, it causes fibers to respond slowly. The ionomer film, which confers selectivity, adds relatively little to the electrode time constant. In terms of sensitivity and time constant changes, serious interactions occur during the course of the in vivo experiments while the electrodes are exposed to brain tissue. Fortunately, selectivity characteristics do not change during in vivo experiments. Postcalibration procedures and other measurement techniques that provide reliable experimental measurements are discussed. Copyright © 1990 VCH Publishers, Inc.
引用
收藏
页码:175 / 182
页数:8
相关论文
共 50 条
  • [21] AN AC-IMPEDANCE STUDY OF ELECTROCHEMICAL PROCESSES AT NAFION-COATED ELECTRODES
    RUBINSTEIN, I
    RISHPON, J
    GOTTESFELD, S
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1986, 133 (04) : 729 - 734
  • [22] CARBON ELECTRODES FOR STIMULATION OF BRAIN-TISSUE IN-VITRO
    NIKANDER, P
    JOURNAL OF NEUROCHEMISTRY, 1972, 19 (02) : 535 - &
  • [23] IN-VIVO ELECTROCHEMICAL MONITORING OF SEROTONIN IN SPINAL DORSAL HORN WITH NAFION-COATED MULTICARBON FIBER ELECTRODES
    RIVOT, JP
    CESPUGLIO, R
    PUIG, S
    JOUVET, M
    BESSON, JM
    JOURNAL OF NEUROCHEMISTRY, 1995, 65 (03) : 1257 - 1263
  • [24] CARBON-FIBER MICROELECTRODES MODIFIED WITH NAFION
    WEBER, J
    DUNSCH, L
    NEUDECK, A
    ELECTROANALYSIS, 1995, 7 (03) : 255 - 259
  • [25] Oxygen reduction on Nafion-coated thin-film palladium electrodes
    Erikson, Heiki
    Kasikov, Aarne
    Johans, Christoffer
    Kontturi, Kyosti
    Tammeveski, Kaido
    Sarapuu, Ave
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 652 (1-2) : 1 - 7
  • [26] PH-DEPENDENT PROCESSES AT NAFION(R)-COATED CARBON-FIBER MICROELECTRODES
    KAWAGOE, KT
    GARRIS, PA
    WIGHTMAN, RM
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1993, 359 (1-2): : 193 - 207
  • [27] Nafion-CNT coated carbon-fiber microelectrodes for enhanced detection of adenosine
    Ross, Ashley E.
    Venton, B. Jill
    ANALYST, 2012, 137 (13) : 3045 - 3051
  • [28] Nafion-coated bismuth film and Nafion-coated mercury film electrodes for anodic stripping voltammetry combined on-line with ICP-mass spectrometry
    Cao, Grace X.
    Jimenez, Omar
    Zhou, Feimeng
    Xu, Maotian
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2006, 17 (07) : 945 - 952
  • [29] SIGNAL STABILITY OF NAFION-COATED THIN MERCURY FILM ELECTRODES FOR STRIPPING VOLTAMMETRY
    HOYER, B
    JENSEN, N
    TALANTA, 1994, 41 (03) : 449 - 453
  • [30] CHEMICAL INVESTIGATIONS OF NAFION-COATED ELECTRODES USING TRANSITION-METAL COMPLEXES
    SCHMIDT, MH
    LEWIS, NS
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1987, 193 : 56 - ANYL