摘要
Extensive studies of the characteristics of electrochemically pretreated, Nafion‐coated carbon fibers used for in vivo electrochemistry are summarized. While electrochemical pretreatment provides high sensitivity for the monitoring of catecholamine neurotransmitters, it causes fibers to respond slowly. The ionomer film, which confers selectivity, adds relatively little to the electrode time constant. In terms of sensitivity and time constant changes, serious interactions occur during the course of the in vivo experiments while the electrodes are exposed to brain tissue. Fortunately, selectivity characteristics do not change during in vivo experiments. Postcalibration procedures and other measurement techniques that provide reliable experimental measurements are discussed. Copyright © 1990 VCH Publishers, Inc.
引用
收藏
页码:175 / 182
页数:8
相关论文
共 50 条
  • [1] NAFION-COATED CARBON-FIBER FOR ACETYLCHOLINE AND CHOLINE SENSORS
    NAVERA, EN
    SUZUKI, M
    TAMIYA, E
    TAKEUCHI, T
    KARUBE, I
    ELECTROANALYSIS, 1993, 5 (01) : 17 - 22
  • [2] Chronically Implanted, Nafion-Coated Ag/AgCl Reference Electrodes for Neurochemical Applications
    Hashemi, Parastoo
    Walsh, Paul L.
    Guillot, Thomas S.
    Gras-Najjar, Julie
    Takmakov, Pavel
    Crews, Fulton T.
    Wightman, R. Mark
    ACS CHEMICAL NEUROSCIENCE, 2011, 2 (11): : 658 - 666
  • [3] MEASUREMENT OF EXTRACELLULAR BASAL LEVELS OF SEROTONIN INVIVO USING NAFION-COATED CARBON-FIBER ELECTRODES COMBINED WITH DIFFERENTIAL PULSE VOLTAMMETRY
    CRESPI, F
    MARTIN, KF
    MARSDEN, CA
    NEUROSCIENCE, 1988, 27 (03) : 885 - 896
  • [4] VOLTAMMETRY OF DIHYDROXYPHENYLALANINE (L-DOPA) USING A NAFION-COATED CARBON-FIBER ULTRAMICROELECTRODE ARRAY
    ZHANG, XJ
    WANG, CF
    ZHOU, XY
    ANALYTICA CHIMICA ACTA, 1992, 265 (01) : 27 - 34
  • [5] DECREASED ASCORBATE SENSITIVITY WITH NAFION-COATED CARBON-FIBER ELECTRODES IN COMBINATION WITH COPPER(II) IONS FOR THE ELECTROCHEMICAL DETERMINATION OF ELECTROACTIVE SUBSTANCES INVIVO
    HULTHE, P
    HULTHE, B
    JOHANNESSEN, K
    ENGEL, J
    ANALYTICA CHIMICA ACTA, 1987, 198 : 197 - 206
  • [6] INTERFERENCE BY DOPAC AND ASCORBATE DURING ATTEMPTS TO MEASURE DRUG-INDUCED CHANGES IN NEOSTRIATAL DOPAMINE WITH NAFION-COATED, CARBON-FIBER ELECTRODES
    WIEDEMANN, DJ
    BASSETOMUSK, A
    WILSON, RL
    REBEC, GV
    WIGHTMAN, RM
    JOURNAL OF NEUROSCIENCE METHODS, 1990, 35 (01) : 9 - 18
  • [7] ELECTROCHEMICAL DETERMINATION OF ELECTROINACTIVE MEDICINES WITH NAFION-COATED ELECTRODES
    MATSUE, T
    AOKI, A
    UCHIDA, I
    OSA, T
    CHEMISTRY LETTERS, 1987, (05) : 957 - 958
  • [8] Electrochemical impedance characterization of Nafion-coated carbon film resistor electrodes for electroanalysis
    Gouveia-Caridade, C
    Brett, CMA
    ELECTROANALYSIS, 2005, 17 (07) : 549 - 555
  • [9] NAFION-COATED MERCURY-COATED GLASSY-CARBON ELECTRODES FOR METALS ANALYSIS AND SPECIATION
    GUY, RD
    NAMARATNE, S
    CANADIAN JOURNAL OF CHEMISTRY-REVUE CANADIENNE DE CHIMIE, 1987, 65 (05): : 1133 - 1138
  • [10] Hydrogen oxidation on partially immersed Nafion-coated electrodes
    Kyoto Univ, Kyoto, Japan
    J Electroanal Chem, 1-2 (105-111):