EVALUATION OF BLOOD-PRESSURE MEASURING DEVICES

被引:12
|
作者
OBRIEN, E
ATKINS, N
MEE, F
OMALLEY, K
机构
[1] Blood Pressure Unit, Beaumont Hospital
关键词
BLOOD PRESSURE MEASURING DEVICES; VALIDATION; AAMI PROTOCOL; BHS PROTOCOL;
D O I
10.3109/10641969309037096
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Validation of blood pressure measuring devices is a relatively new field of research. There are two national protocols for validating blood pressure measuring devices: the protocol of the American Association for the Advancement of Medical Instrumentation (AAMI) and the protocol of the British Hypertension Society (BHS), each of which has recently been revised. 19 blood pressure measuring devices have been validated according to one or both of these protocols. These protocols have been beneficial in drawing attention to the potential inaccuracy of blood pressure measuring systems, they permit comparison between devices and they have brought manufacturers of blood pressure measuring devices into closer contact with the profession. There are some inherent weaknesses in both protocols which include the fallibility of the 'gold standard', the lack of provision for validation in special circumstances and in special groups, such as the elderly and pregnant women, and failure to allow for deteriorating accuracy with higher pressure levels. The revised BHS protocol attempts to redress these deficiencies.
引用
收藏
页码:1087 / 1097
页数:11
相关论文
共 50 条
  • [41] COMPARISON OF METHODS OF MEASURING BLOOD-PRESSURE
    ALTMAN, DG
    BLAND, JM
    JOURNAL OF EPIDEMIOLOGY AND COMMUNITY HEALTH, 1986, 40 (03) : 274 - 275
  • [42] EVALUATION OF THE VITA-STAT AUTOMATIC BLOOD-PRESSURE MEASURING DEVICE
    POLK, BF
    ROSNER, B
    CIRCULATION, 1979, 60 (04) : 126 - 126
  • [43] THE ACCURACY OF ELECTRONIC BLOOD-PRESSURE DEVICES
    TERBLANCHE, J
    COMBRINK, LW
    JOURNAL OF DENTAL RESEARCH, 1988, 67 (04) : 781 - 781
  • [44] IDENTIFICATION AND EVALUATION OF NON-INVASIVE BLOOD-PRESSURE MEASURING TECHNIQUES
    HASSLER, CR
    LUTZ, GA
    LINEBAUGH, R
    CUMMINGS, KD
    TOXICOLOGY AND APPLIED PHARMACOLOGY, 1979, 47 (02) : 193 - 201
  • [45] EVALUATION OF THE VITA-STAT AUTOMATIC BLOOD-PRESSURE MEASURING DEVICE
    POLK, BF
    ROSNER, B
    FEUDO, R
    VANDENBURGH, M
    HYPERTENSION, 1980, 2 (02) : 221 - 227
  • [46] DEVICES FOR MONITORING BLOOD-PRESSURE AT HOME
    不详
    MEDICAL LETTER ON DRUGS AND THERAPEUTICS, 1977, 19 (13): : 55 - 56
  • [47] EVALUATING AUTOMATED BLOOD-PRESSURE DEVICES
    SMALL, CF
    MCEWEN, JA
    COX, NB
    JOHNSON, DL
    LANCET, 1981, 2 (8250): : 805 - 805
  • [48] ESTIMATES OF BLOOD-PRESSURE VARIABILITY IN ADOLESCENTS USING AN AUTOMATIC BLOOD-PRESSURE MEASURING DEVICE
    LOMBARDI, DA
    GILLMAN, MW
    ELLISON, RC
    HOSMER, DW
    PULEO, EM
    JOURNAL OF HUMAN HYPERTENSION, 1994, 8 (06) : 441 - 443
  • [49] AMBULATORY BLOOD-PRESSURE MEASUREMENT IN THE EVALUATION OF BLOOD-PRESSURE LOWERING DRUGS
    OBRIEN, E
    COX, JP
    OMALLEY, K
    JOURNAL OF HYPERTENSION, 1989, 7 (04) : 243 - 247
  • [50] NONINVASIVE CONTINUOUS BLOOD-PRESSURE MEASUREMENT DURING ANESTHESIA - A CLINICAL-EVALUATION OF A METHOD COMMONLY USED IN MEASURING DEVICES
    DEJONG, JR
    ROS, HH
    DELANGE, JJ
    INTERNATIONAL JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1995, 12 (01): : 1 - 10