Evaluation of FISH for Blood Cultures under Diagnostic Real-Life Conditions

被引:3
|
作者
Reitz, Annalena [1 ]
Poppert, Sven [2 ,3 ]
Rieker, Melanie [4 ]
Frickmann, Hagen [5 ,6 ]
机构
[1] Goethe Univ, Univ Hosp, Frankfurt, Germany
[2] Swiss Trop & Publ Hlth Inst, Basel, Switzerland
[3] Univ Basel, Fac Med, Basel, Switzerland
[4] MVZ Humangenet Ulm, Ulm, Germany
[5] Bundeswehr Hosp Hamburg, Dept Microbiol & Hosp Hyg, Bernhard Nocht Str 74, D-20359 Hamburg, Germany
[6] Univ Hosp Rostock, Inst Med Microbiol Virol & Hyg, Rostock, Germany
来源
EUROPEAN JOURNAL OF MICROBIOLOGY AND IMMUNOLOGY | 2018年 / 8卷 / 04期
关键词
fluorescence in-situ hybridization; blood culture; rapid diagnostics; molecular diagnostics; sepsis;
D O I
10.1556/1886.2018.00024
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Background: The study assessed a spectrum of previously published in-house fluorescence in-situ hybridization (FISH) probes in a combined approach regarding their diagnostic performance with incubated blood culture materials. Methods: Within a two-year interval, positive blood culture materials were assessed with Gram and FISH staining. Previously described and new FISH probes were combined to panels for Gram-positive cocci in grape-like clusters and in chains, as well as for Gram-negative rod-shaped bacteria. Covered pathogens comprised Staphylococcus spp., such as S. aureus, Micrococcus spp., Enterococcus spp., including E. faecium, E. faecalis, and E. gallinarum, Streptococcus spp., like S. pyogenes, S. agalactiae, and S. pneumoniae, Enterobacteriaceae, such as Escherichia coli, Klebsiella pneumoniae and Salmonella spp., Pseudomonas aeruginosa, Stenotrophomonas maltophilia, and Bacteroides spp. Results: A total of 955 blood culture materials were assessed with FISH. In 21 (2.2%) instances, FISH reaction led to non-interpretable results. With few exemptions, the tested FISH probes showed acceptable test characteristics even in the routine setting, with a sensitivity ranging from 28.6% (Bacteroides spp.) to 100% (6 probes) and a specificity of >95% in all instances. Conclusion: If sophisticated rapid diagnostic methods like mass spectrometry from blood culture materials are not available, FISH provides an option for rapid differentiation for laboratories in resource-limited settings.
引用
收藏
页码:135 / 141
页数:7
相关论文
共 50 条
  • [21] Austrian Experience with Lixisenatide Under Real-Life Conditions: A Prospective Observational Study
    Helmut Brath
    Heidemarie Abrahamian
    Tvrtko Karuza
    Roman Mihaljevic
    Martin Pfohl
    Diabetes Therapy, 2019, 10 : 451 - 462
  • [22] Myopic accommodation responses are more accurate under 'real-life' viewing conditions
    Hazel, CA
    Strang, NC
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U336 - U336
  • [23] Austrian Experience with Lixisenatide Under Real-Life Conditions: A Prospective Observational Study
    Brath, Helmut
    Abrahamian, Heidemarie
    Karuza, Tvrtko
    Mihaljevic, Roman
    Pfohl, Martin
    DIABETES THERAPY, 2019, 10 (02) : 451 - 462
  • [24] Neural mechanisms supporting evaluation of others’ errors in real-life like conditions
    Iiro P. Jääskeläinen
    Hanna-Leena Halme
    Yigal Agam
    Enrico Glerean
    Juha M Lahnakoski
    Mikko Sams
    Karoliina Tapani
    Jyrki Ahveninen
    Dara S. Manoach
    Scientific Reports, 6
  • [25] Neural mechanisms supporting evaluation of others' errors in real-life like conditions
    Jaaskelainen, Iiro P.
    Halme, Hanna-Leena
    Agam, Yigal
    Glerean, Enrico
    Lahnakoski, Juha M.
    Sams, Mikko
    Tapani, Karoliina
    Ahveninen, Jyrki
    Manoach, Dara S.
    SCIENTIFIC REPORTS, 2016, 6
  • [26] Evaluation under real-life conditions of a lifestyle intervention for diabetes prevention developed by the municipal health services of Madrid, Spain
    Martin-Ridaura, Carmen
    Ochoa-Esteban, Dario
    Berlinches-Zapero, Carmen
    Ruiz-Fernandez, Dolores
    Sanz-Martin, Vanessa
    Gavira-Izquierdo, Rosario
    March, Sebastia
    Lopez-Toribio, Maria
    Ceinos-Arcones, Mercedes
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [27] Efficacy and tolerability of quetiapine in hospitalized patients with schizophrenia assessed under "real-life" conditions:: A German in practice evaluation programme
    Riedel, M.
    Severus, E.
    Reimitz, R.
    Koehler, J.
    INTERNATIONAL JOURNAL OF NEUROPSYCHOPHARMACOLOGY, 2006, 9 : S149 - S150
  • [28] Evaluation under real-life conditions of a lifestyle intervention for diabetes prevention developed by the municipal health services of Madrid, Spain
    Carmen Martin-Ridaura
    Darío Ochoa-Esteban
    Carmen Berlinches-Zapero
    Dolores Ruiz-Fernández
    Vanessa Sanz-Martín
    Rosario Gavira-Izquierdo
    Sebastià March
    María López-Toribio
    Mercedes Ceinos-Arcones
    Scientific Reports, 12
  • [29] Particulate emissions from residential wood combustion. Evaluation under real-life operating conditions and toxicological relevance
    Wohter, Daniel
    Quicker, Peter Georg
    Brand, Peter
    Kraus, Thomas
    BUNDESGESUNDHEITSBLATT-GESUNDHEITSFORSCHUNG-GESUNDHEITSSCHUTZ, 2018, 61 (06) : 667 - 673
  • [30] Effectiveness of Quetiapine in Outpatients With Schizophrenia Assessed Under "Real-Life" Conditions A German Clinical-Practice Evaluation Programme
    Riedel, Michael
    Severus, Emanuel
    Schennach-Wolff, Rebecca
    Musil, Richard
    Spellmann, Ilja
    Oppolzer, Birgit
    Moeller, Hans-Juergen
    Koehler, Juergen
    Seemueller, Florian
    JOURNAL OF CLINICAL PSYCHOPHARMACOLOGY, 2011, 31 (01) : 120 - 122