Differential dose contributions on total dose distribution of I-125 brachytherapy source

被引:6
|
作者
Camgoz, B. [1 ]
Yegin, G. [2 ]
Kumru, M. N. [1 ]
机构
[1] Ege Univ, Inst Nucl Sci, Izmir, Turkey
[2] Celal Bayar Univ, Sci Fac, Phys Dept, Manisa, Turkey
关键词
Monte Carlo; Brachytherapy; Radiation dose;
D O I
10.1016/j.rpor.2010.04.003
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
This work provides an improvement of the approach using Monte Carlo simulation for the Amersham Model 6711 I-125 brachytherapy seed source, which is well known by many theoretical and experimental studies. The source which has simple geometry was researched with respect to criteria of AAPM Tg-43 Report. The approach offered by this study involves determination of differential dose contributions that come from virtual partitions of amassive radioactive element of the studied source to a total dose at analytical calculation point. Some brachytherapy seeds contain multi-radioactive elements so the dose at any point is a total of separate doses from each element. It is momentous to know well the angular and radial dose distributions around the source that is located in cancerous tissue for clinical treatments. Interior geometry of a source is effective on dose characteristics of a distribution. Dose information of inner geometrical structure of a brachytherapy source cannot be acquired by experimental methods because of limits of physical material and geometry in the healthy tissue, so Monte Carlo simulation is a required approach of the study. EGSnrc Monte Carlo simulation software was used. In the design of a simulation, the radioactive source was divided into 10 rings, partitioned but not separate from each other. All differential sources were simulated for dose calculation, and the shape of dose distribution was determined comparatively distribution of a single-complete source. In this work anisotropy function was examined also mathematically. (C) 2010 Greater Poland Cancer Centre, Poland. Published by Elsevier Urban & Partner Sp. z.o.o. All rights reserved.
引用
收藏
页码:69 / 74
页数:6
相关论文
共 50 条
  • [31] Dose-rate constant for Imagyn 125I brachytherapy source
    Ibbott, GS
    Nath, R
    MEDICAL PHYSICS, 2001, 28 (04) : 705 - 705
  • [32] QUANTIFYING THE EFFECT OF DOSE INHOMOGENEITY IN BRACHYTHERAPY - APPLICATION TO PERMANENT PROSTATIC IMPLANT WITH I-125 SEEDS
    LING, CC
    ROY, J
    SAHOO, N
    WALLNER, K
    ANDERSON, L
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (04): : 971 - 978
  • [33] The PTB primary standard for the absorbed-dose to water for I-125 interstitial brachytherapy sources
    Schneider, T.
    METROLOGIA, 2012, 49 (05) : S198 - S202
  • [34] DOSE DISTRIBUTION AND MAXIMUM PERMISSIBLE BURDEN OF I-125 IN THYROID-GLAND
    GAVRON, A
    FEIGE, Y
    HEALTH PHYSICS, 1972, 23 (04): : 491 - +
  • [35] MONTE-CARLO SIMULATION OF THE DOSE DISTRIBUTION AROUND I-125 SEEDS
    BURNS, GS
    RAESIDE, DE
    MEDICAL PHYSICS, 1987, 14 (03) : 420 - 424
  • [36] How well can we predict the dose distribution from TRUS images made at the OR after I-125 brachytherapy of the prostate?
    Steggerda, M.
    Van den Boom, F.
    Witteveen, T.
    Moonen, L.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S62 - S63
  • [37] DOSE-RATE DETERMINATION FOR I-125 SEEDS
    CHIUTSAO, ST
    ANDERSON, LL
    OBRIEN, K
    SANNA, R
    MEDICAL PHYSICS, 1990, 17 (05) : 815 - 825
  • [38] Preliminary research for mutual dose perturbation influence of 125I brachytherapy source
    Sun, Liang
    Li, Junli
    Cheng, Jianping
    Zhang, Hui
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2007, 44 (08) : 1095 - 1099
  • [39] Practical Nomograms Based on Dose-volume Histogram Parameters to Predict Total Seed Activity for I-125 Permanent Prostate Brachytherapy
    Arimura, T.
    Nakamura, F.
    Ito, S.
    Hiraki, Y.
    Ueyama, T.
    Enokida, H.
    Nakagawa, M.
    Nakajo, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S378 - S379
  • [40] The use of Monte Carlo simulations to study the radiation dose distributin in prostate implant brachytherapy with I-125
    Badragan, I
    MEDICAL PHYSICS, 2003, 30 (07) : 1950 - 1950