Differential dose contributions on total dose distribution of I-125 brachytherapy source

被引:6
|
作者
Camgoz, B. [1 ]
Yegin, G. [2 ]
Kumru, M. N. [1 ]
机构
[1] Ege Univ, Inst Nucl Sci, Izmir, Turkey
[2] Celal Bayar Univ, Sci Fac, Phys Dept, Manisa, Turkey
关键词
Monte Carlo; Brachytherapy; Radiation dose;
D O I
10.1016/j.rpor.2010.04.003
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
This work provides an improvement of the approach using Monte Carlo simulation for the Amersham Model 6711 I-125 brachytherapy seed source, which is well known by many theoretical and experimental studies. The source which has simple geometry was researched with respect to criteria of AAPM Tg-43 Report. The approach offered by this study involves determination of differential dose contributions that come from virtual partitions of amassive radioactive element of the studied source to a total dose at analytical calculation point. Some brachytherapy seeds contain multi-radioactive elements so the dose at any point is a total of separate doses from each element. It is momentous to know well the angular and radial dose distributions around the source that is located in cancerous tissue for clinical treatments. Interior geometry of a source is effective on dose characteristics of a distribution. Dose information of inner geometrical structure of a brachytherapy source cannot be acquired by experimental methods because of limits of physical material and geometry in the healthy tissue, so Monte Carlo simulation is a required approach of the study. EGSnrc Monte Carlo simulation software was used. In the design of a simulation, the radioactive source was divided into 10 rings, partitioned but not separate from each other. All differential sources were simulated for dose calculation, and the shape of dose distribution was determined comparatively distribution of a single-complete source. In this work anisotropy function was examined also mathematically. (C) 2010 Greater Poland Cancer Centre, Poland. Published by Elsevier Urban & Partner Sp. z.o.o. All rights reserved.
引用
收藏
页码:69 / 74
页数:6
相关论文
共 50 条
  • [1] Brachytherapy - High Dose Rate or I-125?
    Hoskin, P. J.
    EUROPEAN JOURNAL OF CANCER, 2011, 47 : S65 - S66
  • [2] Measurement of I-125 Brachytherapy Dose in Lung
    Gayou, O.
    Kim, Y.
    Johnson, M.
    Colonias, A.
    Werts, E. D.
    MEDICAL PHYSICS, 2012, 39 (06) : 3779 - 3779
  • [3] A Monte Carlo investigation of the dose distribution for new I-125 Low Dose Rate brachytherapy source in water and in different media
    Fardi, Zeinab
    Taherparvar, Payvand
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2019, 25 (01): : 15 - 22
  • [4] INTERSEED EFFECTS ON DOSE FOR I-125 BRACHYTHERAPY IMPLANTS
    MEIGOONI, AS
    MELI, JA
    NATH, R
    MEDICAL PHYSICS, 1992, 19 (02) : 385 - 390
  • [5] Plaque Size and Dose in I-125 Eye Plaque Brachytherapy
    Binder, C.
    Crilly, R. J.
    Brown, S.
    Skalet, A.
    Hung, A. Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E596 - E596
  • [6] DIFFERENTIAL LOADING IN TEMPORARY IMPLANT WITH I-125 - EVALUATION OF DOSE DISTRIBUTION ACHIEVED
    BARNETT, C
    HUANG, D
    ROBERTS, B
    PHILLIPS, T
    LING, C
    MEDICAL PHYSICS, 1987, 14 (03) : 476 - 476
  • [7] MICROSCOPIC DOSE DISTRIBUTION DUE TO I-125 IN THYROID
    GILLESPIE, FC
    ORR, JS
    GREIG, WR
    BRITISH JOURNAL OF RADIOLOGY, 1971, 44 (527): : 907 - +
  • [8] DOSE DISTRIBUTION OF I-125 SOURCES IN DIFFERENT TISSUES
    HUANG, DYC
    SCHELL, MC
    WEAVER, KA
    LING, CC
    MEDICAL PHYSICS, 1990, 17 (05) : 826 - 832
  • [9] REALIZATION OF THE ABSORBED DOSE TO WATER FOR I-125 INTERSTITIAL BRACHYTHERAPY SOURCES
    Schneider, T.
    Selbach, H. J.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S66 - S66
  • [10] Realisation of the absorbed dose to water for I-125 interstitial brachytherapy sources
    Schneider, Thorsten
    Selbach, Hans-Joachim
    RADIOTHERAPY AND ONCOLOGY, 2011, 100 (03) : 442 - 445