The authors measure the absolute spectral sensitivity of an x-ray image converter (XIC) with a beryllium window and a microchannel plate as a converting and amplifying element in the energy range of x-ray quanta of 7 to 20 keV. The measurements are performed in the synchrotron-radiation channel of the VEPP-3M accumulator of the Institute of Nuclear Physics of the Siberian Division of the Academy of Sciences of the USSR. It is shown that in the indicated energy range the ratio of the number of photons in the blue region of the spectrum at the exit from the XIC to the number of x-ray quanta at the entrance increases from 1200 to 2200 photons per quantum. The sensitivity variation over the working field of the XIC is studied.
引用
收藏
页码:950 / 952
页数:3
相关论文
共 50 条
  • [41] VERSATILE X-RAY SPECTROMETER IN RANGE 5-200 KEV
    STRACHAN, JD
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1976, 47 (12): : 1542 - 1546
  • [42] A Technique for Registration of Absolute Fluxes of X-Ray Laser Plasma Radiation in the 0.15–1.0 keV Spectral Range with the Spectral λ/Δλ ≈ 20 and 30 ps Time Resolutions
    A. N. Muntyan
    S. I. Petrov
    N. M. Romanova
    E. V. Sankin
    Instruments and Experimental Techniques, 2021, 64 : 230 - 233
  • [43] Spectral measurements of X-ray binary pulsars in hard X-ray region of 20-200 KeV
    Manchanda, RK
    ASTROPHYSICAL LETTERS & COMMUNICATIONS, 1999, 38 (1-6) : 101 - 104
  • [44] DIFFUSE COSMIC X-RAY BACKGROUND FROM 20 TO 220 KEV
    BLEEKER, JAM
    DEERENBERG, AJ
    ASTROPHYSICAL JOURNAL, 1970, 159 (1P1): : 215 - +
  • [45] Photoelectron recoil in CO in the x-ray region up to 7 keV
    Kukk, E.
    Thomas, T. D.
    Ueda, K.
    Ceolin, D.
    Granroth, S.
    Kooser, K.
    Travnikova, O.
    Iablonsky, D.
    Decleva, P.
    Ayuso, D.
    Puettner, R.
    Levola, H.
    Goldsztejn, G.
    Marchenko, T.
    Piancastelli, M. N.
    Simon, M.
    PHYSICAL REVIEW A, 2017, 95 (04)
  • [46] The dynamic range of X-ray imaging with image plates
    Thoms, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 389 (03): : 437 - 440
  • [47] The 7 keV axion dark matter and the X-ray line signal
    Higaki, Tetsutaro
    Jeong, Kwang Sik
    Takahashi, Fuminobu
    PHYSICS LETTERS B, 2014, 733 : 25 - 31
  • [48] A Technique for Registration of Absolute Fluxes of X-Ray Laser Plasma Radiation in the 0.15-1.0 keV Spectral Range with the Spectral λ/Δλ ≈ 20 and 30 ps Time Resolutions
    Muntyan, A. N.
    Petrov, S., I
    Romanova, N. M.
    Sankin, E., V
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2021, 64 (02) : 230 - 233
  • [49] A NEW SOLID-STATE X-RAY IMAGE CONVERTER
    KOHASHI, T
    PROCEEDINGS OF THE IEEE, 1963, 51 (12) : 1794 - &
  • [50] NANOSECOND FRAME X-RAY IMAGE CONVERTER WITH A MICROCHANNEL PLATE
    ARANCHUK, LE
    AIVAZOV, IK
    BOGOLYUBSKII, SL
    VOLKOV, GS
    ZAIDEL, IN
    PEREVODCHIKOVA, GI
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1983, 26 (01) : 190 - 193