COMPARISON OF DIGITAL ANGIOGRAMS WITH CONVENTIONAL CINEANGIOGRAMS FOR THE QUANTITATION OF CORONARY-ARTERY STENOSIS BEFORE AND AFTER ANGIOPLASTY

被引:0
|
作者
STEVENSON, RN [1 ]
ROBERTS, RH [1 ]
BRECKER, SJ [1 ]
TIMMINS, PJ [1 ]
WILKINSON, PD [1 ]
BALCON, R [1 ]
机构
[1] LONDON CHEST HOSP, DEPT CARDIOL, LONDON E2 9JX, ENGLAND
关键词
DIGITAL ANGIOGRAPHY; CINEANGIOGRAPHY; ANGIOPLASTY;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: It is currently unknown how digital images viewed during angioplasty compare with cineangiograms taken at the end of the procedure for estimating lesion severity, and detecting intimal dissection. The aim of this study, therefore, was to compare the two imaging techniques in assessing lesion severity and morphology before and after angioplasty. Methods: Digital angiograms and cineangiograms acquired before and after 50 consecutive angioplasties were analyzed blindly by two experienced observers. To assess inter-observer variability, angiograms were also analyzed independently by a second pair of observers. Results: There was no significant difference in the overall mean percent diameter stenosis measured by the two imaging techniques (preangioplasty: 77% cine, 80% digital, mean difference 2.6%, postangioplasty: 34% cine, 35% digital, mean difference 1.7%), suggesting that there is no appreciable systematic difference between modalities. However, wide limits of agreement between the techniques (preangioplasty: -24.6% to 29.7%, postangioplasty: -23.1% to 26.5%) indicate relatively large discrepancies in individual measurements. Interobserver variability was of a similar magnitude, and this may account for much of the apparent variability between techniques. Concordance between imaging modalities on the presence or absence of intimal dissection was similar to concordance between observers, suggesting that detection of intimal dissection depends more on observer judgment than image quality. Importantly, interobserver variability was similar for both imaging techniques, Conclusions: The results of this study indicate that digital imaging is comparable to cineangiography in assessing lesion severity and morphology before and after coronary angioplasty. There are clear limitations to the visual assessment of coronary stenoses.
引用
收藏
页码:1183 / 1188
页数:6
相关论文
共 50 条
  • [41] NONOPERATIVE DILATATION OF CORONARY-ARTERY STENOSIS - PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY
    GRUNTZIG, AR
    SENNING, A
    SIEGENTHALER, WE
    NEW ENGLAND JOURNAL OF MEDICINE, 1979, 301 (02): : 61 - 68
  • [42] PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY OF THE VERY PROXIMAL CORONARY-ARTERY STENOSIS
    NAKHJAVAN, FK
    GOLDMAN, AP
    HUTT, GH
    WERTHEIMER, JH
    YAZDANFAR, S
    MARANHAO, V
    WEINER, R
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1987, 13 (02): : 87 - 92
  • [43] EVALUATION OF TRANS-LUMINAL CORONARY ANGIOPLASTY IN LEFT MAIN CORONARY-ARTERY STENOSIS
    STERTZER, SH
    WALLSH, E
    BRUNO, MS
    AMERICAN JOURNAL OF CARDIOLOGY, 1981, 47 (02): : 396 - 396
  • [44] PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY FOR VERY PROXIMAL CORONARY-ARTERY STENOSIS
    NAKHJAVAN, FK
    GOLDMAN, AP
    HUTT, G
    MORANHAO, V
    WEINER, R
    WERTHEIMER, JH
    YAZDANFAR, S
    CHEST, 1986, 89 (06) : S474 - S474
  • [45] COMPARISON OF EXERCISE TEST RESPONSES BEFORE AND AFTER EITHER PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY OR CORONARY-ARTERY BYPASS-GRAFTING
    DUBACH, P
    LEHMANN, KG
    FROELICHER, VF
    AMERICAN JOURNAL OF CARDIOLOGY, 1989, 64 (16): : 1039 - 1041
  • [46] PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY AS ALTERNATIVE TREATMENT TO CORONARY-ARTERY BYPASS-SURGERY IN IATROGENIC STENOSIS OF THE LEFT MAIN CORONARY-ARTERY
    MARTI, V
    AUGE, JM
    PICART, JG
    GUITERAS, P
    BALLESTER, M
    OBRADOR, D
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 1995, 8 (03) : 229 - 231
  • [47] RECURRENT STENOSIS AND CORONARY-ARTERY SPASM AT THE SITE OF ANGIOPLASTY IN PATIENT WITH VARIANT ANGINA AFTER SUCCESSFUL PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY
    SATO, M
    NOSAKA, H
    HIBINO, H
    MIOKA, S
    KIMURA, T
    KUROSAWA, Y
    OTSUKA, S
    YOKOI, H
    HOSOKAWA, H
    ARAKAWA, M
    YASUMOTO, H
    KIDA, M
    SHIROTANI, M
    MORISHITA, H
    TACHIBANA, H
    NOBUYOSHI, M
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1986, 50 (06): : 548 - 548
  • [48] COMPARISON OF PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY VERSUS CORONARY-ARTERY BYPASS-GRAFTING FOR MULTIVESSEL CORONARY-ARTERY DISEASE
    VACEK, JL
    ROSAMOND, TL
    STITES, HW
    ROWE, SK
    ROBUCK, W
    DITTMEIER, G
    BEAUCHAMP, GD
    AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (06): : 592 - 597
  • [49] APPLICATION OF ADAPTIVE FTF/FAEST ZERO TRACKING FILTERS TO NONINVASIVE CHARACTERIZATION OF THE SOUND PATTERN CAUSED BY CORONARY-ARTERY STENOSIS BEFORE AND AFTER ANGIOPLASTY
    AKAY, M
    AKAY, YM
    WELKOWITZ, W
    SEMMLOW, JL
    KOSTIS, J
    ANNALS OF BIOMEDICAL ENGINEERING, 1993, 21 (01) : 9 - 17
  • [50] Effect of cilostazol on restenosis after coronary angioplasty and stenting in comparison to conventional coronary artery stenting with ticlopidine
    Tanabe, Y
    Ito, E
    Nakagawa, I
    Suzuki, K
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2001, 78 (03) : 285 - 291