The effect of pneumoperitoneum and Trendelenburg position on respiratory mechanics during pelviscopic surgery

被引:45
|
作者
Suh, Min Kyo [1 ]
Seong, Kyu Wan [1 ]
Jung, Sung Hwan [1 ]
Kim, Seong Su [1 ]
机构
[1] Univ Ulsan, Gangneung Asan Hosp, Coll Med, Dept Anesthesiol & Pain Med, 415 Bangdong Ri,Sacheon Myeon, Kangnung 210711, South Korea
关键词
Airway pressure; Head-down tilt; Lung compliance; Pelviscopy; Pneumoperitoneum;
D O I
10.4097/kjae.2010.59.5.329
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Conventional pelviscopic surgery requires pneumoperitoneum with CO2 gas insufflation and lithotomy-Trendelenburg position. Pneumoperitoneum and Trendelenburg position may influence intraoperative respiratory mechanics in anesthetic management. This study was conducted to investigate the influence of pneumoperitoneum and Trendelenburg position on respiratory compliance and ventilation pressure. Methods: Twenty-five patients scheduled for elective gynecologic laparoscopy were evaluated. The patients had no preexisting lung or heart disease or pathologic lung function. Conventional general anesthesia with thiopental sodium, lidocaine, rocuronium, and sevoflurane was administered. The peak inspiratory pressure, plateau pressure, and end-tidal CO2 were measured before and after creation of pneumoperitoneum with an intraabdominal pressure of 12 mmHg, then after 10 minutes and 30 minutes in the 20 degrees Trendelenburg position, and after deflation of pneumoperitoneum. The dynamic lung compliance was then calculated. Results: Following creation of pneumoperitoneum, there was a significant increase in peak inspiratory pressure (6 cmH(2)O), plateau pressure (7 cmH(2)O), and end-tidal CO2 (5 mmHg), while dynamic lung compliance decreased by 12 ml/cmH(2)O. Overall, the Trendelenburg position induced no significant hemodynamic or pulmonary changes. Conclusions: The effects of pneumoperitoneum significantly reduced dynamic lung compliance and increased peak inspiratory and plateau pressures. The Tredelenburg position did not change these parameters.
引用
收藏
页码:329 / 334
页数:6
相关论文
共 50 条
  • [41] Anaesthesia for laparoscopic kidney transplantation: Influence of Trendelenburg position and CO2 pneumoperitoneum on cardiovascular, respiratory and renal function
    Parikh, Beena Kandarp
    Shah, Veena R.
    Modi, Pranjal R.
    Butala, Beena P.
    Parikh, Geeta P.
    INDIAN JOURNAL OF ANAESTHESIA, 2013, 57 (03) : 253 - 258
  • [42] Effects of individualised positive end-expiratory pressure titration on respiratory and haemodynamic parameters during the Trendelenburg position with pneumoperitoneum A randomised crossover physiologic trial
    Boesing, Christoph
    Schaefer, Laura
    Schoettler, Jochen Johannes
    Quentin, Alena
    Beck, Grietje
    Thiel, Manfred
    Honeck, Patrick
    Kowalewski, Karl-Friedrich
    Pelosi, Paolo
    Rocco, Patricia R. M.
    Luecke, Thomas
    Krebs, Joerg
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2023, 40 (11) : 817 - 825
  • [43] Effect of pneumoperitoneum and trendelenburg position on intracranial pressure assessed using transcranial doppler - a prospective observational study
    Joseph, Anu
    ANESTHESIA AND ANALGESIA, 2021, 133 (3S_SUPPL): : 610 - 611
  • [44] Effect of Continuous Systemic Administration of Esmolol on Intraocular Pressure During Surgery in a Sustained Steep Trendelenburg Position
    Joo, Jin
    Kim, Jiyoung
    Lee, Jaemin
    JOURNAL OF GLAUCOMA, 2017, 26 (12) : 1068 - 1071
  • [45] EFFECTS OF PNEUMOPERITONEUM AND TRENDELENBURG POSITION ON INTRAOCULAR PRESSURE (IOP) IN ISOFLUORANE ANESTHETISED CATS
    de Souza, Arilton Teodoro
    Garcia, Debora de Oliveira
    Nishimura, Lilian Toshiko
    Magalhaes, Marcos Lucio
    Mattos-Junior, Ewaldo
    Paulino-Junior, Daniel
    Jorge, Adriana Torrecilhas
    Honsho, Cristiane dos Santos
    BIOSCIENCE JOURNAL, 2019, 35 (06): : 1899 - 1906
  • [46] Evaluation left ventricle Outflow in cats anesthetized submitted to pneumoperitoneum and Trendelenburg position
    Magalhaes, M. L.
    Nishimura, L. T.
    Souza, A. T.
    Magalhaes, C. F.
    Mattos Junior, E.
    Honsho, C. S.
    Paulino Junior, D.
    ARQUIVO BRASILEIRO DE MEDICINA VETERINARIA E ZOOTECNIA, 2017, 69 (05) : 1139 - 1144
  • [47] Effects of positive end-expiratory pressure on intracranial pressure during pneumoperitoneum and Trendelenburg position in a porcine model
    Bedirli, Nurdan
    Emmez, Gokcen
    Unal, Yusuf
    Tonge, Mehmet
    Emmez, Hakan
    TURKISH JOURNAL OF MEDICAL SCIENCES, 2017, 47 (05) : 1610 - 1615
  • [48] Effects of high positive end-expiratory pressure on haemodynamics and cerebral oxygenation during pneumoperitoneum in the Trendelenburg position
    Jo, Y. Y.
    Lee, J. Y.
    Lee, M. G.
    Kwak, H. J.
    ANAESTHESIA, 2013, 68 (09) : 938 - 943
  • [49] ENDOBRONCHIAL INTUBATION DURING UPPER ABDOMINAL LAPAROSCOPIC SURGERY IN THE REVERSE TRENDELENBURG POSITION
    BRIMACOMBE, JR
    ORLAND, H
    GRAHAM, D
    ANESTHESIA AND ANALGESIA, 1994, 78 (03): : 607 - 607
  • [50] Regional cerebral blood flow is compromised during robotic surgery in the Trendelenburg position, but not during surgery in the beach chair position: an observational study
    Oremek, Maximilian J.
    von Bargen, Anna
    Hoenemann, Jan-Niklas
    Diedrich, Andre
    Froehlich, Juerg
    Banat, Mohammed
    Krausewitz, Philipp
    Soehle, Martin
    Thudium, Marcus
    BRITISH JOURNAL OF ANAESTHESIA, 2024, 133 (04) : 896 - 898