POSTDURAL PUNCTURE HEADACHE - A COMPARISON BETWEEN THE 29-G VYGON AND 24-G SPROTTE NEEDLES

被引:0
|
作者
LIM, M
CROSS, GD
SOLD, M
机构
[1] UNIV WURZBURG,INST ANAESTHESIOL,JOSEF SCHNEIDER STR 2,W-8700 WURZBURG,GERMANY
[2] ST THOMAS HOSP,LONDON SE1 7EH,ENGLAND
来源
ANAESTHESIST | 1992年 / 41卷 / 09期
关键词
ATRAUMATIC SPINAL CANNULA; EXTRACORPOREAL SHOCKWAVE LITHOTRIPSY; POSTSPINAL PUNCTURE HEADACHE; PROSPECTIVE COMPARATIVE STUDY; SPINAL ANESTHESIA;
D O I
暂无
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Patients and methods. A randomised study was performed to compare the frequency of postdural puncture headache in 56 patients who underwent spinal anaesthesia for extra-corporeal shockwave lithotripsy using either a Sprotte 24 G (n = 28) or Vygon 29 G or Quincke type needle (n = 28). Frequency of headache was recorded in a similar group of 28 patients who received general anaesthesia. Results. Dural puncture was easier with the Sprotte 24 G cannula than with the less stable Quincke needle, as documented by a significantly shortened time for insertion of the cannula (4.6 +/- 2.6 vs 8.6 +/- 6.3 min, P < 0.005). The total frequency of post-operative headache was 57 % in the Vygon 29 G group and 25 % in the Sprotte 24 G group; 21 % of patients in the general anaesthesia group complained of headache. Frequency of postdural puncture headache, classified as being posture-related, was 25 % in the 29 G Vygon group, compared with 11 % in the 24 G Sprotte group (P = 0.148). When only moderate and severe postdural puncture headache was considered, there was a significant difference (25 % vs. 4 %; P = 0.026) in favour of the Sprotte cannula. Discussion and conclusions. Thus, the 24 G Sprotte needle was at least as effective as the 29 G Vygon needle, and there is a suggestion that the former is more effective in minimising the incidence of moderate or severe postdural puncture headache.
引用
收藏
页码:539 / 543
页数:5
相关论文
共 45 条
  • [31] Delayed postdural puncture headache with a 25G Whitacre needleCéphalées tardives après ponction rachidienne avec une aiguille de Withacre 25G
    Jean-Christian Sleth
    Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 2009, 56 (10): : 779 - 780
  • [32] EUS-Guided Pancreatic Biopsies: Comparison Between 22G and 25G Needles
    Ruiz-Obaldia, Jose Ricardo
    Giovannini, Mare
    Pesenti, Christian
    Da Silva, Patricia Marques
    Bories, Erwan
    Caillol, Fabrice
    Monges, G.
    Esterni, Bejamin
    GASTROINTESTINAL ENDOSCOPY, 2010, 71 (05) : AB292 - AB292
  • [33] A COMPARISON BETWEEN 4 HOURS AND 24 HOURS BED REST ON THE INCIDENCE OF POST LUMBAR PUNCTURE HEADACHE
    BEAVIS, RE
    COOK, PT
    DAVIES, MJ
    ANAESTHESIA AND INTENSIVE CARE, 1987, 15 (01) : 115 - 115
  • [34] Subjective Discomfort during Botulinumtoxin Injections Dependent on Injection Site and Needle Size: A Comparison Between 30G, 33G and 34G Needles
    Kaemmerer, Till A.
    Bertlich, Randolf
    Hartmann, Daniela
    Jakob, Mark
    Weiss, Bernhard G.
    Bertlich, Ines
    Ihler, Friedrich
    Wiggenhauser, Paul Severin
    Bertlich, Mattis
    AESTHETIC PLASTIC SURGERY, 2024, 48 (13) : 2528 - 2535
  • [35] POSTDURAL PUNCTURE HEADACHE IN YOUNG ORTHOPEDIC INPATIENTS - COMPARISON OF A 0.33 MM (29-GAUGE) QUINCKE-TYPE WITH A 0.7 MM (22-GAUGE) WHITACRE SPINAL NEEDLE IN 200 PATIENTS
    LYNCH, J
    ARHELGER, S
    KRINGSERNST, I
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1992, 36 (01) : 58 - 61
  • [36] A COMPARATIVE STUDY TO KNOW THE INCIDENCE OF POST-DURAL PUNCTURE HEADACHE FOLLOWING SUBARACHNOID BLOCK USING 27 G QUINCKE'S AND WHITACRE NEEDLES - A RANDOMIZED CLINICAL TRIAL
    Karigar, Shivanand Laxman
    Patil, Basvaraj
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2016, 5 (49): : 3236 - 3239
  • [37] Comparison of tissue volume yield between EUS FNA needles G22 and G25 using the stylet slow-pull technique
    Magsino, Ermil Ramilo
    Bondoc, Raiza Geires
    Ong, Evan
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2016, 31 : 339 - 339
  • [38] Endoscopic Ultrasound-Guided Fine Needle Aspiration of Pancreatic Lesions. Effectiveness and Comparison Between 19G and 22G Needles
    Coelho, Nelson
    Rodrigues, Carlos Renato F.
    Teixeira, Claudio R.
    Maia, Mauro
    Figueiredo, Luciana F.
    GASTROINTESTINAL ENDOSCOPY, 2015, 81 (05) : AB547 - AB547
  • [39] Comparison between 22G aspiration and 22G biopsy needles for EUS-guided sampling of pancreatic lesions: A meta-analysis
    Facciorusso, Antonio
    Bajwa, Harshvardhan Singh
    Menon, Kavitha
    Buccino, Vincenzo Rosario
    Muscatiello, Nicola
    ENDOSCOPIC ULTRASOUND, 2020, 9 (03) : 167 - +
  • [40] Postural post-dural puncture headache. A prospective randomised study and a mete-analysis comparing two different 0.40 mm OD (27 g) spinal needles
    Flaatten, H
    Felthaus, J
    Kuwelker, M
    Wiseborg, T
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2000, 44 (06) : 643 - 647