摘要
In our study, we quantitatively compared the hot particle dose calculated by our microcomputer Monte Carlo electron transport code, Eltran3, with the values calculated by the VARSKIN code. For a weightless source, the VARSKIN code overestimated the skin dose by 14% to 37% because the VARSKIN code is based on the data table for point sources in an unbounded medium. Five Co-60 hot particles were measured in the current and pulse mode operations of an ion-implanted silicon detector. The measurements were converted to skin dose rates and compared by use of Eltran3 and VARSKIN calculations. Measured values of the skin dose rates for four of the five hot particles agreed well with expected values. The skin dose rate per kBq of the four hot particles ranged from 0.70 to 0.85 mGy h-1 kBq-1. One of the five hot particles showed the presence of a pure beta-emitting radionuclide, which was not detected through gamma-ray measurements.
引用
收藏
页码:843 / 848
页数:6
相关论文
共 50 条
  • [11] Influence of Statistical Uncertainty On Monaco Monte-Carlo Dose Calculation
    Sharma, S.
    Subramani, V.
    Kumar, P.
    Gopishankar, N.
    Bhaskar, S.
    Pathy, S.
    Thulkar, S.
    Chander, S.
    MEDICAL PHYSICS, 2017, 44 (06) : 2920 - 2920
  • [12] MONTE-CARLO CALCULATION OF INTEGRAL RADIATION-DOSE IN XEROMAMMOGRAPHY
    DANCE, DR
    PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (01): : 25 - 37
  • [13] MONTE-CARLO EIGENVALUE CALCULATION
    BROCKWAY, D
    SORAN, P
    WHALEN, P
    LECTURE NOTES IN PHYSICS, 1985, 240 : 378 - 387
  • [14] MONTE-CARLO CALCULATION OF SODIUM IODIDE SCINTILLATION DETECTOR RESPONSE FUNCTION
    ODELL, AA
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1971, 14 (02): : 914 - &
  • [15] SIMULATION OF HG12 DETECTOR RESPONSES BY A MONTE-CARLO CALCULATION
    COUPAT, B
    FOURNIER, JP
    SILGA, M
    OMALY, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 260 (01): : 225 - 238
  • [16] SIGNAL-TO-BACKGROUND IN EPMA - MEASUREMENT AND MONTE-CARLO CALCULATION
    STARY, V
    MIKROCHIMICA ACTA, 1994, 114 : 463 - 474
  • [17] A MONTE-CARLO PARTICLE MODEL STUDY OF HOT-ELECTRON INJECTION
    MOGLESTUE, C
    PHYSICA B & C, 1985, 129 (1-3): : 552 - 556
  • [18] Phantoms in particle therapy to verify Monte Carlo dose calculation
    Wohlfahrt, P.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S363 - S364
  • [19] MONTE-CARLO CALCULATION OF NEUTRAL PARTICLE-TRANSPORT IN POLOIDAL DIVERTORS
    HEIFETZ, D
    POST, DE
    PETRAVIC, M
    WEISHEIT, J
    BATEMAN, G
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1980, 25 (08): : 1033 - 1033
  • [20] Validation of Monte-Carlo Proton Dose Calculation for Real Tissue Samples
    Wang, H.
    Wu, J.
    Zhang, R.
    Baer, E.
    Geng, C.
    Jee, K.
    Sharp, G.
    Paganetti, H.
    Tang, J.
    Lu, H.
    MEDICAL PHYSICS, 2017, 44 (06)