PULMONARY-HYPERTENSION - PULMONARY FLOW QUANTIFICATION AND FLOW PROFILE ANALYSIS WITH VELOCITY-ENCODED CINE MR IMAGING

被引:130
|
作者
KONDO, C
CAPUTO, GR
MASUI, T
FOSTER, E
OSULLIVAN, M
STULBARG, MS
GOLDEN, J
CATTERJEE, K
HIGGINS, CB
机构
[1] UNIV CALIF SAN FRANCISCO, DEPT RADIOL, BOX 0628, SAN FRANCISCO, CA 94143 USA
[2] UNIV CALIF SAN FRANCISCO, DEPT MED, SAN FRANCISCO, CA 94143 USA
关键词
BLOOD; FLOW DYNAMICS; HYPERTENSION; PULMONARY; LUNG; MR; US;
D O I
10.1148/radiology.183.3.1584932
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Velocity-encoded cine magnetic resonance (MR) imaging provides two-dimensional velocity maps of a cross-sectional area of a vessel. Pulmonary flow and flow patterns in the main pulmonary artery were analyzed with velocity-encoded cine MR imaging and Doppler echocardiography in 10 patients with pulmonary hypertension (PH), one patient with a dilated main pulmonary artery, and 10 healthy subjects, and these findings were compared. Peak systolic velocity measured with velocity-encoded cine MR imaging was similar to that measured with Doppler echocardiography in healthy subjects and in patients with PH. Velocity-encoded cine MR imaging demonstrated substantial differences in velocity across the vascular lumen in PH. The flow pattern in healthy subjects was different than that in patients with PH; the latter had lower peak systolic velocity and greater retrograde flow after middle to late systole. The retrograde flow observed in patients with PH reflected hemodynamic events, since it was inversely proportional to pulmonary flow volume and directly proportional to pulmonary resistance and cross-sectional area of the vessel. Velocity-encoded cine MR imaging demonstrates an inhomogeneous flow profile in PH and may serve as a noninvasive method to estimate pulmonary vascular resistance.
引用
收藏
页码:751 / 758
页数:8
相关论文
共 50 条
  • [31] Quantification of regional pulmonary flow with99mTc-MAA SPECT and cine phase contrast MR imaging
    Hisato Osada
    Kikuo Machida
    Norinari Honda
    Annals of Nuclear Medicine, 2002, 16 : 423 - 429
  • [32] Quantification of regional pulmonary flow with 99mTc-MAA SPECT and cine phase contrast MR imaging
    Osada, H
    Machida, K
    Honda, N
    ANNALS OF NUCLEAR MEDICINE, 2002, 16 (06) : 423 - 429
  • [33] Velocity-encoded, phase-difference cine MRI measurements of coronary artery flow: Dependence of flow accuracy on the number of cine frames
    Clarke, GD
    Hundley, WG
    McColl, RW
    Eckels, R
    Smith, D
    Chaney, C
    Li, HF
    Peshock, RM
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (05): : 733 - 742
  • [34] Flussquantifizierung in Koronar- und Bypass- gefäßen mit der MR-PhasenkontrasttechnikAssessment of flow quantification in coronary bypass grafts and coronary arteries with velocity-encoded cine MR imaging
    K.-F. Kreitner
    T. Voigtländer
    T. Wittlinger
    M. Dahm
    P. Kalden
    J. Meyer
    M. Thelen
    Der Radiologe, 2000, 40 : 143 - 149
  • [35] AORTIC-VALVE PRESSURE-GRADIENTS IN PATIENTS WITH AORTIC-VALVE STENOSIS - QUANTIFICATION WITH VELOCITY-ENCODED CINE MR IMAGING
    EICHENBERGER, AC
    JENNI, R
    VONSCHULTHESS, GK
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (05) : 971 - 977
  • [36] Arterial, Venous, and Cerebrospinal Fluid Flow: Simultaneous Assessment with Bayesian Multipoint Velocity-encoded MR Imaging
    Knobloch, Verena
    Binter, Christian
    Kurtcuoglu, Vartan
    Kozerke, Sebastian
    RADIOLOGY, 2014, 270 (02) : 566 - 573
  • [37] Flow velocity patterns in the pulmonary artery and pulmonary hypertension
    Raymond Hu
    Claude Tousignant
    Robert Chen
    Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 2012, 59 : 716 - 719
  • [38] Evaluation of flow volume and flow patterns in the patent false lumen of chronic aortic dissections using velocity-encoded cine magnetic resonance imaging
    Inoue, T
    Watanabe, S
    Sakurada, H
    Ono, K
    Urano, M
    Hijikata, Y
    Saito, I
    Masuda, Y
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 2000, 64 (10): : 760 - 764
  • [39] Flow velocity patterns in the pulmonary artery and pulmonary hypertension
    Hu, Raymond
    Tousignant, Claude
    Chen, Robert
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2012, 59 (07): : 716 - 719
  • [40] Four-dimensional velocity-encoded magnetic resonance imaging improves blood flow quantification in patients with complex accelerated flow
    Nordmeyer, Sarah
    Riesenkampff, Eugenie
    Messroghli, Daniel
    Kropf, Siegfried
    Nordmeyer, Johannes
    Berger, Felix
    Kuehne, Titus
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 37 (01) : 208 - 216