Volumetric modulated arc therapy for synchronous bilateral whole breast irradiation - A case study

被引:30
|
作者
Seppala, Jan [1 ]
Heikkila, Janne [1 ]
Myllyoja, Kimmo [1 ]
Koskela, Kristiina [1 ]
机构
[1] Kuopio Univ Hosp, Canc Ctr, POB 100, FI-70029 Kuopio, Finland
关键词
Radiotherapy; Bilateral breast cancer; VMAT; Field overlapping; Hotspots;
D O I
10.1016/j.rpor.2015.05.011
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The treatment planning of bilateral breast irradiation (BBI) is a challenging task. The overlapping of tangential fields is usually unavoidable without compromising the target coverage. The purpose of this study was to investigate the technical feasibility and benefits of a single isocentre volumetric modulated arc therapy (VMAT) in BBI. Methods and materials: Two women with bilateral breast cancer were included in this case study. The first patient (Pat#1) underwent a bilateral breast-conserving surgery and sentinel lymph node biopsy. The second patient (Pat#2) underwent a bilateral ablation and axillary lymph node dissection. Planning target volumes (PTV) and organs at risk were delineated on CT images. VMAT plans were created with four (two for both sides, Pat#1) or two (one for each breast, Pat#2) separate VMAT fields. Subsequently, traditional tangential field plans were generated for each patient and the dosimetric parameters were compared. Results: The treatment times of the patients with VMAT were less than 15 min with daily CBCT imaging. When compared to the standard tangential field technique, the VMAT plans improved the PTV dose coverage and dose homogeneity with improved sparing of lungs and heart. With traditional field arrangement, the overlapping of the tangential fields was inevitable without significantly compromising the target coverage, whereas with VMAT the hotspots were avoided. The patients were treated with the VMAT technique and no acute skin toxicity was observed with either of the patients. Conclusions: A single isocentre VMAT technique has been implemented clinically for BBI. With the VMAT techniques, the dose delivery was quick and the hotspots in the field overlapping areas were avoided. The PTV dose coverage was superior in VMAT plans when compared with conventional tangential technique plans. (C) 2015 Greater Poland Cancer Centre. Published by Elsevier Sp. z o.o. All rights reserved.
引用
收藏
页码:398 / 402
页数:5
相关论文
共 50 条
  • [41] Feasibility study of volumetric modulated arc therapy with Halcyon™ linac for total body irradiation
    Takuya Uehara
    Hajime Monzen
    Mikoto Tamura
    Masahiro Inada
    Masakazu Otsuka
    Hiroshi Doi
    Kenji Matsumoto
    Yasumasa Nishimura
    Radiation Oncology, 16
  • [42] Considerations in Bilateral Lung Treatment Planning With Volumetric Modulated Arc Therapy
    Song, Y.
    Mueller, B. A.
    Laguna, J.
    Obcemea, C. H.
    Saleh, Z.
    Tang, X.
    Both, S.
    Mychalczak, B. R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E684 - E684
  • [43] Volumetric Modulated Arc Therapy
    Shepard, D.
    Popple, R.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [44] Dosimetric Comparision of Coplanar versus Noncoplanar Volumetric Modulated Arc Therapy for Treatment of Bilateral Breast Cancers
    Bharati, Avinav
    Rath, Satyajeet
    Khurana, Rohini
    Rastogi, Madhup
    Mandal, Susama R.
    Gandhi, Ajeet Kumar
    Hadi, Rahat
    Srivastava, Anoop K.
    Mishra, Surendra Prasad
    JOURNAL OF MEDICAL PHYSICS, 2023, 48 (03) : 252 - 258
  • [45] Dosimetric comparison of helical tomotherapy, volumetric-modulated arc therapy, intensity-modulated radiotherapy, and field-in-field technique for synchronous bilateral breast cancer
    Cheng, Hao-Wen
    Chang, Chih-Chieh
    Shiau, An-Cheng
    Wang, Ming-Hua
    Tsai, Jo-Ting
    MEDICAL DOSIMETRY, 2020, 45 (03) : 271 - 277
  • [46] Volumetric Modulated Arc Therapy
    Shepard, D.
    Popple, R.
    MEDICAL PHYSICS, 2012, 39 (06) : 3858 - 3858
  • [47] A Dosimetric Comparison Between Volumetric Modulated Arc and 3D Treatment Plans for Synchronous Bilateral Breast Patients
    Levin, D.
    Shekel, E.
    Epstein, D.
    Tova, Y.
    Zalmanov-Faermann, S.
    Pfeffer, R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S750 - S751
  • [48] The role of volumetric modulated arc therapy in left breast cancer
    Cheung, E. Y. W.
    ANNALS OF ONCOLOGY, 2022, 33 : S181 - S181
  • [49] Volumetric modulated arc therapy applied to synchronous bilateral breast cancer radiotherapy: dosimetric study on deep inspiration breath hold versus free breathing set up
    Gaudino, D.
    Cima, S.
    Frapolli, M.
    Daniele, D.
    Muoio, B.
    pesce, G. A.
    Martucci, F.
    Azinwi, N. C.
    Bosetti, D.
    Bellesi, L.
    Casiraghi, M.
    Piliero, M. A.
    Pupillo, F.
    Presilla, S.
    Richetti, A.
    Valli, M.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2018, 4 (04):
  • [50] Dosimetric study of 3-dimensional conformal radiotherapy, electronic compensator technique, intensity modulated radiation therapy, and volumetric arc therapy in whole-breast irradiation.
    Nantavithya, Chonnipa
    JOURNAL OF CLINICAL ONCOLOGY, 2015, 33 (28)