Electrode Characteristics of Non-contact Electrocardiographic Measurement

被引:4
|
作者
Mathias, Dakurah Naangmenkpeong [1 ]
Kim, Sung-Il [1 ]
Park, Jae-Soon [1 ]
Joung, Yeun-Ho [1 ]
Choi, Won Seok [2 ]
机构
[1] Hanbat Natl Univ, Dept Elect & Control Engn, Taejon 305719, South Korea
[2] Hanbat Natl Univ, Dept Elect Engn, Taejon 305719, South Korea
关键词
Electrocardiogram; Electrophysiological; Bio-potential; Capacitive electrodes; Capacitive coupling;
D O I
10.4313/TEEM.2015.16.1.42
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The ability to take electrocardiographic measurements while performing our daily activities has become the people-choice for modern age vital sign sensing. Currently, wet and dry ECG electrodes are known to pose threats like inflammations, allergic reactions, and metal poisoning due to their direct skin interaction. Therefore, the main goal in this work is to implement a very small ECG sensor system with a capacitive coupling, which is able to detect electrical signals of heart at a distance without the conductive gel. The aim of this paper is to design, implement, and characterize the contactless ECG electrodes. Under a careful consideration of factors that affect a capacitive electrode functional integrity, several different sizes of ECG electrodes were designed and tested with a pilot ECG device. A very small cotton-insulated copper tape electrode (2.324 cm(2)) was finally attained that could detect and measure bioelectric signal at about 500 um of distance from the subject's chest.
引用
收藏
页码:42 / 45
页数:4
相关论文
共 50 条
  • [21] AUTOMATIC NON-CONTACT SHAFT MEASUREMENT
    DASSLER, HU
    WERKSTATTSTECHNIK ZEITSCHRIFT FUR INDUSTRIELLE FERTIGUNG, 1988, 78 (10): : 583 - 587
  • [22] Non-contact uplift measurement at overhead contact lines
    Hietzge, Jochen
    Stephan, Arnd
    eb - Elektrische Bahnen, 2007, 105 (4-5): : 276 - 279
  • [23] A non-contact measurement of the roughness of textile fabrics
    Bueno, MA
    Durand, B
    Renner, M
    EXPERIMENTAL TECHNIQUES, 2000, 24 (02) : 23 - 27
  • [24] A micro sensor for non-contact temperature measurement
    Li, XP
    Chan, WF
    MICROMACHINING AND MICROFABRICATION, 2000, 4230 : 66 - 75
  • [25] Balanced Non-contact Connector for PIM Measurement
    Murofushi, Ryunosuke
    Kuga, Nobuhiro
    Hanayama, Eiji
    2020 INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION (ISAP), 2021, : 197 - 198
  • [26] Wearable Monitoring System Based on Non-Contact Electrode
    Liu, Jihong
    Chen, Yuanjin
    Wu, Qilong
    Zhou, Yanfeng
    Qiao, Tianrun
    Sun, Bangke
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2019, 124 : 33 - 34
  • [27] NON-CONTACT MEASUREMENT OF SCULPTURED SURFACE OF ROTATION
    Zhang GuoxiongLiu ShuguiQiu ZurongYu FushengNaYonglinLeng ChanglinState Key Laboratory of PrecisionMeasuring Technology and Instruments
    Chinese Journal of Mechanical Engineering, 2004, (04) : 571 - 574
  • [28] Non-contact measurement of thermal diffusivity in tissue
    Telenkov, SA
    Youn, JI
    Goodman, DM
    Welch, AJ
    Milner, TE
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (02): : 551 - 558
  • [29] Non-contact speed measurement of solid surfaces
    Engelberg, T.
    Vom Stein, D.
    Zeitler, R.
    Technisches Messen TM, 64 (10):
  • [30] Non-contact OEM color measurement with JENCOLOR
    不详
    SENSOR REVIEW, 2010, 30 (01) : 80 - 81