STAGING OF URINARY-BLADDER NEOPLASMS WITH MR IMAGING - IS GD-DTPA HELPFUL

被引:23
|
作者
NEUERBURG, JM [1 ]
BOHNDORF, K [1 ]
SOHN, M [1 ]
TEUFL, F [1 ]
GUNTHER, RW [1 ]
机构
[1] UNIV AACHEN,FAC MED,DEPT UROL,AACHEN,GERMANY
关键词
BLADDER; NEOPLASMS; GADOLINIUM; CONTRAST MEDIA; MAGNETIC RESONANCE IMAGING;
D O I
10.1097/00004728-199109000-00010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study was performed to investigate whether intravenous administration of Gd-DTPA can improve the accuracy of MR imaging in the detection and staging of bladder neoplasms. In 68 patients with suspected urinary bladder neoplasms, MR examinations were performed with TI-weighted SE sequences before and after intravenous administration of Gd-DTPA. The findings were compared with surgical staging using the TNM classification. Overall staging accuracy of contrast enhanced MR was 46%; if stages Ta-T3a were combined into one group, the accuracy was 69%. Accuracy was low (19%) in tumors without muscular bladder wall invasion (Ta). In cases with extravesical spread (greater-than-or-equal-to T3b), the accuracy of staging was 87%. Contrast enhanced MR detected extravesical extension of tumor with a sensitivity of 93% and a specificity of 95%. Contrast enhancement increased the sensitivity for detection of urinary bladder neoplasms from 70% on precontrast TI-weighted scans to 79% on postcontrast scans. In comparison with T2-weighted scans, the Gd-DTPA enhanced T1-weighted scans had better image quality and lower acquisition times.
引用
收藏
页码:780 / 786
页数:7
相关论文
共 50 条
  • [41] STATIC AND DYNAMIC GD-DTPA ENHANCED MR-IMAGING OF THE PANCREAS
    SITTEK, H
    HEUCK, AF
    FOLSING, C
    GIESEKE, J
    REISER, M
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1995, 162 (05): : 396 - 403
  • [42] GD-DTPA ENHANCED MR IMAGING OF INTRACRANIAL VASCULAR-LESIONS
    HENKES, H
    SCHOERNER, W
    BITTNER, R
    FELIX, R
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1989, 10 (04) : 903 - 903
  • [43] OBSTRUCTIVE NEPHROPATHY - EVALUATION WITH DYNAMIC GD-DTPA ENHANCED MR IMAGING
    SEMELKA, RC
    HRICAK, H
    TOMEI, E
    FLOTH, A
    STOLLER, M
    RADIOLOGY, 1990, 175 (03) : 797 - 803
  • [44] STURGE-WEBER SYNDROME - CRANIAL MR IMAGING WITH GD-DTPA
    BENEDIKT, RA
    BROWN, DC
    WALKER, R
    GHAED, VN
    MITCHELL, M
    GEYER, CA
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1993, 14 (02) : 409 - 415
  • [45] MR Imaging of the Cochlear Modiolus after Intratympanic Administration of Gd-DTPA
    Kawai, Hisashi
    Naganawa, Shinji
    Ishihara, Shunichi
    Sone, Michihiko
    Nakashima, Tsutomu
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2010, 9 (01) : 23 - 29
  • [46] COMPARISON OF GD-BOPTA WITH GD-DTPA IN MR IMAGING OF RAT-LIVER
    PAVONE, P
    PATRIZIO, G
    BUONI, C
    TETTAMANTI, E
    PASSARIELLO, R
    MUSU, C
    TIRONE, P
    FELDER, E
    RADIOLOGY, 1990, 176 (01) : 61 - 64
  • [47] MR-IMAGING WITH GD-DTPA IN CARCINOMAS OF TONGUE, OROPHARYNX AND HYPOPHARYNX
    EINSPIELER, R
    EBNER, F
    POSAWETZ, W
    RANNER, G
    FLUCKIGER, F
    LAMMER, J
    EUROPEAN JOURNAL OF RADIOLOGY, 1991, 13 (01) : 21 - 26
  • [48] RECURRENT MEDULLOBLASTOMA - FREQUENCY OF TUMOR ENHANCEMENT ON GD-DTPA MR IMAGING
    ROLLINS, N
    MENDELSOHN, D
    MULNE, A
    BARTON, R
    DIEHL, J
    REYES, N
    SKLAR, F
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1990, 11 (03) : 583 - 587
  • [49] DYNAMIC GD-DTPA - ENHANCED MR IMAGING OF THE KIDNEY - EXPERIMENTAL RESULTS
    CHOYKE, PL
    FRANK, JA
    GIRTON, ME
    INSCOE, SW
    CARVLIN, MJ
    BLACK, JL
    AUSTIN, HA
    DWYER, AJ
    RADIOLOGY, 1989, 170 (03) : 713 - 720
  • [50] GD-DTPA ENHANCEMENT OF THE CISTERNAL PORTION OF THE OCULOMOTOR NERVE ON MR IMAGING
    MARK, AS
    BLAKE, P
    ATLAS, SW
    ROSS, M
    BROWN, D
    KOLSKY, M
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1992, 13 (05) : 1463 - 1470