Applying Lean Methods to Improve Quality and Safety in Surgical Sterile Instrument Processing

被引:38
|
作者
Blackmore, C. Craig [1 ]
Bishop, Robbi [2 ]
Luker, Samuel
Williams, Barbara L. [3 ]
机构
[1] Virginia Mason Med Ctr, Ctr Hlth Serv Res, Seattle, WA 98101 USA
[2] Kaizen Promot Off, Seattle, WA USA
[3] Ctr Hlth Serv Res, Seattle, WA USA
来源
JOINT COMMISSION JOURNAL ON QUALITY AND PATIENT SAFETY | 2013年 / 39卷 / 03期
关键词
D O I
10.1016/S1553-7250(13)39014-X
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: Surgical instrument processing is critical to safe, high-quality surgical care but has received little attention in the medical literature. Typical hospitals have inventories in the tens of thousands of surgical instruments organized into thousands of instrument sets. The use of these instruments for multiple procedures per day leads to millions of instrument sets being reprocessed yearly in a single hospital. Errors in the processing of sterile instruments may lead to increased operative times and costs, as well as potentially contributing to surgical infections and perioperative morbidity. Methods: At Virginia Mason Medical Center (Seattle), a quality monitoring approach was developed to identify and categorize errors in sterile instrument processing, through use of a Daily Defect Sheet. Lean methods were used to improve the quality of surgical instrument processing through redefining operator roles, alteration of the workspace, mistake-proofing, quality monitoring, staff training, and continuous feedback. To study the effectiveness of the quality improvement project, a before/after comparison of prospectively collected sterile processing error rates during a 37-month time frame was performed. Results: Before the intervention, instrument processing errors occurred in 3.0% of surgical cases, decreasing to 1.5% at the final follow-up (p < .001). Improvements were observed in multiple categories of error types, particularly the assembly errors of packaging (from 0.66 to 0.24 errors per hundred cases, p = .004), and foreign objects (0.17 to 0.02 errors per hundred cases, p = .025). Conclusion: Surgical instrument processing errors are a barrier to the highest quality and safety in surgical care but are amenable to substantial improvement using Lean techniques.
引用
收藏
页码:99 / +
页数:8
相关论文
共 50 条
  • [21] Value Stream Mapping of the Pap Test Processing Procedure A Lean Approach to Improve Quality and Efficiency
    Michael, Claire W.
    Naik, Kalyani
    McVicker, Michael
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2013, 139 (05) : 574 - 583
  • [22] LEAN: INTRODUCTION OF A QUALITY IMPROVEMENT CONCEPT TO IMPROVE EFFICIENCY WHILE MAINTAINING SAFETY IN PERCUTANEOUS NEPHROLITHOTOMY
    Fernandez, Nicolas
    Hannick, Jessica
    Escobar, Rebeca
    Serrano, Adolfo
    JOURNAL OF UROLOGY, 2020, 203 : E1046 - E1046
  • [23] Methods for pre-processing smartcard data to improve data quality
    Robinson, Steve
    Narayanan, Baskaran
    Toh, Nelson
    Pereira, Francisco
    TRANSPORTATION RESEARCH PART C-EMERGING TECHNOLOGIES, 2014, 49 : 43 - 58
  • [24] The ethics of using QI methods to improve health care quality and safety
    Baily, Mary Ann
    Bottrell, Melissa
    Lynn, Joanne
    Jennings, Bruce
    HASTINGS CENTER REPORT, 2006, 36 (04) : S1 - S40
  • [25] Dissemination of Toyota methods to improve quality and patient safety in pap testing
    Vrbin, C. M.
    Andrew-Jaja, C.
    Grzybicki, D. M.
    Condel, J. L.
    Carter, G.
    Raab, S. S.
    MODERN PATHOLOGY, 2007, 20 : 86A - 86A
  • [26] Use of efficient drying methods to improve the safety and quality of dried fig
    Villalobos, M. C.
    Serradilla, M. J.
    Martin, A.
    Ruiz-Moyano, S.
    Casquete, R.
    Hernandez, A.
    Cordoba, M. G.
    JOURNAL OF FOOD PROCESSING AND PRESERVATION, 2019, 43 (01)
  • [27] Dissemination of Toyota methods to improve quality and patient safety in pap testing
    Vrbin, C. M.
    Andrew-Jaja, C.
    Grzybicki, D. M.
    Condel, J. L.
    Carter, G.
    Raab, S. S.
    LABORATORY INVESTIGATION, 2007, 87 : 86A - 86A
  • [28] Applying Lean Kaizen to improve timely CT scan appointments for oncology patients in a safety-net hospital.
    Ho, Brian
    Epistola, Raisa
    Leong, Sally
    Ali, Sana
    Germono, Rachel
    Ranada, Denise
    Kummerfeldt, Christopher
    Patel, Vrunda
    Berbano, Annette
    Berbano, Annette
    Kannampuzha, Minni
    Celles, Larissa
    Pena, Adriana
    Balderas, Leslie
    Ellis, Sharon
    Abarca, Brenda Martinez
    Gutierrez, Griselda
    Shim, John
    Lee, Jennifer Minkyoung
    Yeh, James Jen-Chi
    JOURNAL OF CLINICAL ONCOLOGY, 2022, 40 (16) : E18627 - E18627
  • [29] How I Do It: Teaching and Applying Qualitative Methods to Improve Surgical Simulation Design and Implementation
    Clark, Lou
    Weaver, Lauren
    Floersch, Eugene
    Remskar, Mojca
    Brunsvold, Melissa
    Woll, Anne
    JOURNAL OF SURGICAL EDUCATION, 2025, 82 (05)
  • [30] Integration of Emerging Biomedical Technologies in Meat Processing to Improve Meat Safety and Quality
    Ravensdale, Joshua T.
    Coorey, Ranil
    Dykes, Gary A.
    COMPREHENSIVE REVIEWS IN FOOD SCIENCE AND FOOD SAFETY, 2018, 17 (03): : 615 - 632