The Analysis of Different Approaches Related to the Measurement Uncertainty in Biomedical Calibration

被引:0
|
作者
Karagoz, Irfan [1 ]
Cecelioglu, Serkan [1 ]
机构
[1] Gazi Univ, Fac Engn & Architecture, Elect Elect Engn Dept, TR-06570 Ankara, Turkey
来源
GAZI UNIVERSITY JOURNAL OF SCIENCE | 2007年 / 20卷 / 03期
关键词
Biomedical calibration; Measurement uncertainty; t-distribution; z-distribution;
D O I
暂无
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
As a result of the calculation of expanded uncertainty, the measurement uncertainty defines an interval within which the measurand lies. Expanded uncertainty is generally calculated by using z-distribution in conjunction with coverage factor k. But, by using z-distribution, correctly finding the interval which the measurand lies within, with a specified confidence level, requires too many measurements which must be done repeatedly. In an ideal case, the number of measurements must approach infinity. Since this is not the case in practice, if the number of measurements is small, using Student's factor t(v,p) instead of coverage factor k results in the definition of a relatively wider interval and more accurate results. This situation is shown, as a result of an analysis done on a biomedical system, by calculating the measurement uncertainty and the interval within which the measurand lies in a confidence level of 95%, comparing two different approaches.
引用
收藏
页码:61 / 67
页数:7
相关论文
共 50 条
  • [31] MEASUREMENT UNCERTAINTY EVALUATION ASSOCIATED WITH CALIBRATION FUNCTIONS
    Cox, M. G.
    Forbes, A. B.
    Harris, P. M.
    Smith, I. M.
    XIX IMEKO WORLD CONGRESS: FUNDAMENTAL AND APPLIED METROLOGY, PROCEEDINGS, 2009, : 2346 - 2351
  • [32] Evaluation of measurement uncertainty for thermometers with calibration equations
    Chiachung Chen
    Accreditation and Quality Assurance, 2006, 11 : 75 - 82
  • [33] Reflectometer Calibration for Net Power Measurement and Uncertainty
    Morioka, Takehiro
    2020 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM), 2020,
  • [34] Calibration method of microscope and its measurement uncertainty
    Bao Jian-ping
    Wang Hui-sheng
    Zhang Xiao-fei
    Third International Symposium on Precision Mechanical Measurements, Pts 1 and 2, 2006, 6280 : U706 - U712
  • [35] The Measurement Uncertainty Evaluation of Yaw Sensor Calibration
    Tipsuwanporn, Vittaya
    Chinchusak, Wanchai
    Jaturunruangsri, Supaporn
    2016 16TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS (ICCAS), 2016, : 555 - 558
  • [36] Evaluation of measurement uncertainty for thermometers with calibration equations
    Chen, CC
    ACCREDITATION AND QUALITY ASSURANCE, 2006, 11 (1-2) : 75 - 82
  • [37] Internet-enabled calibration:: An analysis of different topologies and a comparison of two different approaches
    Sand, Asmund
    Stevens, Michael
    Parkin, Graerne
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2007, 56 (05) : 1986 - 1991
  • [38] Analysis of different maximum a posteriori estimation approaches for interferometric parameter calibration
    Knedlik, S
    Loffeld, O
    IGARSS 2000: IEEE 2000 INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, VOL I - VI, PROCEEDINGS, 2000, : 773 - 775
  • [39] Analysis of Uncertainty in Calibration Curves
    Machado, V.
    Sundin, M. S.
    VI LATIN AMERICAN CONGRESS ON BIOMEDICAL ENGINEERING (CLAIB 2014), 2014, 49 : 730 - 733
  • [40] Polarimetric Calibration - a comparison of different approaches
    Schimpf, Hartmut
    Fuchs, Hans-Hellmuth
    2008 PROCEEDINGS INTERNATIONAL RADAR SYMPOSIUM, 2008, : 152 - 155