DETERMINATION OF GERMANIUM BY POTENTIOMETRIC STRIPPING ANALYSIS AND ADSORPTION POTENTIOMETRIC STRIPPING ANALYSIS

被引:3
|
作者
FENG, DX
YANG, PH
YANG, ZL
机构
[1] Department of Chemistry, Jinan University, Guangzhou
关键词
D O I
10.1016/0039-9140(91)80301-F
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Potentiometric stripping analysis was applied to determination of germanium(IV) in 0.2M NH3-NH4Cl (pH 8.4) buffer solution at -1.8 V (vs. Ag/AgCl), with dissolved oxygen or Hg(II) as oxidant. The sensitivity was 8.5 x 10(-9) M in the presence of 2.0 x 10(-5) M Hg(II) with plating for 15 min after deaeration for 20 min. Cyclic voltammetry revealed that Ge(IV) --> Ge at the surface of the mercury-film electrode in a one-step irreversible reduction reaction, and the Ge at the electrode was oxidized by dissolved oxygen in the solution. The presence of complexing agents such as Alizarin Red (ARS), which forms a Ge(IV) complex adsorbed at the electrode, improved the sensitivity by one order of magnitude. The presence of adsorption was revealed by the temperature coefficient, the electrocapillary curve and cyclic voltammetry. Ge-containing samples were analysed by the proposed methods and agreement with the results obtained by other methods was excellent.
引用
收藏
页码:1493 / 1498
页数:6
相关论文
共 50 条
  • [21] POTENTIOMETRIC STRIPPING ANALYSIS IN FLOW CELLS
    ANDERSON, L
    JAGNER, D
    JOSEFSON, M
    ANALYTICAL CHEMISTRY, 1982, 54 (08) : 1371 - 1376
  • [22] Virtual instrument for potentiometric stripping analysis
    Stastny, M
    Nepozitek, J
    CHEMICKE LISTY, 1996, 90 (08): : 527 - 533
  • [23] COMPUTERIZED FLOW POTENTIOMETRIC STRIPPING ANALYSIS
    JAGNER, D
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1983, 2 (03) : 53 - 56
  • [24] METAL INTERFERENCES IN POTENTIOMETRIC STRIPPING ANALYSIS
    PSAROUDAKIS, SV
    EFSTATHIOU, CE
    ANALYST, 1987, 112 (11) : 1587 - 1591
  • [25] POTENTIOMETRIC STRIPPING ANALYSIS .1.
    FEHER, Z
    KADAR, M
    PUNGOR, E
    MAGYAR KEMIAI FOLYOIRAT, 1983, 89 (01): : 1 - 7
  • [26] POTENTIOMETRIC STRIPPING ANALYSIS AT A STATIONARY ELECTRODE
    LABAR, C
    LAMBERTS, L
    ANALYTICA CHIMICA ACTA, 1981, 132 (DEC) : 23 - 33
  • [27] STUDIES ON FILM POTENTIOMETRIC STRIPPING ANALYSIS
    XIA, YH
    CHOU, TC
    MO, JY
    ANALYTICA CHIMICA ACTA, 1989, 222 (02) : 263 - 268
  • [28] POTENTIOMETRIC STRIPPING ANALYSIS .2.
    FEHER, Z
    PUNGOR, E
    NARAY, M
    MAGYAR KEMIAI FOLYOIRAT, 1984, 90 (08): : 361 - 366
  • [29] MICROCOMPUTER SYSTEM FOR POTENTIOMETRIC STRIPPING ANALYSIS
    GRANELI, A
    JAGNER, D
    JOSEFSON, M
    ANALYTICAL CHEMISTRY, 1980, 52 (13) : 2220 - 2223
  • [30] POTENTIOMETRIC STRIPPING ANALYSIS FOR LEAD IN URINE
    JAGNER, D
    DANIELSSON, LG
    AREN, K
    ANALYTICA CHIMICA ACTA, 1979, 106 (01) : 15 - 21