Mediated Amperometric Biosensor for the Determination of Ammonium

被引:0
|
作者
Abd Rahman, Samsulida [1 ]
Abdullah, Jaafar [1 ]
Sidek, Hamidah [1 ]
Azmi, Nur Ellina [1 ]
机构
[1] Sirim Berhad, Ind Biotechnol Res Ctr, 1 Persiaran Dato Menteri,POB 7035, Shah Alam 40911, Selangor, Malaysia
来源
ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY | 2012年 / 4卷 / 03期
关键词
Ammonium Biosensor; Glutamate Dehydrogenase; Diaphorase; Ferrocene Carboxaldehyde; Chitosan;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A mediated amperometric biosensor based on bi- layer glutamate dehydrogenase (GLDH)/diaphorase immobilized on screen printed carbon paste electrode (SPCE) for the determination of ammonium has been described. In this work the electrochemical oxidation of NADH was used as indicator reaction for the quantification of ammonium concentration. The use of ferrocene carboxaldehyde as an electron transfer mediator lowered the oxidation potential of NADH to + 0.4 V vs. Ag/AgCl. Parameter optimization improves the analytical performance of the biosensor within the linearity range of 2.5 mu M to 500 mu M with the detection limit of 2.5 mu M. The reproducibility of the fabricated biosensor was also evaluated and it was found to be good with a relative standard deviation (RSD) of 4.17% (n= 5). A good agreement with the Indothymol method was obtained for the measurement of ammonium in water samples.
引用
收藏
页码:262 / 276
页数:15
相关论文
共 50 条
  • [31] Amperometric determination of fish freshness by a hypoxanthine biosensor
    Shen, LQ
    Yang, LJ
    Peng, TZ
    JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE, 1996, 70 (03) : 298 - 302
  • [32] Amperometric biosensor for the determination of histamine in fish samples
    Perez, Sandra
    Bartroli, Jordi
    Fabregas, Esteve
    FOOD CHEMISTRY, 2013, 141 (04) : 4066 - 4072
  • [33] Prototype amperometric biosensor for sialic acid determination
    Marzouk, Sayed A. M.
    Ashraf, S. S.
    Al Tayyari, Khawla A.
    ANALYTICAL CHEMISTRY, 2007, 79 (04) : 1668 - 1674
  • [34] A CHEMICALLY MEDIATED AMPEROMETRIC BIOSENSOR FOR MONITORING EUBACTERIAL RESPIRATION
    RICHARDSON, NJ
    GARDNER, S
    RAWSON, DM
    JOURNAL OF APPLIED BACTERIOLOGY, 1991, 70 (05): : 422 - 426
  • [35] POLYPYRROLE-BASED AMPEROMETRIC BIOSENSOR FOR SULFITE DETERMINATION
    ADELOJU, SB
    SHAW, SJ
    WALLACE, GG
    ELECTROANALYSIS, 1994, 6 (10) : 865 - 870
  • [36] A nylon membrane based amperometric biosensor for polyphenol determination
    Narang, Jagriti
    Chauhan, Nidhi
    Singh, Anamika
    Pundir, C. S.
    JOURNAL OF MOLECULAR CATALYSIS B-ENZYMATIC, 2011, 72 (3-4) : 276 - 281
  • [37] Determination of salicylate in beverages and cosmetics by use of an amperometric biosensor
    Ehrendorfer, M
    Sontag, G
    Pittner, F
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1996, 356 (01): : 75 - 79
  • [38] An Amperometric Horseradish Peroxidase Inhibition Biosensor for the Determination of Phenylhydrazine
    Zhou-Sheng Yang
    Wei-Li Wu
    Xi Chen
    Yun-Chun Liu
    Analytical Sciences, 2008, 24 : 895 - 899
  • [39] Modelling of Amperometric Biosensor Used for Synergistic Substrates Determination
    Simelevicius, Dainius
    Baronas, Romas
    Kulys, Juozas
    SENSORS, 2012, 12 (04): : 4897 - 4917
  • [40] Amperometric Biosensor Coupled to Capillary Electrophoresis for Glucose Determination
    Gang Chen
    Yuting Wang
    Pengyuan Yang
    Microchimica Acta, 2005, 150 : 239 - 245