QUANTITATIVE INVESTIGATION OF CHARGE-TRAPPING EFFECTS ON RAMAN-SPECTRA ACQUIRED USING CHARGE-COUPLED-DEVICE (CCD) DETECTORS

被引:7
|
作者
LACY, WB [1 ]
ROWLEN, KL [1 ]
HARRIS, JM [1 ]
机构
[1] UNIV UTAH,SALT LAKE CITY,UT 84112
关键词
CHARGE-COUPLED DEVICE (CCD); SPECTROSCOPIC INSTRUMENTATION; RAMAN SPECTROSCOPY;
D O I
10.1366/0003702914335373
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Changes in spectral band parameters (width, center frequency, intensity) which arise from charge-trapping artifacts in the Thomson TH 7882 charge-coupled-device (CCD) detector are reported. These parameters are measured for a Raman scattering band of carbon tetrachloride with respect to CCD geometry (parallel vs. serial binning), in the presence and absence of preflash, vs. changes in integration time (variation in detected light level). The dependence of the spectral parameters on detector temperature was also measured. The degree of charge trapping and the charge transfer efficiency were estimated from the change in peak width and intensity vs. integration time, respectively, and were found to vary with detector temperature according to an Arrhenius relationship for the serial-binning geometry; from these results, the energy barriers to charge trapping and loss in the serial register were estimated. Practical guidelines for acquisition of binned spectra with this detector are suggested.
引用
收藏
页码:1598 / 1603
页数:6
相关论文
共 50 条
  • [31] AN EXPERIMENTAL-METHOD TO EXPLOIT THE PROPERTIES OF A CHARGE-COUPLED-DEVICE (CCD) FOR IMPROVED MEASUREMENTS OF DECAY CURVES IN BEAM-FOIL SPECTROSCOPY
    KAY, L
    SADLER, DA
    PHYSICA SCRIPTA, 1995, 51 (04): : 459 - 464
  • [32] UNIQUE OPTICS FOR RAMAN-SPECTROSCOPY USING CHARGE COUPLED DEVICE DETECTION
    PELLETIER, MJ
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1991, 202 : 35 - ANYL
  • [33] THE EFFECT OF CHARGE TRAPS ON RAMAN-SPECTROSCOPY USING A THOMSON-CSF CHARGE COUPLED DEVICE DETECTOR
    PEMBERTON, JE
    SOBOCINSKI, RL
    SIMS, GR
    APPLIED SPECTROSCOPY, 1990, 44 (02) : 328 - 330
  • [34] Effect on noise of intensity-axis correction of spectra recorded with charge-coupled device detectors
    Jones, JP
    Wambles, RE
    Mann, CK
    Vickers, TJ
    APPLIED SPECTROSCOPY, 2002, 56 (05) : 564 - 569
  • [35] ENHANCED DETECTION OF NORMAL RETINAL NERVE-FIBER STRIATIONS USING A CHARGE-COUPLED-DEVICE AND DIGITAL FILTERING
    RICHARDS, DW
    JANESICK, JR
    ELLIOT, ST
    DINGIZIAN, A
    VELTHUIZEN, R
    WEI, Q
    CLARKE, LP
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1993, 231 (10) : 595 - 599
  • [36] Traps spectroscopy of the Si3Ni4 layer using localized charge-trapping nonvolatile memory device
    Lusky, E
    Shacham-Diamand, Y
    Shappir, A
    Bloom, I
    Eitan, B
    APPLIED PHYSICS LETTERS, 2004, 85 (04) : 669 - 671
  • [37] Experimental Study on Damage Effect of Mid-Infrared Pulsed Laser on Charge Coupled Device (CCD) and HgCgTe Detectors
    Liu, Yang
    Zhou, Feng
    Wang, Yunzhe
    Zhang, Yin
    Zhang, Yunfeng
    Zheng, Hanyu
    Shao, Junfeng
    SENSORS, 2024, 24 (13)
  • [38] HIGH-SPEED DOCUMENT SCANNER USING CHARGE COUPLED DEVICE (CCD) IMAGE SENSORS
    MORI, M
    KONDO, I
    HORIE, M
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1983, 350 : 66 - 72
  • [39] POLYNOMIAL FILTERS FOR DATA SETS WITH OUTLYING OR MISSING OBSERVATIONS - APPLICATION TO CHARGE-COUPLED-DEVICE-DETECTED RAMAN-SPECTRA CONTAMINATED BY COSMIC-RAYS
    PHILLIPS, GR
    HARRIS, JM
    ANALYTICAL CHEMISTRY, 1990, 62 (21) : 2351 - 2357
  • [40] A LARGE-FORMAT HIGH-RESOLUTION AREA X-RAY-DETECTOR BASED ON A FIBEROPTICALLY BONDED CHARGE-COUPLED-DEVICE (CCD)
    TATE, MW
    EIKENBERRY, EF
    BARNA, SL
    WALL, ME
    LOWRANCE, JL
    GRUNER, SM
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1995, 28 : 196 - 205