ANALYSIS OF PRIMER RESIDUE FROM CCL BLAZER(R) LEAD-FREE AMMUNITION BY SCANNING ELECTRON-MICROSCOPY ENERGY-DISPERSIVE X-RAY

被引:0
|
作者
HARRIS, A [1 ]
机构
[1] MONTANA DEPT JUSTICE,DIV FORENS SCI,MISSOULA,MT
关键词
FORENSIC SCIENCE; GUNSHOP RESIDUE; PRIMER ANALYSIS;
D O I
暂无
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Traditional gunshot residue analysis is based on the detection of lead (Pb), barium (Ba) and antimony (Sb). CCI's recent development of a lead free centerfire primer for their Blazer(R) Lead Free ammunition presents a new challenge for forensic scientists since it does not contain lead, barium or antimony. Research presented here is the result of the analysis of this new primer by scanning electron microscopy/energy dispersive X-ray which involved analyzing CCI's lead free primer directly as well as the gunshot residue obtained by test firing a series of firearms using CCI's Blazer(R) Lead Free ammunition. Analysis of the residue from a fired primer determined that the only metal present was strontium; however, when the lead free ammunition is discharged in firearms previously fired using traditional primer ammunition, particles containing lead, barium and antimony were detected. These findings hold true for older firearms cleaned prior to testing as well as a ''new'' firearm that had only been test fired by the manufacturer.
引用
收藏
页码:27 / 30
页数:4
相关论文
共 50 条
  • [41] USE OF AN ENERGY DISPERSIVE X-RAY ANALYZER IN SCANNING ELECTRON MICROSCOPY
    ELAD, E
    SANDBORG, AO
    RUSS, JC
    VANGORP, T
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1970, NS17 (01) : 354 - +
  • [42] X-ray and Scanning Acoustic Microscopy Analysis on Lead-free Automotive Electronic Module
    Manukova, Aneliya
    Stephanov, Doychin
    Pencheva, Tamara
    2009 32ND INTERNATIONAL SPRING SEMINAR ON ELECTRONICS TECHNOLOGY, 2009, : 332 - +
  • [43] The study of silver nanoparticles by scanning electron microscopy, energy dispersive X-ray analysis and scanning tunnelling microscopy
    Puchalski, M.
    Dabrowski, P.
    Olejniczak, W.
    Krukowski, P.
    Kowalczyk, P.
    Polanski, K.
    MATERIALS SCIENCE-POLAND, 2007, 25 (02): : 473 - 478
  • [44] The characterisation of settled dust by scanning electron microscopy and energy dispersive X-ray analysis
    Shilton, V
    Giess, P
    Mitchell, D
    Williams, C
    URBAN AIR QUALITY - RECENT ADVANCES, PROCEEDINGS, 2002, : 237 - 246
  • [45] Energy dispersive X-ray analysis on an absolute scale in scanning transmission electron microscopy
    Chen, Z.
    D'Alfonso, A. J.
    Weyland, M.
    Taplin, D. J.
    Allen, L. J.
    Findlay, S. D.
    ULTRAMICROSCOPY, 2015, 157 : 21 - 26
  • [46] Examination of firearm gunpowders by scanning electron microscopy/energy dispersive X-ray analysis
    Burnett, Bryan R.
    Nunziata, Felice
    Gentile, Claudio
    JOURNAL OF FORENSIC SCIENCES, 2021, 66 (02): : 709 - 718
  • [47] Scanning electron microscopy/energy dispersive X-ray analysis in cement clinker research
    Sarkar, Shondeep L.
    World Cement, 1995, 26 (08):
  • [48] APPLICATION OF SCANNING ELECTRON-MICROSCOPY AND ENERGY-DISPERSIVE X-RAY-ANALYSIS TO THE SOLUTION BEHAVIOR OF ZN-INSULIN - PRECIPITATION PHENOMENA
    SALEMINK, PJM
    ELZERMAN, HJW
    STENFERT, JT
    GRIBNAU, TCJ
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1989, 7 (11) : 1261 - 1266
  • [49] SCANNING ELECTRON-MICROSCOPY AND ENERGY-DISPERSIVE X-RAY-ANALYSIS OF CORROSION PRODUCTS ON LOW-GOLD DENTAL CASTING ALLOYS
    SARKAR, NK
    JOURNAL OF DENTAL RESEARCH, 1980, 59 : 525 - 525