The electrical characteristics of a LPE n-type GaAs crystal have been fully measured. The experimental results were used to build a model, including the parametrization of the electric field inside the crystal, and to study the features of such material as a detector in view of a possible application for digital radiography. The predictions of a Monte Carlo based on this model are in very good agreement with the measured performances of this crystal when used as a detector for X-rays in the diagnostic energy range.
引用
收藏
页码:372 / 378
页数:7
相关论文
共 50 条
  • [41] Comparison of different GaAs detectors for X-ray digital radiography
    Bencivelli, W.
    Bertin, R.
    Bertolucci, E.
    Bottigli, U.
    D'Auria, S.
    Del Papa, C.
    Fantacci, M.E.
    Randaccio, P.
    Rosso, V.
    Stefanini, A.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1994, A338 (2-3) : 549 - 555
  • [42] COMPARISON OF DIFFERENT GAAS DETECTORS FOR X-RAY DIGITAL RADIOGRAPHY
    BENCIVELLI, W
    BERTIN, R
    BERTOLUCCI, E
    BOTTIGLI, U
    DAURIA, S
    DELPAPA, C
    FANTACCI, ME
    RANDACCIO, P
    ROSSO, V
    STEFANINI, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 338 (2-3): : 549 - 555
  • [43] GaAs thin film epitaxy and X-ray detector development
    Wynne, D
    Cardozo, B
    Haller, EE
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS, 1999, 3768 : 196 - 203
  • [44] Experimental evaluation of a novel CdZnTe flat-panel X-ray detector for digital radiography and fluoroscopy
    Tokuda, S
    Adachi, S
    Sato, T
    Yoshimuta, T
    Nagata, H
    Uehara, K
    Izumi, Y
    Teranuma, O
    Yamada, S
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 140 - 147
  • [45] Dose efficiency and low-contrast detectability of an amorphous silicon x-ray detector for digital radiography
    Aufrichtig, R
    Xue, P
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (09): : 2653 - 2669
  • [46] Development of a novel direct X-ray detector using photoinduced discharge (PID) readout for digital radiography
    Heo, D.
    Jeon, S.
    Kim, J. -S.
    Kim, R. K.
    Cha, B. K.
    Moon, B. J.
    Yoon, J.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [47] X-ray Detector XRD on BeEagleSat and the Development of the Improved X-ray Detector iXRD
    Kalemci, Emrah
    Aslan, A. Rustem
    Bozkurt, Ayhan
    Bas, M. Erdem
    Diba, Milad
    Veziroglu, Kaan
    Aksulu, M. Deniz
    Uludag, M. Sevket
    Umit, M. Ertan
    2019 9TH INTERNATIONAL CONFERENCE ON RECENT ADVANCES IN SPACE TECHNOLOGIES (RAST), 2019, : 565 - 570
  • [48] Digital X-ray microscopy with a microfocal X-ray generation and an MWPC area detector
    Bateman, J.E.
    Moss, G.R.
    Rockett, P.
    Webb, S.
    Nuclear instruments and methods in physics research, 1988, 273 (2-3): : 767 - 772
  • [49] DIGITAL X-RAY MICROSCOPY WITH A MICROFOCAL X-RAY GENERATOR AND AN MWPC AREA DETECTOR
    BATEMAN, JE
    MOSS, GR
    ROCKETT, P
    WEBB, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 273 (2-3): : 767 - 772
  • [50] Tutorial on X-ray photon counting detector characterization
    Ren, Liqiang
    Zheng, Bin
    Liu, Hong
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2018, 26 (01) : 1 - 28