THE PB3300 INTRAARTERIAL BLOOD-GAS MONITORING-SYSTEM

被引:13
|
作者
LUMSDEN, T
MARSHALL, WR
DIVERS, GA
RICCITELLI, SD
机构
[1] FOxS Division, Puritan-Bennett Corporation, Carlsbad, 92009, CA
来源
JOURNAL OF CLINICAL MONITORING | 1994年 / 10卷 / 01期
关键词
MONITORING; OXYGEN; CARBON DIOXIDE; ACID-BASE EQUILIBRIUM; EQUIPMENT; SENSORS;
D O I
10.1007/BF01651467
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Continuous intraarterial blood gas (IABG) monitoring is in clinical use both in the operating room and intensive care unit. This technology uses miniature, optically-based sensors that can be placed into a patient's artery. The arterial blood gas values are transduced into an optical signal that is measured by a bedside monitor on which the values are displayed. In this paper, we describe the operating principles of the PB3300 Intra-Arterial Blood Gas Monitoring System (Puritan-Bennett Corporation, FOxS Division, Carlsbad, CA). Topics include the principles of fluorescent determinations of pH, PCO2, and PO2; the optical path of the PB3300; system calibration; dye layer geometry; and clinical operation. The accuracy, precision, and drift of the system measuring tonometered aqueous standards are reported. The following values were noted for eight sensors sending data to eight monitors: system bias and precisions of 0.00 +/- 0.02 pH at a pH of 7.40, -2.5 +/- 1.5 mm Hg PCO2 at a PCO2 of 40 mm Hg, and 3.3 +/- 1.3 mm Hg PO2 at a PO2 of 80 mm Hg.
引用
收藏
页码:59 / 66
页数:8
相关论文
共 50 条
  • [41] CONTINUOUS BLOOD-GAS MONITORING DURING LUNG TRANSPLANTATION
    GROH, J
    HALLER, M
    KILGER, E
    DIENEMANN, H
    REICHENSPURNER, H
    PETER, K
    ANESTHESIOLOGY, 1994, 81 (3A) : A617 - A617
  • [42] OXYGEN-THERAPY AND ARTERIAL BLOOD-GAS MONITORING
    SHARP, JT
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1982, 247 (09): : 1341 - 1341
  • [43] CONTINUOUS BLOOD-GAS MONITORING - A CHALLENGE MET AND ENGAGED
    YAFUSO, M
    HOLODY, M
    HANSMANN, D
    GEHRICH, J
    MAXWELL, T
    MILLER, W
    TUSA, J
    DEKTAR, J
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1990, 200 : 9 - IEC
  • [44] Continuous intra-arterial blood-gas monitoring
    Graystone, SJ
    BRITISH JOURNAL OF ANAESTHESIA, 1997, 79 (06) : 815 - 816
  • [45] CONTINUOUS BLOOD-GAS AND LACTATE MONITORING DURING EXERCISE
    SCHARDT, FW
    WIEGAND, MK
    FEDERATION PROCEEDINGS, 1986, 45 (13) : 2930 - 2932
  • [46] TCPO2 MONITORING REDUCES COSTS FOR BLOOD-GAS MONITORING
    LUCEY, JF
    DEHNER, LR
    PEDIATRIC RESEARCH, 1980, 14 (04) : 604 - 604
  • [47] COMPUTERIZED BLOOD-GAS INTERPRETATION AND REPORTING SYSTEM
    GARDNER, RM
    CANNON, GH
    MORRIS, AH
    OLSEN, KR
    PRICE, WG
    COMPUTER, 1975, 8 (01) : 39 - 45
  • [48] MONITORING-SYSTEM PROTECTS GAS-COMPRESSOR STATION
    不详
    I&CS-INDUSTRIAL AND PROCESS CONTROL MAGAZINE, 1983, 56 (07): : 46 - 46
  • [49] CLINICAL-EVALUATION CONTINUOUS REAL-TIME INTRAARTERIAL BLOOD-GAS MONITORING DURING ANESTHESIA AND SURGERY BY FIBER OPTIC SENSOR
    SMITH, BE
    KING, PH
    SCHLAIN, L
    INTERNATIONAL JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1992, 9 (01): : 45 - 52
  • [50] GAS-FLOW LIQUID SCINTILLATION MONITORING-SYSTEM
    HATAGAMI, T