Should automatic implantable cardioverter defibrillator (AICD) power sources be explanted and discontinued if they have not pulsed during the first generator life? We have followed 59 patients an average of 23 months (range, 3 days to 8.4 years) after AICD implantation. The indication for AICD implantation was based on clinical dysrhythmia, history of sudden death, and findings at electrophysiologic study. Thirty-eight of 59 patients (64%) had experienced sudden death and 52/58 (90%) were inducible at electrophysiologic study. Excluding 5 inappropriate pulsing episodes, 31 of 59 patients (53%) had 235 pulses (range, 1 to 36; median, 2 pulses). The time to first pulse after implantation ranged from 1 day to 3.5 years with a median time of 2 months. In 6 patients, the first pulsing occurred later than 1 year after AICD implantation. Fifteen generators demonstrating impending power source failure have been replaced in 11 patients. Power source depletion occurred at an average of 24.1 months (range, 8 to 40 months). In 3 patients, the first pulsing occurred after generator depletion and replacement. By univariate analysis, none of 13 variables (sex, age, cardiac disease process, functional class, previous myocardial infarction, sudden death history, ejection fraction, type of dysrhythmia, inducibility with electrophysiologic testing, number of extra stimuli required for induction, left ventricular aneurysm resection, endocardial resection, or concomitant operation) was found to be a predictor of pulsing (p > 0.05). We conclude that the majority of patients with pulses after AICD implantation will have them during the first 6 months. However, in this group of patients at high risk for sudden death by ventricular dysrhythmia, absence of pulsing during the first battery life does not justify explantation and discontinuance of AICD back-up.
引用
收藏
页码:984 / 987
页数:4
相关论文
共 50 条
  • [21] THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    MIROWSKI, M
    REID, PR
    MOWER, MM
    WATKINS, L
    PLATIA, EV
    GRIFFITH, LSC
    JUANTEGUY, JM
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1984, 7 (03): : 534 - 540
  • [22] EXPERIENCE WITH AN AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR
    HOLT, PM
    CRICK, JCP
    SOWTON, E
    LANCET, 1987, 1 (8532): : 551 - 553
  • [23] AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    LATTUCA, J
    VELTRI, EP
    AMERICAN HEART JOURNAL, 1989, 118 (06) : 1359 - 1359
  • [24] THE AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (AICD)
    DIXON, MW
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1988, 9 (02): : 172 - 173
  • [25] AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    EPSTEIN, AE
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1991, 102 (01): : 160 - 161
  • [26] LATE RESULTS OF THE LEFT SUBCOSTAL APPROACH FOR AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR IMPLANTATION
    ONEILL, PG
    LAWRIE, GM
    KAUSHIK, RR
    HARVILL, LF
    PACIFICO, A
    AMERICAN JOURNAL OF CARDIOLOGY, 1991, 67 (05): : 387 - 390
  • [27] IMPLANTATION OF COMBINED AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR AND PACEMAKER SYSTEMS - TECHNIQUES AND OUTCOME
    EPSTEIN, AE
    KAY, GN
    SHEPARD, RB
    KIRKLIN, JK
    PLUMB, VJ
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (04): : 486 - 486
  • [28] AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR - IS EARLY IMPLANTATION COST-EFFECTIVE
    ODONOGHUE, S
    PLATIA, EV
    BROOKSROBINSON, S
    MISPIRETA, L
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (05) : 1258 - 1263
  • [29] Cost reduction and implantable cardioverter defibrillator implantation
    McDonald, KM
    Hlatky, MA
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2001, 12 (02) : 167 - 168
  • [30] Implantable cardioverter defibrillator implantation in children in The Netherlands
    Ten Harkel, ADJ
    Blom, NA
    Reimer, AG
    Tukkie, R
    Sreeram, N
    Bink-Boelkens, MTE
    EUROPEAN JOURNAL OF PEDIATRICS, 2005, 164 (07) : 436 - 441