Pulse Wave Velocity Measured by Radial Artery Clip-type Pulsimeter Equipped with a Hall Device and Electrocardiogram

被引:4
|
作者
Lee, Kyu-Hwan [1 ]
Lee, Sang-Suk [1 ]
机构
[1] Sangji Univ, Coll Hlth & Sci, Dept Oriental Biomed Engn, Wonju 220702, Gangwon Do, South Korea
来源
关键词
magnetic sensing; Hall device; pulse wave velocity (PWV); electrocardiogram (ECG); radial artery pulse; clip-type pulsimeter;
D O I
10.4283/JKMS.2013.23.4.130
中图分类号
O59 [应用物理学];
学科分类号
摘要
The clip-type pulsimeter equipped with a magnetic sensing Hall device and the most popular body sign of the electrocardiogram (ECG) were investigated in order to analyze the pulse wave velocity (PWV). The PWV simultaneously calculated by means of time difference between the maximum peak of ECG pulse wave and the starting point of radial artery pulse wave, and distance difference between the heart position and the radial wrist position. The PWV analyzed from the clinical data was a wider scope of 5 similar to 7 m/s with an average value of 6 m/s. By the prediction of blood vessel's elasticity from the analysis of PWV, it may be useful for developing an oriental-western diagnostic medical signal device for a U-health-care system in the future.
引用
收藏
页码:130 / 134
页数:5
相关论文
共 50 条
  • [21] The pulse wave velocity and extensibility of the brachial and radial artery in man.
    Fulton, JS
    McSwiney, BA
    JOURNAL OF PHYSIOLOGY-LONDON, 1930, 69 (04): : 386 - 392
  • [22] Study of Pulse Wave Velocity Noninvasive Detecting Instrument Based on Radial Artery and Finger Photoplethysmography Pulse Wave
    Lin, Yang
    Song, Zhang
    Yang Yimin
    2008 INTERNATIONAL SYMPOSIUM ON INTELLIGENT INFORMATION TECHNOLOGY APPLICATION WORKSHOP: IITA 2008 WORKSHOPS, PROCEEDINGS, 2008, : 705 - 708
  • [23] Analysis of Blood Pressure Pulse Wave and Electrocardiogram Waveforms Measured by a Wearable Device with MEMS Sensors
    Osawa, Yosuke
    Hata, Satoshi
    Hori, Masataka
    Dohi, Tetsuji
    SENSORS AND MATERIALS, 2021, 33 (03) : 1063 - 1072
  • [24] BRACHIAL ANKLE GRADIENT PULSE WAVE VELOCITY (BAG-PWV) MEASURED WITH A NEW DEVICE CORRELATES WITH CAROTID FEMORAL PULSE WAVE VELOCITY
    Rico Martin, Sergio
    De Nicolas Jimenez, Jorge Manuel
    Claderon Garcia, Julian Fernando
    Sanchez Munoz-Torrero, Juan Francisco
    ATHEROSCLEROSIS, 2017, 263 : E152 - E152
  • [25] Determination of radial artery compliance can increase the diagnostic power of pulse wave velocity measurement
    Ferreira, AS
    Santos, MAR
    Barbosa, J
    Cordovil, I
    Souza, MN
    PHYSIOLOGICAL MEASUREMENT, 2004, 25 (01) : 37 - 50
  • [26] Pulse wave velocity of the leg minus that of the arm measured with a custom device correlates to the coronary calcium quantification
    Rico Martin, S.
    de Nicolas Jimenez, J. M.
    Moyano Calvente, S. L.
    Mogollon Jimenez, M. V.
    Vega Fernandez, J.
    Calderon Garcia, J. F.
    Bacaicoa Lopez de Sabando, M. A.
    Tardio, M.
    Sanchez Munoz-Torrero, J. F.
    REVISTA CLINICA ESPANOLA, 2016, 216 (04): : 191 - 197
  • [27] FINGER-TOE PULSE WAVE VELOCITY (FTPWV) MEASURED BY POPMETRE® DEVICE IN PATIENTS WITH ANKYLOSING SPONDYLITIS
    Alanis-Sanchez, G.
    Hallab, M.
    Boutouyrie, P.
    Laurent, S.
    Obeid, H.
    Khettab, H.
    Cardona-Mueller, D.
    Montes-Martinez, D.
    Murguia-Soto, C.
    Castaneda-Zaragoza, D.
    Cardona-Munoz, E.
    Ramos-Becerra, C.
    JOURNAL OF HYPERTENSION, 2018, 36 : E291 - E292
  • [28] INCREASED VASCULAR STIFFNESS MEASURED AS PULSE WAVE VELOCITY IS ASSOCIATED WITH THE PRESENCE AND SEVERITY OF CORONARY ARTERY DISEASE
    Ahmadi, Naser
    Nabavi, Vahid
    Oyang, Braynce L.
    Moshrefi, Shahin
    Pathak, Sagar J.
    Sourya-nejad, Sourya
    Isma'eel, Hussain
    Ebrahimi, Ramin
    Budoff, Matthew
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [29] Pulse wave velocity in patients with coronary artery disease or type 2 diabetes mellitus
    Cwynar, Marcin
    Gasowski, Jerzy
    Gryglewska, Barbara
    Dubiel, Marzena
    Grodzicki, Tomasz
    ACTA CARDIOLOGICA, 2006, 61 (04) : 421 - 426
  • [30] CALIBRATION MODE AFFECTS THE SIGNIFICANCE OF PULSE WAVE VELOCITY MEASURED BY A BRACHIAL CUFF-BASED MONITORING DEVICE FOR PREDICTION OF SIGNIFICANT CORONARY ARTERY DISEASE
    Shoji, T.
    Okada, S.
    Nakagomi, A.
    Kobayashi, Y.
    JOURNAL OF HYPERTENSION, 2015, 33 : E186 - E186