Pulse Wave Velocity Measured by Radial Artery Clip-type Pulsimeter Equipped with a Hall Device and Electrocardiogram

被引:4
|
作者
Lee, Kyu-Hwan [1 ]
Lee, Sang-Suk [1 ]
机构
[1] Sangji Univ, Coll Hlth & Sci, Dept Oriental Biomed Engn, Wonju 220702, Gangwon Do, South Korea
来源
关键词
magnetic sensing; Hall device; pulse wave velocity (PWV); electrocardiogram (ECG); radial artery pulse; clip-type pulsimeter;
D O I
10.4283/JKMS.2013.23.4.130
中图分类号
O59 [应用物理学];
学科分类号
摘要
The clip-type pulsimeter equipped with a magnetic sensing Hall device and the most popular body sign of the electrocardiogram (ECG) were investigated in order to analyze the pulse wave velocity (PWV). The PWV simultaneously calculated by means of time difference between the maximum peak of ECG pulse wave and the starting point of radial artery pulse wave, and distance difference between the heart position and the radial wrist position. The PWV analyzed from the clinical data was a wider scope of 5 similar to 7 m/s with an average value of 6 m/s. By the prediction of blood vessel's elasticity from the analysis of PWV, it may be useful for developing an oriental-western diagnostic medical signal device for a U-health-care system in the future.
引用
收藏
页码:130 / 134
页数:5
相关论文
共 50 条
  • [1] Analysis of Pulse Waveform and Pulse Wave Velocity of Carotid Artery and Radial Artery by Using Clip-type Pulsimeter Equipped with Permanent and Hall Device
    Kim, Dong-Young
    Lee, Sang-Suk
    Hyeon, Seog-San
    Rhee, Jin-Kyu
    JOURNAL OF THE KOREAN MAGNETICS SOCIETY, 2014, 24 (05): : 146 - 151
  • [2] Peripheral Blood Flow Velocity and Peripheral Pulse Wave Velocity Measured Using a Clip-type Pulsimeter Equipped with a Permanent Magnet and a Hall Device
    Kim, Keun-Ho
    Lee, Sang-Suk
    JOURNAL OF MAGNETICS, 2015, 20 (01) : 47 - 51
  • [3] Measurement of Spatial Pulse Wave Velocity by Using a Clip-Type Pulsimeter Equipped with a Hall Sensor and Photoplethysmography
    Nam, Dong-Hyun
    Lee, Woo-Beom
    Hong, You-Sik
    Lee, Sang-Suk
    SENSORS, 2013, 13 (04) : 4714 - 4723
  • [4] Analysis of Vacuous Pulse and Replete Pulse Using a Clip-type Pulsimeter Equipped with a Hall Sensor
    Lee, Nam-Kyu
    Rhee, Jin-Kyu
    Lee, Sang-Suk
    JOURNAL OF ACUPUNCTURE AND MERIDIAN STUDIES, 2015, 8 (02) : 83 - 93
  • [5] Analysis of Both Hands' Two Pulse Waveforms using a Clip-type Pulsimeter Equipped with Magnetic Sensing Hall Device
    Rhee, Jin-Kyu
    Lee, Sang-Suk
    JOURNAL OF MAGNETICS, 2013, 18 (02) : 183 - 187
  • [6] Measurement and Analysis of Pulse Wave using Clip Type Pulsimeter Equipped with a Permanent Magnet and a Hall Device
    Son, Il-Ho
    Lee, Sang-Suk
    JOURNAL OF THE KOREAN MAGNETICS SOCIETY, 2011, 21 (03): : 104 - 107
  • [7] Extraction of Respiratory Rate by using FFT for Radial Artery Pulse Waves Acquisited by Clip-type Pulsimeter with a Hall Sensor
    Cho, Hyun-Sung
    Lee, Sang-Suk
    JOURNAL OF THE KOREAN MAGNETICS SOCIETY, 2012, 22 (05): : 178 - 182
  • [8] Property of Wireless Clip-type Pulsimeter by Using a Hall Device and a Permanent Magnet
    Yoon, Woo-Sung
    Ji, Jong-Ok
    Lee, Sang-Suk
    JOURNAL OF THE KOREAN MAGNETICS SOCIETY, 2014, 24 (06): : 179 - 185
  • [9] The Characteristics of Peripheral Blood Flow Velocity Measured by a Semiconductor Hall Device Clip-Type Pulsimeter and PPG for the Effect of Shoulder Thermal Treatment
    Lee, Seung-Yun
    Han, Hye-Ji
    Lee, Sang-Suk
    JOURNAL OF THE KOREAN MAGNETICS SOCIETY, 2021, 31 (05): : 236 - 241
  • [10] Development of Prediction Algorithm for Replete Pulse and Vacuous Pulse by using Clip-type Pulsimeter with Hall Device Measuring a Magnetic Field
    Lee, Nam-Kyu
    Kim, Keun-Ho
    Lee, Sang-Suk
    Yu, Ji-Hye
    Yu, Jun-Sang
    Sun, Seung-Ho
    Chang, Sei Jin
    Hong, Yu-Sik
    JOURNAL OF THE KOREAN MAGNETICS SOCIETY, 2013, 23 (03): : 104 - 109