LONG-TERM TESTS OF LIMITED STREAMER TUBES

被引:1
|
作者
LAU, K [1 ]
PARKS, D [1 ]
PYRLIK, J [1 ]
WEINSTEIN, R [1 ]
机构
[1] UNIV HOUSTON,DEPT PHYS,HOUSTON,TX 77204
关键词
D O I
10.1016/0168-9002(92)90782-Y
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We studied the long-term behavior of 160 6-meter eight-cell Iarocci type streamer chambers under typical operating conditions for 400 days. Two chambers failed during this test, corresponding to an average failure rate of 1.3 +/- 0.8% per year. We also observed large systematic variations of chamber current as a function of the isobutane purity.
引用
收藏
页码:243 / 248
页数:6
相关论文
共 50 条
  • [21] THE LIMITED STREAMER TUBES FOR EXPERIMENT PS199 AT LEAR
    BIRSA, R
    CILIBERTI, P
    TORRECOLAUTTI, SD
    LAMANNA, M
    MARTIN, A
    MENON, G
    TESSAROTTO, F
    MASONI, A
    PUDDU, G
    AGNELLO, M
    IAZZI, F
    DEMARCO, N
    MUSSO, A
    PICCOTTI, A
    SIMONETTI, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 300 (01): : 43 - 52
  • [22] LARGE-SERIES TEST OF LIMITED STREAMER TUBES.
    Caria, M.
    Ereditato, A.
    Flegel, W.
    Gatto, C.
    Gorini, E.
    Grancagnolo, F.
    Iasevoli, R.
    King, A.
    Palladino, V.
    Seiden, A.
    Strolin, P.
    Nuclear instruments and methods in physics research, 1987, A260 (2-3): : 368 - 372
  • [23] A barrel IFR instrumented with limited streamer tubes for babar experiment
    Cibinetto, G
    INTERNATIONAL JOURNAL OF MODERN PHYSICS A, 2005, 20 (16): : 3834 - 3838
  • [24] A METHOD FOR TESTING TUBES FOR LONG-TERM STRENGTH
    ASVIYAN, MB
    AZIZOV, IA
    INDUSTRIAL LABORATORY, 1966, 32 (09): : 1380 - &
  • [25] LONG-TERM PLACEMENT OF SILASTIC NASOLACRIMAL TUBES
    VELOUDIOS, A
    HARVEY, JT
    PHILIPPON, M
    OPHTHALMIC SURGERY AND LASERS, 1991, 22 (04): : 225 - 227
  • [26] EVENT RECORDER FOR LONG-TERM TESTS
    MYRONUK, RS
    FOREST PRODUCTS JOURNAL, 1980, 30 (08) : 28 - 29
  • [27] Long-term ventilation tubes: for how long should they be used?
    Mohammed, H.
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2013, 127 (09): : 948 - 949
  • [28] Flexural creep tests and long-term mechanical behavior of fiber-reinforced polymeric composite tubes
    Yang, Zengqin
    Wang, Hui
    Ma, Xiaofei
    Shang, Fulin
    Ma, Yu
    Shao, Zhenwei
    Hou, Demen
    COMPOSITE STRUCTURES, 2018, 193 : 154 - 164
  • [29] THE TEST SYSTEM OF THE DIGITAL ELECTRONICS FOR THE CHARM II LIMITED STREAMER TUBES
    CARIA, M
    EREDITATO, A
    GATTO, C
    GRANCAGNOLO, F
    PALLADINO, V
    PARASCANDOLO, P
    STROLIN, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 241 (01): : 100 - 106
  • [30] SPATIAL-RESOLUTION OF LIMITED STREAMER TUBES WITH ANALOG STRIP READOUT
    DAGOSTINI, G
    DEBOER, W
    FRENKEL, A
    IACOVACCI, M
    MARINI, G
    STELLA, B
    CATANESI, G
    RUGGERI, F
    CROSETTI, G
    RAMELLO, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 252 (2-3): : 431 - 434