Plan quality and delivery time comparisons between volumetric modulated arc therapy and intensity modulated radiation therapy for scalp angiosarcoma: A planning study

被引:16
|
作者
Kai, Yudai [1 ]
Toya, Ryo [2 ,3 ]
Saito, Tetsuo [2 ]
Kuraoka, Akiko [1 ]
Shimohigashi, Yoshinobu [1 ]
Nakaguchi, Yuji [1 ]
Maruyama, Masato [1 ]
Murakami, Ryuji [4 ]
Yamashita, Yasuyuki [5 ]
Oya, Natsuo [2 ]
机构
[1] Kumamoto Univ Hosp, Dept Radiol Technol, Kumamoto, Japan
[2] Kumamoto Univ Hosp, Dept Radiat Oncol, Kumamoto, Japan
[3] Univ Wisconsin, Dept Human Oncol, Sch Med & Publ Hlth, Madison, WI USA
[4] Kumamoto Univ, Dept Med Imaging, Fac Life Sci, Kumamoto, Japan
[5] Kumamoto Univ Hosp, Dept Diagnost Radiol, Kumamoto, Japan
来源
JOURNAL OF MEDICAL RADIATION SCIENCES | 2018年 / 65卷 / 01期
关键词
Angiosarcoma; intensity modulated radiation therapy; scalp irradiation; volumetric modulated arc therapy; X-ray Voxel Monte Carlo algorithm;
D O I
10.1002/jmrs.239
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: Due to its spherical surface, scalp angiosarcoma requires careful consideration for radiation therapy planning and dose delivery. Herein, we investigated whether volumetric modulated arc therapy (VMAT) is superior to intensity modulated radiation therapy (IMRT) in terms of the plan quality and delivery time. Methods: Three different coplanar treatment plans were created for four patients, comprising a two-arc VMAT plan as well as 5-field and 9-field IMRT plans with 6 MV beams. The X-ray Voxel Monte Carlo algorithm was employed for dose calculation. A radiation therapy dose of 60 Gy was prescribed to the planning target volume (PTV) in 30 fractions. The homogeneity indexes (HIs) and conformity indexes (CIs) of the PTV, organs at risk (OARs) doses and delivery times were calculated and compared. Results: For the VMAT, 5-field and 9-field IMRT plans, the mean HIs were 0.14, 0.16 and 0.15; CIs(100%) were 0.63, 0.61 and 0.64; CIs(98%) were 0.72, 0.66 and 0.70 and CIs(95%) were 0.74, 0.67 and 0.71 respectively. All mean dose parameters of the VMAT and 9-field IMRT plans for the brain were equal to or lower than those of the 5-field IMRT plan. For the 5-field IMRT plan, the dose constraints for the left lens were not satisfied in two patients. The mean delivery times were 3.3, 11.1 and 14.7 min for the VMAT, 5-field and 9-field IMRT plans respectively. Conclusion: The VMAT plan quality is comparable to that of 9-field IMRT, with a reduced delivery time. Therefore, VMAT represents a valuable, sophisticated irradiation technique for treating scalp angiosarcoma.
引用
收藏
页码:39 / 47
页数:9
相关论文
共 50 条
  • [21] Comparison of Intensity-Modulated Radiation Therapy, Intensity-Modulated Arc Therapy and Arc-Modulated Radiation Therapy
    Tang, G.
    Earl, M.
    Luan, S.
    Wang, C.
    Naqvi, S.
    Yu, C.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [22] Dosimetric Evaluation of Noncoplanar Intensity Modulated Radiation Therapy and Volumetric Modulated Arc Therapy Delivery Techniques for Cervical Stereotactic Body Radiation Therapy Treatments
    Cohen, D.
    Delgado, A. Brito
    Eng, T. Y.
    Gutierrez, A. N.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E666 - E667
  • [23] Volumetric modulated arc therapy versus conventional intensity modulated radiation therapy for stereotactic spine radiotherapy: A planning study and early clinical data
    Kuijper, Ingrid T.
    Dahele, Max
    Senan, Suresh
    Verbakel, Wilko F. A. R.
    RADIOTHERAPY AND ONCOLOGY, 2010, 94 (02) : 224 - 228
  • [24] A Planning Study to Compare Plans using Volumetric Modulated Arc Therapy or Intensity-modulated Radiation Therapy for the Treatment of Anal Canal Cancer
    Dubois, J.
    Vieillot, S.
    Moscardo, C. Llacer
    Lemanski, C.
    Azria, D.
    Fenoglietto, P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S729 - S730
  • [25] Cardiac Toxicity in Intensity Modulated Radiation Therapy, Dynamic Conformal Arc Therapy, and Volumetric Modulated Arc Therapy of Lung Cancers
    Ming, X.
    Feng, Y.
    Zhang, Y.
    Zhou, L.
    Deng, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S666 - S667
  • [26] Time Optimal Delivery of Intensity Modulated Arc Therapy
    Rangaraj, D.
    Yang, D.
    Goddu, S.
    Papiez, L.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [27] Modulation indices and plan delivery accuracy of volumetric modulated arc therapy
    Park, Jong Min
    Kim, Jung-in
    Park, So-Yeon
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (06): : 12 - 22
  • [28] Planning and delivery of intensity-modulated radiation therapy
    Yu, Cedric X.
    Amies, Christopher J.
    Svatos, Michelle
    MEDICAL PHYSICS, 2008, 35 (12) : 5233 - 5241
  • [29] Volumetric Modulated Arc Therapy for Brain Tumors: Dosimetric Comparison with Intensity-Modulated Radiation Therapy
    Ter-Antonyan, R.
    Yang, W.
    Geesey, C.
    Lain, D.
    Larner, J.
    Benedict, S.
    MEDICAL PHYSICS, 2010, 37 (06) : 3213 - +
  • [30] Dosimetric comparison of volumetric modulated arc therapy and intensity-modulated radiation therapy for pancreatic malignancies
    Ali, Arif N.
    Dhabaan, Anees H.
    Jarrio, Christie S.
    Siddiqi, Arsalan K.
    Landry, Jerome C.
    MEDICAL DOSIMETRY, 2012, 37 (03) : 271 - 275