SAMPLE TIP COUPLING EFFICIENCIES OF THE PHOTON-SCANNING TUNNELING MICROSCOPE

被引:45
|
作者
SALOMON, L
DEFORNEL, F
GOUDONNET, JP
机构
[1] Laboratoire Physique du Solide Section, Photoêlectricité, Université de Bourgogne, Dijon, 21004
关键词
D O I
10.1364/JOSAA.8.002009
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The photon-scanning tunneling microscope is the photon analog to the electron-scanning tunneling microscope. It uses the evanescent field due to the total internal reflection of a light beam in a prism, modulated by a sample attached to the prism. The exponential decay of the evanescent field is characterized by the penetration depth d(p) and depends on the angle of incidence theta, the wavelength, and the polarization of the incident beam. The 1/e decay lengths range from 150 to 265 nm as deduced from the expression of the electric-field intensity in the rarer medium for theta = pi/2. If we place another optically transparent medium near the surface, frustrated total reflection occurs. It is shown theoretically and experimentally that, if we choose an appropriate angle of incidence theta(theta not-equal pi/2) and change the index of refraction of one of the media, the decay length of the electric field can be extremely small, so that images with an improved resolution can be produced.
引用
收藏
页码:2009 / 2015
页数:7
相关论文
共 50 条
  • [31] Photon emission induced by the scanning tunneling microscope
    Berndt, R
    Bohringer, M
    LASER TECHNIQUES FOR SURFACE SCIENCE III, 1998, 3272 : 66 - 72
  • [32] PHOTON-EMISSION SCANNING TUNNELING MICROSCOPE
    BERNDT, R
    SCHLITTLER, RR
    GIMZEWSKI, JK
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1991, 9 (02): : 573 - 577
  • [34] REPRODUCIBLE FABRICATION TECHNIQUE OF NANOMETRIC TIP DIAMETER FIBER PROBE FOR PHOTON SCANNING TUNNELING MICROSCOPE
    PANGARIBUAN, T
    YAMADA, K
    JIANG, SD
    OHSAWA, H
    OHTSU, M
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 1992, 31 (9A): : L1302 - L1304
  • [35] Reproducible fabrication technique of nanometric tip diameter fiber probe for photon scanning tunneling microscope
    Pangaribuan, Togar
    Yamada, Kazunobu
    Jiang, Shudong
    Ohsawa, Hisao
    Ohtsu, Motoichi
    Japanese Journal of Applied Physics, Part 2: Letters, 1992, 31 (9 A):
  • [36] HEATED SAMPLE HOLDER FOR A SCANNING TUNNELING MICROSCOPE
    EDELMAN, VS
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1994, 37 (04) : 528 - 530
  • [37] Electromagnetic properties of scanning tunneling microscope tip-sample gap in the terahertz frequency range
    Uehara, Yoichi
    Katano, Satoshi
    Kuwahara, Masashi
    Suzuki, Tetsu
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2015, 54 (08)
  • [38] Electromagnetic properties of scanning tunneling microscope tip-sample gap in the terahertz frequency range
    Uehara, Yoichi
    Katano, Satoshi
    Kuwahara, Masashi
    Suzuki, Tetsu
    Japanese Journal of Applied Physics, 2015, 54 (08):
  • [39] SPHERICAL TIP MODEL IN THE THEORY OF THE SCANNING TUNNELING MICROSCOPE
    CHUNG, MS
    FEUCHTWANG, TE
    CUTLER, PH
    SURFACE SCIENCE, 1987, 181 (1-2) : 412 - 412
  • [40] GOLD DEPOSITION FROM A SCANNING TUNNELING MICROSCOPE TIP
    MAMIN, HJ
    CHIANG, S
    BIRK, H
    GUETHNER, PH
    RUGAR, D
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1991, 9 (02): : 1398 - 1402