Effect of Channel Orientation and Rib Pitch-to-Height Ratio on Pressure Drop in a Rotating Square Channel with Ribs on Two Opposite Surfaces

被引:5
|
作者
Prabhu, S. V. [1 ]
Arora, Neelabh [1 ]
Vedula, R. P. [1 ]
机构
[1] Indian Inst Technol, Dept Mech Engn, Bombay 400076, Maharashtra, India
关键词
rotation; ribs; turbine blade cooling; orientation; pressure drop;
D O I
10.1155/IJRM.2005.67
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The effect of channel orientation and rib pitch-to-height ratio on the pressure drop distribution in a rib-roughened channel is an important issue in turbine blade cooling. The present investigation is a study of the overall pressure drop distribution in a square cross-sectioned channel, with rib turbulators, rotating about an axis normal to the free stream. The ribs are configured in a symmetric arrangement on two opposite surfaces with a rib angle of 90. to the mainstream flow. The study has been conducted for three Reynolds numbers, namely, 13 000, 17 000, and 22 000 with the rotation number varying from 0-0.38. Experiments have been carried out for various rib pitch-to-height ratios (P/e) with a constant rib height-to-hydraulic diameter ratio (e/D) of 0.1. The test section in which the ribs are placed on the leading and trailing surfaces is considered as the base case (orientation angle = 0 degrees, Coriolis force vector normal to the ribbed surfaces). The channel is turned about its axis in steps of 15. to vary the orientation angle from 0 degrees to 90 degrees The overall pressure drop does not change considerably under conditions of rotation for the base case. However, for the other cases tested, it is observed that the overall pressure drop increases with an increase in the rotation number for a given orientation angle and also increases with an increase in the orientation angle for a given rotation number. This change is attributed to the variation in the separation zone downstream of the ribs due to the presence of the Coriolis force-local pressure drop data is presented which supports this idea. At an orientation angle of 90 degrees (ribs on the top and bottom surfaces, Coriolis force vector normal to the smooth surfaces), the overall pressure drop is observed to be maximum during rotation. The overall pressure drop for a case with a rib pitch-to-height ratio of 5 on both surfaces is found to be the highest among all the rib pitch-to-height ratios covered in this study with the maximum increase in the overall pressure drop being as high as five times the corresponding no-rotation case at the highest rotation number of 0.38 and 90 degrees orientation angle.
引用
收藏
页码:67 / 76
页数:10
相关论文
共 50 条
  • [21] On flow structure, heat transfer and pressure drop in varying aspect ratio two-pass rectangular channel with ribs at 45°
    Siddique, Waseem
    Shevchuk, Igor V.
    El-Gabry, Lamyaa
    Hushmandi, Narmin B.
    Fransson, Torsten H.
    HEAT AND MASS TRANSFER, 2013, 49 (05) : 679 - 694
  • [22] Numerical Simulation of the Effect of Channel Orientation on Fluid Flow and Heat Transfer at High Buoyancy Number in a Rotating Two-Pass Channel With Angled Ribs
    Brahim, Berrabah
    Miloud, Aminallah
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2019, 141 (02):
  • [23] On flow structure, heat transfer and pressure drop in varying aspect ratio two-pass rectangular channel with ribs at 45°
    Waseem Siddique
    Igor V. Shevchuk
    Lamyaa El-Gabry
    Narmin B. Hushmandi
    Torsten H. Fransson
    Heat and Mass Transfer, 2013, 49 : 679 - 694
  • [24] NUMERICAL SIMULATIONS OF FLOW STRUCTURE AND TURBULENT HEAT TRANSFER IN A SQUARE RIBBED CHANNEL WITH VARYING RIB PITCH RATIO
    Khalid, Aayan
    Xie, Gongnan
    Sunden, Bengt
    JOURNAL OF ENHANCED HEAT TRANSFER, 2016, 23 (02) : 155 - 174
  • [25] Effect of rib spacing on heat transfer and friction in a rotating two-pass square channel with asymmetrical 90-deg rib turbulators
    Xu, Guoqiang
    Li, Yang
    Deng, Hongwu
    APPLIED THERMAL ENGINEERING, 2015, 80 : 386 - 395
  • [26] EXPERIMENTAL INVESTIGATION OF ROTATING RIB ROUGHENED TWO-PASS SQUARE DUCT WITH TWO DIFFERENT CHANNEL ORIENTATIONS
    Singh, Prashant
    Ekkad, Srinath V.
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2017, VOL 5A, 2017,
  • [27] Influence of channel height on heat transfer augmentation in rectangular channels with two opposite rib-roughened walls
    Chang, SW
    Liou, TM
    Juan, WC
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2005, 48 (13) : 2806 - 2813
  • [28] Rib spacing effect on heat transfer and pressure loss in a rotating two-pass rectangular channel (AR=1:2) with 45-degree angled ribs
    Liu, Yao-Hsien
    Wright, Lesley M.
    Fu, Wen-Lung
    Han, Je-Chin
    PROCEEDINGS OF THE ASME TURBO EXPO 2006, VOL 3, PTS A AND B: HEAT TRANSFER: GENERAL INTEREST, 2006, : 363 - 373
  • [29] Effect of Number of Rough Walls on Pressure Drop and Heat Transfer in Square Channel
    Bae, Sung Taek
    Kim, Myoung Ho
    Ahn, Soo Whan
    Jin, Yong Soo
    Kim, Sung Tae
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2005, 29 (03) : 340 - 348
  • [30] HEAT TRANSFER AND PRESSURE DROP CHARACTERISTICS FOR FLOW THROUGH SQUARE CHANNEL WITH DELTA WING VORTEX GENERATOR ELEMENTS ON TWO OPPOSITE WALLS
    Nalawade, M. K.
    Bhati, A.
    Vedula, R. P.
    JOURNAL OF ENHANCED HEAT TRANSFER, 2019, 26 (02) : 101 - 126