CT-GUIDED BONE-BIOPSY PERFORMED BY MEANS OF A COAXIAL BIOPSY SYSTEM WITH AN ECCENTRIC DRILL

被引:29
|
作者
AHLSTROM, KH
ASTROM, KGO
机构
[1] Department of Diagnostic Radiology, Akademiska Sjukhuset, University Hospital
关键词
BONE MARROW; BIOPSY; BONE NEOPLASMS; DIAGNOSIS; BONES; INTERVENTIONAL PROCEDURES; TECHNOLOGY;
D O I
10.1148/radiology.188.2.8327713
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Thirty-seven consecutive bone biopsies guided with computed tomography were performed in 32 patients by use of three different techniques to penetrate cortical bone and gain access to the lesion. The following instruments were used: a thin bone biopsy needle (12 biopsies), a conventional drill with an outer cannula (six biopsies), and a coaxial biopsy system that consists of a drill with an eccentric tip and an outer cannula (19 biopsies). This eccentric drill makes a hole in the bone larger than the diameter of the cannula and thereby makes it easy to advance the cannula over the drill until the cannula is anchored in the bone. One can then obtain multiple samples through the cannula. The thin bone biopsy needle could not penetrate thick (8 mm thick) cortical bone. The outer cannula was not anchored in the bone when the conventional drill was used. In 16 biopsies, the new coaxial biopsy system penetrated cortical bone with a thickness of 1-8 mm and was anchored there, and lesion samples were obtained through the anchored cannula.
引用
收藏
页码:549 / 552
页数:4
相关论文
共 50 条
  • [31] CT-guided needle biopsy
    Siddiqui, MA
    HOSPITAL PRACTICE, 1995, 30 (11): : 28 - 28
  • [32] CT-guided Coaxial Lung Biopsy: Number of Cores and Association with Complications
    Kim, Charissa R.
    Sari, Mehmet Ali
    Grimaldi, Elena
    VanderLaan, Paul A.
    Brook, Alexander
    Brook, Olga R.
    RADIOLOGY, 2024, 313 (02)
  • [33] CT-GUIDED CORE BIOPSY OF DIFFICULT LESIONS - A MODIFIED COAXIAL APPROACH
    SWERDLOW, DR
    THAETE, FL
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (01) : 195 - 196
  • [34] Fluoroscopy-guided intervertebral disc biopsy with a coaxial drill system
    Wallace, Adam N.
    Pacheco, Rafael A.
    Vyhmeister, Ross
    Tomasian, Anderanik
    Chang, Randy O.
    Jennings, Jack W.
    SKELETAL RADIOLOGY, 2016, 45 (02) : 273 - 278
  • [35] Fluoroscopy-guided intervertebral disc biopsy with a coaxial drill system
    Adam N. Wallace
    Rafael A. Pacheco
    Ross Vyhmeister
    Anderanik Tomasian
    Randy O. Chang
    Jack W. Jennings
    Skeletal Radiology, 2016, 45 : 273 - 278
  • [36] CT-guided bone biopsy:: Initial experience with a commercially available hand held Black and Decker™ drill
    Buckley, O.
    Benfayed, W.
    Geoghegan, T.
    Al-Ismail, K.
    Munk, P. L.
    Torreggiani, William C.
    EUROPEAN JOURNAL OF RADIOLOGY, 2007, 61 (01) : 176 - 180
  • [37] A Path Planning System for CT-guided Lung Biopsy
    Feng R.
    Tang L.
    Emu Y.
    Zhang X.
    Zhang J.
    Zhong J.
    He L.
    Jiqiren/Robot, 2022, 44 (06): : 694 - 707
  • [38] LASER PROJECTION SYSTEM FOR RADIOTHERAPY AND CT-GUIDED BIOPSY
    NAGATA, Y
    NISHIDAI, T
    ABE, M
    HIRAOKA, M
    TAKAHASHI, M
    FUJIWARA, K
    OKAJIMA, K
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (06) : 1046 - 1048
  • [39] CT-guided Bone Biopsy in Childhood: often ambiguous Results
    Lorenz, Judith
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2019, 191 (01): : 16 - 16
  • [40] AN IMPROVED TRANSILIAL CREST BONE-BIOPSY DRILL FOR QUANTITATIVE HISTOMORPHOMETRY
    LALOR, B
    FREEMONT, A
    CARLILE, S
    BONE, 1986, 7 (04) : 273 - 276