BREAST THICKNESS IN ROUTINE MAMMOGRAMS - EFFECT ON IMAGE QUALITY AND RADIATION-DOSE

被引:66
|
作者
HELVIE, MA
CHAN, HP
ADLER, DD
BOYD, PG
机构
[1] Department of Radiology, Taubman Center, University of Michigan Medical Ctr., Ann Arbor, MI 48109-0326
关键词
D O I
10.2214/ajr.163.6.7992731
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to compare the thickness of the compressed breast between mediolateral oblique and craniocaudal mammograms and to relate these differences in thickness to image quality and radiation dose. These differences may partially explain why some subtle tumors are better visualized on the cranio caudal view. SUBJECTS AND METHODS. The study population consisted of 250 paired mediolateral oblique and craniocaudal mammograms obtained on one mammographic unit by seven certified mammography technologists during a P-month period. Only women with breast implants,prior lumpectomy and radiotherapy, or chest wall deformity were excluded. The digital readout of compressed breast thickness and applied compression force was recorded. Mammographic positioning was assessed using standard criteria. Absorbed radiation dose at different thicknesses was measured with a BR-12 breast phantom. Image quality differences for geometric unsharpness and contrast were calculated for the observed breast thickness differences between mediolateral oblique and craniocaudal mammograms. RESULTS. The mean thickness of the compressed breast on the craniocaudal view was less than the mean thickness on the mediolateral oblique view (4.4 versus 4.8 cm, p < .0001) despite the greater force used to compress the breast for mediolateral oblique than for craniocaudal views (93 versus 86 newtons, p < .0001). The breast thickness on the mediolateral oblique view exceeded that on the craniocaudal view in 98 (84%) of 117 pairs that differed in thickness by 5 mm or more and 46 (94%) of 49 pairs that differed by 10 mm or more (p < .0001). Geometric unsharpness increased by 8% and 19% when a 4.4-cm-thick breast was compared to a 4.8- and 5.4-cm-thick breast, respectively. A 5% and 12% loss of contrast was noted when a 4.4-cm-thick breast was compared to a 4.8- and 5.4-cm-thick breast, Mean glandular radiation dose at 4.4, 4.8, and 5.4 cm was 1.40, 1.70, and 2.33 mGy, respectively. CONCLUSION, The compressed breast is 8% thicker on mediolateral oblique than on craniocaudal mammograms, a small but statistically significant difference. This difference results in a small loss of spatial and contrast resolution on the mediolateral oblique views and an increase in radiation dose. These image quality differences may partially explain why some subtle carcinomas are better visualized on the craniocaudal view.
引用
收藏
页码:1371 / 1374
页数:4
相关论文
共 50 条
  • [31] Multidetector CT of bronchiectasis: Effect of radiation dose on image quality
    Yi, CA
    Lee, KS
    Kim, TS
    Han, DH
    Sung, YM
    Kim, S
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (02) : 501 - 505
  • [32] RADIATION-DOSE, DOSE-RATE, AND QUALITY IN SUPPRESSION OF HUMORAL IMMUNE-RESPONSE
    GOTTLIEB, CF
    GENGOZIAN, N
    JOURNAL OF IMMUNOLOGY, 1972, 109 (04): : 719 - +
  • [33] THE EFFECT OF CARBIMAZOLE FOLLOWING RADIOIODINE THERAPY ON RADIATION-DOSE TO THE THYROID
    GIMLETTE, TMD
    KOCAK, R
    HERBERT, RG
    SQUIRE, CR
    NUKLEARMEDIZIN, 1981, 20 (02) : 72 - 75
  • [34] UNEXPECTED EFFECT OF FRACTIONATION OF RADIATION-DOSE ON INDUCTION OF NONDISJUNCTION IN DROSOPHILA
    SOBELS, FH
    GENETICS, 1973, 74 (JUN) : S260 - S260
  • [35] STUDY OF THE EFFECT OF RADIATION-DOSE ON THE KINETICS OF ANNEALING OF BARIUM NITRATE
    DUTTA, A
    PRADHAN, D
    PRADHAN, GB
    PATRA, P
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 1993, 70 (03) : 244 - 246
  • [36] Editorial: Radiation dose and image quality
    Manning, David
    RADIOGRAPHY, 2014, 20 (04) : 291 - 292
  • [37] CT radiation dose and image quality
    Payne, JT
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2005, 43 (06) : 953 - +
  • [38] Cone-Beam CT for Breast Imaging: Radiation Dose, Breast Coverage, and Image Quality
    O'Connell, Avice
    Conover, David L.
    Zhang, Yan
    Seifert, Posy
    Logan-Young, Wende
    Lin, Chuen-Fu Linda
    Sahler, Lawrence
    Ning, Ruola
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (02) : 496 - 509
  • [39] Mammography radiation dose and image quality
    Jacobson, DR
    RADIATION PROTECTION DOSIMETRY, 1998, 80 (1-3) : 295 - 297
  • [40] Tradeoffs in image quality and radiation dose
    McNitt-Gray, M
    MEDICAL PHYSICS, 2004, 31 (06) : 1802 - 1802