IN-VITRO EFFECTS OF LOW-CALCIUM PERITONEAL-DIALYSIS SOLUTIONS ON PERITONEAL MACROPHAGE FUNCTIONS

被引:2
|
作者
KIEFER, T
SCHENK, U
HUBEL, E
WEBER, J
METTANG, T
PASSLICKDEETJEN, J
KUHLMANN, U
机构
[1] ROBERT BOSCH KRANKENHAUS,DEPT INTERNAL MED,DIV NEPHROL,D-70376 STUTTGART,GERMANY
[2] FRESENIUS AG,OBERURSEL,GERMANY
关键词
PERITONEAL DIALYSIS; CONTINUOUS AMBULATORY PERITONEAL DIALYSIS; PERITONEAL MACROPHAGE; LOW CALCIUM; PERITONEAL DIALYSIS SOLUTION; LEUKOCYTE FUNCTION;
D O I
10.1016/0272-6386(95)90551-0
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
The use of low-calcium peritoneal dialysis solutions (PDS) for continuous ambulatory peritoneal dialysis is becoming widely accepted to reduce the risk of serum hypercalcemia in patients taking calcium salts as phosphate binders. We compared the in vitro effects of low-calcium PDS (1,000 mu mol calcium/L), calcium-free buffer, and buffers with increasing calcium concentrations (500 to 5,000 mu mol calcium/L) on peritoneal macrophage (PMO) functions. Peritoneal macrophages isolated from 10 continuous ambulatory peritoneal dialysis patients were incubated in the different solutions and tested for phagocytic and killing capacity, superoxide generation (cytochrome-C reduction and lucigenin-enhanced chemiluminescence), and the rate of myeloperoxidase-dependent oxidative metabolism (luminol-enhanced chemiluminescence). All functions of the PMO incubated in calcium-free buffer were significantly suppressed compared with the PMO incubated in calcium buffers. No dose-dependent increase of a single PMO function could be found after incubating the PMO in calcium buffer with increasing concentrations, Incubation of PMO in otherwise identical PDS containing 1,000, 1,450, or 1,750 mu mol calcium/L did not result in significantly different PMO functions. Acidic PDS (pH 5.3 to 5.5) suppressed all measured PMO functions as compared with their neutralized counterparts (pH 7.4), irrespective of the calcium concentration. Results of our in vitro study show that low-calcium PDS does not suppress PMO functions any more than standard-calcium PDS (1,750 mu mol calcium/L) does. (C) 1995 by the National Kidney Foundation, Inc.
引用
收藏
页码:751 / 760
页数:10
相关论文
共 50 条
  • [21] OSMOTIC AGENTS FOR PERITONEAL-DIALYSIS SOLUTIONS
    WU, G
    PERITONEAL DIALYSIS BULLETIN, 1982, 2 (04): : 151 - 154
  • [22] RECOMMENDATIONS ON CHOICE OF PERITONEAL-DIALYSIS SOLUTIONS
    VIDT, DG
    ANNALS OF INTERNAL MEDICINE, 1973, 78 (01) : 144 - 146
  • [23] IN-VITRO STUDIES ON THE EFFECT OF DIALYSIS SOLUTIONS ON PERITONEAL LEUKOCYTES
    JORRES, A
    GAHL, GM
    FREI, U
    PERITONEAL DIALYSIS INTERNATIONAL, 1995, 15 (07): : S41 - S46
  • [24] BICARBONATE SOLUTIONS FOR PERITONEAL-DIALYSIS - A REALITY
    FERIANI, M
    BIASIOLI, S
    BORIN, D
    BRENDOLAN, A
    GARGANTINI, L
    CHIARAMONTE, S
    FABRIS, A
    RONCO, C
    LAGRECA, G
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1985, 8 (01): : 57 - 58
  • [25] IMPROVED SOLUTIONS FOR PERITONEAL-DIALYSIS - PHYSIOLOGICAL CALCIUM SOLUTIONS, OSMOTIC AGENTS AND BUFFERS
    HUTCHISON, AJ
    GOKAL, R
    KIDNEY INTERNATIONAL, 1992, 42 : S153 - S159
  • [26] IN-VITRO SIMULATION OF THE EFFECT OF PERITONEAL-DIALYSIS FLUID ON MESOTHELIAL CELLS (MC)
    BREBOROWICZ, A
    RODELA, H
    MARTIS, L
    OREOPOULOS, DG
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1995, 6 (03): : 593 - 593
  • [27] Low or high calcium dialysate solutions in peritoneal dialysis?
    Weinreich, T
    KIDNEY INTERNATIONAL, 1996, 50 : S92 - S96
  • [28] ARE ALDEHYDES IN HEAT-STERILIZED PERITONEAL-DIALYSIS FLUIDS TOXIC IN-VITRO
    WIESLANDER, AP
    ANDREN, AHG
    NILSSONTHORELL, C
    MUSCALU, N
    KJELLSTRAND, PTT
    RIPPE, B
    PERITONEAL DIALYSIS INTERNATIONAL, 1995, 15 (08): : 348 - 352
  • [29] A COMPARISON BETWEEN THE EFFECTS OF ACETATE AND LACTATE IN PERITONEAL-DIALYSIS SOLUTIONS
    ROSSEN, B
    LADEFOGED, J
    SCANDINAVIAN JOURNAL OF UROLOGY AND NEPHROLOGY, 1982, 16 (03): : 279 - 281
  • [30] EFFECTS OF HYPERTONIC PERITONEAL-DIALYSIS SOLUTIONS ON NEUTROPHIL SUPEROXIDE PRODUCTION
    ZHOU, FQ
    MANAHAN, FJ
    YU, AW
    RAHMAN, MA
    NAWAB, ZM
    FISHER, KA
    ING, TS
    ARTIFICIAL ORGANS, 1990, 14 (06) : 410 - 412