ROLE OF BRONCHOALVEOLAR LAVAGE IN MECHANICALLY VENTILATED PATIENTS WITH SUSPECTED PNEUMONIA

被引:37
|
作者
VALLES, J
RELLO, J
FERNANDEZ, R
BLANCH, L
BAIGORRI, F
MESTRE, J
MATAS, L
MARIN, A
ARTIGAS, A
机构
[1] HOSP SABADELL, DEPT MICROBIOL, E-08208 SABADELL, SPAIN
[2] HOSP SABADELL, DEPT RESP DIS, E-08208 SABADELL, SPAIN
关键词
D O I
10.1007/BF01971305
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
To determine the usefulness of samples obtained by bronchoalveolar lavage (BAL) in establishing the diagnosis of ventilator-associated pneumonia, quantitative cultures of BAL and protected specimen brush (PSB) samples obtained via fiberoptic bronchoscope were compared in 42 patients with suspected ventilator-associated pneumonia. Direct examination of BAL fluid was also used to identify cells with intracellular organisms. Ventilator-associated pneumonia was diagnosed in 18 patients; a total of 39 microorganisms were recovered from BAL fluid and 29 from PSB specimens. Cultures of 21 BAL and 23 PSB specimens were sterile. Quantitative BAL and PSB cultures coincided in 76 % of cases. Sterile BAL and PSB cultures agreed in 87 % of cases. Cultures were completely discordant in only three cases. The sensitivity of BAL for diagnosis of ventilator-associated pneumonia using bacterial counts of greater than or equal to 10(4) cfu/ml was 89 %, and specificity was 100 %. In 14 of the 18 patients with ventilator-associated pneumonia, the percentage of cells containing intracellular organisms in specimens recovered by BAL was 11.6 % versus 0.45 % in patients without pneumonia (p < 0.05). In the remaining four patients, all of whom had Pseudomonas aeruginosa pneumonia, no intracellular organisms could be detected. Using a cut-off point of greater than or equal to 5 % of cells with intracellular organisms, the sensitivity and specificity for the early diagnosis of ventilator-associated pneumonia was 67 % and 96 %, respectively The results confirm the usefulness of the quantitative BAL culture (with a cut-off at 10(4) cfu/ml) for the diagnosis of ventilator-associated pneumonia. The identification of intracellular organisms in BAL fluid is a good early indicator of pneumonia, but the sensitivity of this technique may be lower for Pseudomonas aeruginosa infections.
引用
收藏
页码:549 / 558
页数:10
相关论文
共 50 条
  • [11] Non-bronchoscopic bronchoalveolar lavage in the microbiological diagnosis of pneumonia in mechanically ventilated patients
    Arora, SC
    Mudaliar, YM
    Lee, C
    Mitchell, D
    Iredell, J
    Lazarus, R
    ANAESTHESIA AND INTENSIVE CARE, 2002, 30 (01) : 11 - 20
  • [12] Concordance between two methods of bronchoalveolar lavage for the microbiological diagnosis of pneumonia in mechanically ventilated patients
    Agustin Velez, Lazaro
    Loaiza, Natalia
    Maria Gaviria, Lina
    Angelica Maya, Maria
    Vanessa Rueda, Zulma
    Teresita Correa, Luz
    Ortega, Jorge
    Ortega, Hector
    BIOMEDICA, 2008, 28 (04): : 551 - 561
  • [13] COMPARATIVE EFFICACY OF BRONCHOALVEOLAR LAVAGE AND TELESCOPING PLUGGED CATHETER IN THE DIAGNOSIS OF PNEUMONIA IN MECHANICALLY VENTILATED PATIENTS
    VIOLAN, JS
    DECASTRO, FR
    LUNA, JC
    BENITEZ, AB
    ALONSO, JLM
    CHEST, 1993, 103 (02) : 386 - 390
  • [14] THE ROLE OF BRONCHOALVEOLAR LAVAGE IN THE DIAGNOSIS OF SUSPECTED OPPORTUNISTIC PNEUMONIA
    ABRAMSON, MJ
    STONE, CA
    HOLMES, PW
    TAI, EH
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1987, 17 (04): : 407 - 412
  • [15] The IRIDICA PCR/Electrospray Ionization-Mass Spectrometry Assay on Bronchoalveolar Lavage for Bacterial Etiology in Mechanically Ventilated Patients with Suspected Pneumonia
    Stralin, Kristoffer
    Ehn, Fredrik
    Giske, Christian G.
    Ullberg, Mans
    Hedlund, Jonas
    Petersson, Johan
    Spindler, Carl
    Ozenci, Volkan
    PLOS ONE, 2016, 11 (07):
  • [16] QUANTITATIVE CULTURES OF PROTECTED BRUSH SPECIMENS AND BRONCHOALVEOLAR LAVAGE IN VENTILATED PATIENTS WITHOUT SUSPECTED PNEUMONIA
    DECASTRO, FR
    SOLE, J
    ELCUAZ, R
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1994, 149 (02) : 320 - 323
  • [17] Effects on Respiratory Mechanics of Bronchoalveolar Lavage in Mechanically Ventilated Patients
    Estella, Angel
    JOURNAL OF BRONCHOLOGY & INTERVENTIONAL PULMONOLOGY, 2010, 17 (03) : 228 - 231
  • [18] SAFETY OF BRONCHOALVEOLAR LAVAGE IN MECHANICALLY VENTILATED INFANTS
    BELAI, I
    TAEUSCH, HW
    WALTHER, FJ
    PEDIATRIC RESEARCH, 1994, 35 (04) : A325 - A325
  • [19] EVALUATION OF BRONCHOALVEOLAR LAVAGE FOR THE DIAGNOSIS OF BACTERIAL PNEUMONIA IN VENTILATED PATIENTS
    ROGERMOREAU, I
    DEBARBEYRAC, B
    DUCOUDRE, M
    HILBERT, G
    GBIKPIBENISSAN, G
    CARDINAUD, JP
    BEBEAR, C
    ANNALES DE BIOLOGIE CLINIQUE, 1992, 50 (08) : 587 - 591
  • [20] BRONCHOALVEOLAR LAVAGE (BAL) FOR DIAGNOSING BACTERIAL PNEUMONIA IN VENTILATED PATIENTS
    KONRAD, F
    DELLER, A
    BIGOS, K
    HEEG, K
    KILIAN, J
    ANAESTHESIST, 1990, 39 (01): : 53 - 59