PASSIVE RADON THORON PERSONAL DOSIMETER USING AN ELECTROSTATIC COLLECTOR AND A DIFFUSED-JUNCTION DETECTOR

被引:6
|
作者
BIGU, J [1 ]
RAZ, R [1 ]
机构
[1] ALPHA NUCL,MISSISSAUGA L4V 1H3,ONTARIO,CANADA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1985年 / 56卷 / 01期
关键词
ELECTROSTATIC DEVICES - Testing - RADON - Measurements;
D O I
10.1063/1.1138482
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The dosimeter basically consists of an electrostatic collector and an alpha-particle counting system with spectroscopy capabilities. Data can be retrieved during or after sampling by means of a microcomputer (Epson HX20) via a RS-232 communication interface unit. The dosimeter has been calibrated in a large (26 m**3) radon/thoron test facility. A linear relationship was found between the dosimeter's alpha-count and both radon gas concentration and radon daughter working level. The dosimeter is mounted on top of an ordinary miner's cap lamp battery and is ideally suited for personal monitoring in underground uranium mines and other working areas. The dosimeter presented here is a considerably improved version of an earlier prototype.
引用
收藏
页码:146 / 153
页数:8
相关论文
共 38 条
  • [21] POCKET ALARM DOSIMETER FOR PERSONAL RADIATION CONTROL USING SILICON DETECTOR
    YOSHIDA, Y
    ISHIKURA, T
    OKAMOTO, E
    NAGASE, Y
    JOURNAL OF THE ATOMIC ENERGY SOCIETY OF JAPAN, 1988, 30 (06): : 515 - 517
  • [22] Measurement of Indoor Thoron Gas Concentrations Using a Radon-Thoron Discriminative Passive Type Monitor: Nationwide Survey in Japan
    Sanada, Tetsuya
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (03) : 1 - 8
  • [23] Measurement of radon activity in air using electrostatic collection to the Timepix detector
    Mamedov, F.
    Cermak, P.
    Jakubek, J.
    Smolek, K.
    Stekl, I.
    Vlasek, J.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [24] Assessment of radon gas using passive dosimeter in Amman and Al-Rusaifa cities, Jordan
    Alqadi, M. K.
    Alzoubi, F. Y.
    Jaber, M. A.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2016, 14 (04): : 367 - 371
  • [25] Passive-Type Radon Monitor Constructed Using a Small Container for Personal Dosimetry
    Tamakuma, Yuki
    Kranrod, Chutima
    Suzuki, Takahito
    Watanabe, Yuki
    Ploykrathok, Thamaborn
    Negami, Ryoju
    Nugraha, Eka Djatnika
    Iwaoka, Kazuki
    Janik, Miroslaw
    Hosoda, Masahiro
    Tokonami, Shinji
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (16) : 1 - 11
  • [26] DETERMINATION OF THE ABSOLUTE RADON CONCENTRATION IN AIR USING AN ELECTROSTATIC METHOD AND CR-39 DETECTOR
    TETEREV, YG
    TRETYAKOVA, SP
    GOLOVCHENKO, AN
    ILIC, R
    SKVARC, J
    RADIATION MEASUREMENTS, 1995, 25 (1-4) : 645 - 646
  • [28] Determination of equilibrium factor between radon and its progeny using surface barrier detector for various shapes of passive radon dosimeters
    Jamil, K
    FazalurRehman
    Ali, S
    Khan, HA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 388 (1-2): : 267 - 272
  • [29] DEVELOPMENT OF WIDE-ENERGY RANGE PERSONAL NEUTRON DOSIMETER USING CR-39 TRACK DETECTOR
    OHGUCHI, H
    NAKAMURA, T
    APPLIED RADIATION AND ISOTOPES, 1995, 46 (6-7) : 509 - 510
  • [30] DEVELOPMENT OF HIGH-SENSITIVITY X-AND GAMMA-RAY PERSONAL DOSIMETER USING PHOTOSTIMULATED LUMINESCENT DETECTOR
    YAMADERA, A
    KIM, E
    MIYATA, T
    NAKAMURA, T
    APPLIED RADIATION AND ISOTOPES, 1995, 46 (6-7) : 467 - 468