Safety and effectiveness of a glistening-free single-piece hydrophobic acrylic intraocular lens (enVista)

被引:30
|
作者
Packer, Mark [1 ]
Fry, Luther [2 ]
Lavery, Kevin T. [3 ]
Lehmann, Robert [4 ]
McDonald, James [5 ]
Nichamin, Louis [6 ]
Bearie, Brian [7 ]
Hayashida, Jon [8 ]
Altmann, Griffith E. [8 ]
Khodai, Omid [8 ]
机构
[1] Oregon Hlth & Sci Univ, Dept Ophthalmol, Eugene, OR USA
[2] Univ Kansas, Med Ctr, Kansas City, KS 66103 USA
[3] Wayne State Univ, Detroit, MI USA
[4] Baylor Coll Med, Houston, TX 77030 USA
[5] Univ Arkansas Med Sci, Little Rock, AR 72204 USA
[6] Laurel Eye Clin, Brookville, PA USA
[7] Grand Rapids Eye Inst, Grand Rapids, MI USA
[8] Bausch & Lomb, Aliso Viejo, CA USA
来源
CLINICAL OPHTHALMOLOGY | 2013年 / 7卷
关键词
cataract surgery; enVista; glistenings; intraocular lens; hydrophobic acrylic;
D O I
10.2147/OPTH.S50499
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the safety and effectiveness of a single-piece hydrophobic acrylic intraocular lens (IOL; enVista model MX60; Bausch & Lomb, Rochester, NY, USA) when used to correct aphakia following cataract extraction in adults. Methods: This was a prospective case series (NCT01230060) conducted in private practices in the US. Eligible subjects were adult patients with age-related cataract amenable to treatment with standard phacoemulsification/extracapsular cataract extraction. With follow-up of 6 months, primary safety and effectiveness end points included the rates of US Food and Drug Administration (FDA)-defined cumulative and persistent adverse events and the percentage of subjects who achieved best-corrected visual acuity (BCVA) of 20/40 or better at final visit. To evaluate rotational stability, subjects were randomized (1: 1: 1: 1) to have the lens implanted in one of four axis positions in 45 degrees increments. Results: A total of 122 subjects were enrolled. The rate of cumulative and persistent adverse events did not significantly exceed historical controls, as per FDA draft guidance. At the final postoperative visit, all subjects (100%) achieved a BCVA of 20/40 compared with the FDA historical control of 96.7%. Rotation of the IOL between the two final follow-up visits was < 5 degrees for 100% of eyes, and refractive stability was demonstrated. A low evaluation of posterior capsule opacification score was demonstrated, and no glistenings of any grade were reported for any subject at any visit. Conclusion: This study demonstrated the safety and effectiveness of the MX60 IOL. Favorable clinical outcomes included preserved BCVA, excellent rotational and refractive stability, no glistenings, and a low evaluation of posterior capsule opacification score.
引用
收藏
页码:1905 / 1912
页数:8
相关论文
共 50 条
  • [41] Intraoperative explantation of two single-piece hydrophobic acrylic intraocular lenses due to surface deposits
    M S Hickman
    L Werner
    N Mamalis
    E Sung
    D Goldstein
    D T Vroman
    S K Pandey
    Eye, 2006, 20 : 1054 - 1060
  • [42] Evaluation of uveal and capsule biocompatibility of a single-piece hydrophobic acrylic intraocular lens with ultraviolet-ozone treatment on the posterior surface
    Farukhi, M. Aabid
    Werner, Liliana
    Kohl, Justin C.
    Gardiner, Gareth L.
    Ford, Joshua R.
    Cole, Scott C.
    Vasavada, Shail A.
    Noristani, Rozina
    Mamalis, Nick
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (05): : 1081 - 1087
  • [43] Intraocular Lens Position Following In-the-Bag Implantation of Single-Piece Versus Three-Piece Acrylic Intraocular Lenses
    Robert, Marie-Claude
    Harasymowycz, Paul
    OPHTHALMIC SURGERY LASERS & IMAGING, 2012, 43 (06) : 472 - 478
  • [44] Scleral fixation of a single-piece multifocal intraocular lens
    Can, Ertugrul
    Basaran, M. Resat
    Gul, Adem
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2013, 23 (02) : 249 - 251
  • [45] Intraoperative explantation of two single-piece hydrophobic acrylic intraocular lenses due to surface deposits
    Hickman, M. S.
    Werner, L.
    Mamalis, N.
    Sung, E.
    Goldstein, D.
    Vroman, D. T.
    Pandey, S. K.
    EYE, 2006, 20 (09) : 1054 - 1060
  • [46] Clinical Outcome of Ciliary Sulcus-Implanted Single-Piece Foldable Acrylic Intraocular Lens
    Choo, Hun Gu
    Lee, Jong Hyuck
    Kim, Sun Woong
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (05): : 752 - 756
  • [47] Functional Outcomes After Refractive Lens Exchange With Implantation of a Glistening-Free Diffractive Trifocal Intraocular Lens
    Khoramnia, Ramin
    Naujokaitis, Tadas
    Baur, Isabella D.
    Hassel, Oliver
    Henningsen, Nikola
    Reitemeyer, Emanuel
    Chychko, Lizaveta
    Labuz, Grzegorz
    Auffarth, Gerd U.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2024, 268 : 296 - 305
  • [48] Refractive stability of a new single-piece hydrophobic acrylic intraocular lens and corneal wound repair after implantation using a new automated intraocular lens delivery system
    Negishi, Kazuno
    Masui, Sachiko
    Torii, Hidemasa
    Nishi, Yasuyo
    Tsubota, Kazuo
    PLOS ONE, 2020, 15 (09):
  • [49] Reverse Optic Capture of the Single-Piece Acrylic Intraocular Lens in Eyes With Posterior Capsule Rupture
    Jones, Jason J.
    Oetting, Thomas A.
    Rogers, Gina M.
    Jin, George J. C.
    OPHTHALMIC SURGERY LASERS & IMAGING, 2012, 43 (06) : 480 - 488
  • [50] Migration of lens epithelial cells through haptic root of single-piece acrylic-foldable intraocular lens
    Sugita, M
    Kato, S
    Sugita, G
    Oshika, T
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2004, 137 (02) : 377 - 379