Rib orientation effects on heat transfer performance in forced convective boiling

被引:0
|
作者
Akhanda, MAR [1 ]
James, DD [1 ]
机构
[1] UMIST,DEPT MECH ENGN,MANCHESTER M60 1QD,LANCS,ENGLAND
关键词
rib orientation forced; convective boiling;
D O I
10.1080/00986449508936395
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The effects of rib orientation to the direction of flow on the heat transfer performance of ribbed surfaces in forced convective boiling have been investigated experimentally. Test surfaces were manufactured from a stainless steel plate of 1.60 mm thickness on to which transverse rectangular ribs were machined. Rib height, length and spacing were kept constant at 0.50 mm, 1.00 mm and 0.50 mm respectively and rib orientation to the direction of Bow was varied from 0 degrees to 135 degrees. In order to ensure good reproducibility of the experimental data, the effects of surface roughness were isolated by providing a constant surface micro-roughness for all test specimens and the effects of aging were also isolated. Experimental data are reported for heat transfer from ribbed surfaces to water boiling at atmospheric pressure for velocities ranging from 0.2 m/s to 1.4 m/s and inlet subcoolings from 5 degrees to 30 degrees C.
引用
收藏
页码:15 / 24
页数:10
相关论文
共 50 条
  • [31] EFFECTS OF NORMAL SURFACE VIBRATION ON LAMINAR FORCED CONVECTIVE HEAT TRANSFER
    SCANLAN, JA
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1958, 50 (10): : 1565 - 1568
  • [32] EFFECTS OF SUCTION THROUGH A SLIT ON FORCED CONVECTIVE HEAT-TRANSFER
    KOMORI, K
    INAGAKI, T
    KAGAKU KOGAKU RONBUNSHU, 1990, 16 (02) : 275 - 279
  • [33] HEAT TRANSFER IN FORCED CONVECTION FILM BOILING
    BROMLEY, LA
    LEROY, NR
    ROBBERS, JA
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1953, 45 (12): : 2639 - 2646
  • [34] Transient forced convective heat transfer: A review
    Padet, Jacques
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION 2007, VOL 8, PTS A AND B: HEAT TRANSFER, FLUID FLOWS, AND THERMAL SYSTEMS, 2008, : 1467 - 1478
  • [35] Forced convective heat transfer of nanofluids in microchannels
    Jung, Jung-Yeul
    Oh, Hoo-Suk
    Kwak, Ho-Young
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2009, 52 (1-2) : 466 - 472
  • [36] CRITICAL HEAT FLUX IN SATURATED FORCED CONVECTIVE BOILING WITH AN IMPINGING JET - (COEXISTENCE OF POOL AND FORCED CONVECTIVE BOILINGS).
    Monde, Masanori
    Furukawa, Yohichi
    Nippon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 1987, 53 (485): : 199 - 203
  • [37] Effect of rib diameter on flow boiling heat transfer with staggered rib arrays in a heat sink
    Qi, Di
    He, Jing
    Xu, Yongsheng
    Lin, Mei
    Wang, Qiuwang
    ENERGY, 2022, 239
  • [38] Critical heat flux in saturated forced convective boiling with an impinging jet coexistence of pool and forced convective boilings
    Monde, Masanori
    Furukawa, Yohichi
    Heat Transfer - Japanese Research, 1988, 17 (05): : 81 - 91
  • [39] Experimental study of forced convective boiling heat transfer for refrigerants in a horizontal, spirally grooved steel tube
    Momoki, S
    Higashiiue, S
    Shigechi, T
    Yamaguchi, T
    Mori, H
    Proceedings of ECOS 2005, Vols 1-3: SHAPING OUR FUTURE ENERGY SYSTEMS, 2005, : 897 - 904
  • [40] Forced convective boiling of binary mixtures in annular flow. Part II: heat and mass transfer
    Barbosa, JR
    Hewitt, GF
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2001, 44 (08) : 1475 - 1484