ROUTINE MONITORING IN PATIENTS WITH FREE TISSUE TRANSFER BY LASER-DOPPLER FLOWMETRY

被引:16
|
作者
MAILAENDER, P [1 ]
MACHENS, HG [1 ]
WAURICK, R [1 ]
RIECK, B [1 ]
BERGER, A [1 ]
机构
[1] HANNOVER MED SCH,DEPT PLAST HAND & RECONSTRUCT,PODBIELSKI 380,D-30659 HANNOVER,GERMANY
关键词
D O I
10.1002/micr.1920150311
中图分类号
R61 [外科手术学];
学科分类号
摘要
The use of laser Doppler flowmetry (LDF) was tested in 108 consecutive patients, who underwent free tissue transfer at our institution between December, 1988, and June, 1990. Sixteen patients (14.8%) suffered vascular complications, which could be detected in all cases earlier by LDF than by clinical examination alone. LDF therefore prompted faster surgical intervention in these cases, allowing flap salvation in 9.3% (n = 10). Difficulties had to be noted in diagnosing venous thrombosis by means of the LDF due to sometimes unspecific alterations in LDF signals. Technical improvement of LDF might lead to a higher diagnostic accuracy if venous thrombosis occurs. (C) 1994 Wiley-Liss, Inc.
引用
收藏
页码:196 / 202
页数:7
相关论文
共 50 条
  • [31] DIAPHRAGMATIC MICROCIRCULATION MEASURED BY LASER-DOPPLER FLOWMETRY IN THE RAT
    CHANG, HY
    CHEN, CR
    HUSSAIN, SNA
    JOURNAL OF APPLIED PHYSIOLOGY, 1995, 78 (04) : 1225 - 1233
  • [32] EVALUATION OF ANGIOGENESIS IN CHRONIC INFLAMMATION BY LASER-DOPPLER FLOWMETRY
    ORLANDI, C
    DUNN, CJ
    CUTSHAW, LG
    CLINICAL SCIENCE, 1988, 74 (02) : 119 - 121
  • [33] CHOROIDAL BLOOD-FLOW BY LASER-DOPPLER FLOWMETRY
    RIVA, CE
    PETRIG, BL
    OPTICAL ENGINEERING, 1995, 34 (03) : 746 - 752
  • [34] Absorption and scattering coefficient dependence of laser-Doppler flowmetry models for large tissue volumes
    Binzoni, T
    Leung, TS
    Rüfenacht, D
    Delpy, DT
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (02): : 311 - 333
  • [35] LASER-DOPPLER FLOWMETRY IN MONITORING REGULATION OF RAPID MICROCIRCULATORY CHANGES IN SPINAL-CORD
    LINDSBERG, PJ
    JACOBS, TP
    FRERICHS, KU
    HALLENBECK, JM
    FEUERSTEIN, GZ
    AMERICAN JOURNAL OF PHYSIOLOGY, 1992, 263 (01): : H285 - H292
  • [36] MONITORING OF SPINAL-CORD BLOOD-FLOW (SCBF) WITH LASER-DOPPLER FLOWMETRY
    LINDSBERG, PJ
    ONEILL, JT
    PAAKKARI, IA
    HALLENBECK, JM
    FEUERSTEIN, G
    STROKE, 1989, 20 (01) : 134 - 134
  • [37] ACUTE EFFECTS OF LOCAL TISSUE TRAUMA ON SKIN PERFUSION EVALUATED WITH LASER-DOPPLER FLOWMETRY
    STAXRUD, LE
    KVERNEBO, K
    SALERUD, EG
    MICROVASCULAR RESEARCH, 1991, 42 (02) : 179 - 186
  • [38] Laser-Doppler flowmetry for monitoring microvascular disfunction caused by acute lower extremity ischemia
    Kania, M
    Staszkiewicz, W
    Maniewski, R
    Liebert, A
    Kwietniak, Z
    Madycki, G
    20TH EUROPEAN CONFERENCE ON MICROCIRCULATION, 1998, : 347 - 351
  • [39] CONTINUOUS MONITORING OF POSTTRAUMATIC CEREBRAL BLOOD-FLOW USING LASER-DOPPLER FLOWMETRY
    MUIR, JK
    BOERSCHEL, M
    ELLIS, EF
    JOURNAL OF NEUROTRAUMA, 1992, 9 (04) : 355 - 362
  • [40] Monitoring of Free Flaps with Combined Tissue Spectrophotometry and Laser Doppler Flowmetry in an Animal Experimental Model
    Berggren-Olsen, Mette Marie
    Rauff-Mortensen, Andreas
    Holst, Rene
    Houlind, Kim Christian
    Birke-Sorensen, Hanne
    JOURNAL OF RECONSTRUCTIVE MICROSURGERY, 2017, 33 (08) : 579 - 586