SHUNT EFFECT OF GAS-COMPRESSION INSIDE PNEUMOTACHOGRAPHS DURING FORCED-OSCILLATIONS

被引:3
|
作者
LOUIS, B
HARF, A
LORINO, H
ISABEY, D
机构
[1] FAC MED CRETEIL,INSERM,U296,8 AVE GEN SARRAIL,F-94010 CRETEIL,FRANCE
[2] FAC MED CRETEIL,DEPT PHYSIOL,F-94010 CRETEIL,FRANCE
关键词
RESPIRATORY IMPEDANCE; SHUNT ADMITTANCE; FLOW REDISTRIBUTION; FREQUENCE RESPONSE; WAVE TUBE IMPEDANCE;
D O I
10.1152/jappl.1991.70.1.143
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Determination of the frequency response of pneumotachographs is needed whenever they are used to measure high-frequency flows, such as in the forced oscillation method. When screen and capillary pneumotachographs are calibrated using an adiabatic compression in a closed box as a reference impedance, they can be adequately described by a series of inertial-resistive elements. However, this type of reference impedance strongly differs from the actual respiratory impedance (ZL). We studied the frequency response of pneumotachographs up to 250 Hz in reference to the impedance of a compressible gas oscillating in a long tube, taken as a more generalizable model of actual ZL. We found that, with this device, the series restance-inertance models fail to describe the frequency response of the pneumotachograph. However, when compressible effects in the pneumotachograph are taken into account by adding to the resistive models a compliance (Cpn) corresponding to the compression in half of the inner volume of the pneumotachograph, the agreement with experiments becomes satisfactory. Gas compression-related phenomena were demonstrated to be negligible only when the parameter omega-Cpn [ZL[ is much smaller than 1 (omega-pulsation). Results obtained in normal humans have shown that such a correction is required above 100 Hz. Similar correction at lower frequency might also be necessary in cases of large respiratory impedance (e.g., babies, subjects with pathological lungs, and intubated subjects).
引用
收藏
页码:143 / 151
页数:9
相关论文
共 40 条
  • [31] EFFECT OF LOW GAS PRESSURE ON THE PHYSICAL PROPERTIES OF OUTBURST COAL DURING UNIAXIAL COMPRESSION
    Yankun Ma
    Ke Yang
    Deren Chen
    Zhao Aohan
    Journal of Mining Science, 2021, 57 : 45 - 56
  • [32] Investigating the effect of cardiac oscillations and deadspace gas mixing during apnea using computer simulation
    Laviola, Marianna
    Das, Anup
    Chikhani, Marc
    Bates, Declan G.
    Hardman, Jonathan G.
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 337 - 340
  • [33] HIGH-DENSITY BREATHING SYNDROME .1. OSCILLATIONS ON FLOW-VOLUME CURVES DURING FORCED BREATHING IN DENSE GAS MEDIA
    GULYAR, SA
    ILJIN, VN
    BOLTYCHEV, IR
    FIZIOLOGICHESKII ZHURNAL, 1991, 37 (04): : 19 - 26
  • [34] THE EFFECT OF PATH-LENGTH ON GAS-TRANSPORT DURING HIGH-FREQUENCY OSCILLATIONS (HFO)
    FORKERT, L
    CARMAN, J
    FINKLER, J
    FEDERATION PROCEEDINGS, 1985, 44 (04) : 1026 - 1026
  • [35] THE EFFECT OF LUNG-VOLUME ON REGIONAL GAS-TRANSPORT DURING HIGH-FREQUENCY OSCILLATIONS
    FORKERT, L
    BURKS, JE
    RESPIRATION PHYSIOLOGY, 1984, 58 (03): : 279 - 287
  • [36] Effect of Forced Gas Flow During Lightning Impulse Testing of CO2 in a Weakly Inhomogeneous Field
    Subhana, Arik
    Stoa-Aanensen, Nina Sasaki
    Kragset, Jonas
    Mauseth, Frank
    2024 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATIONS, ICHVE 2024, 2024,
  • [37] Effect of thoracic gas compression and bronchodilation on the assessment of expiratory flow limitation during exercise in healthy humans
    Guenette, Jordan A.
    Dominelli, Paolo B.
    Reeve, Sabrina S.
    Durkin, Christopher M.
    Eves, Neil D.
    Sheel, A. William
    RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2010, 170 (03) : 279 - 286
  • [38] Effect of initial gas bubble composition on detection of inducible intrapulmonary arteriovenous shunt during exercise in normoxia, hypoxia, or hyperoxia
    Elliott, Jonathan E.
    Choi, Yujung
    Laurie, Steven S.
    Yang, Ximeng
    Gladstone, Igor M.
    Lovering, Andrew T.
    JOURNAL OF APPLIED PHYSIOLOGY, 2011, 110 (01) : 35 - 45
  • [39] Estimate measurement of soot diameter and volume fraction inside the bowl of a direct-injection-compression-ignition engine:: Effect of the exhaust gas recirculation
    Boiarciuc, Andrei
    Foucher, Fabrice
    Mounaim-Rousselle, Christine
    Pajot, Olivier
    COMBUSTION SCIENCE AND TECHNOLOGY, 2007, 179 (08) : 1631 - 1648
  • [40] Estimating the effect of lung collapse and pulmonary shunt on gas exchange during breath-hold diving: The Scholander and Kooyman legacy
    Fahlman, A.
    Hooker, S. K.
    Szowka, A.
    Bostrom, B. L.
    Jones, D. R.
    RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2009, 165 (01) : 28 - 39