THE EFFECTS OF VISUAL INPUT ON OPEN-LOOP AND CLOSED-LOOP POSTURAL CONTROL MECHANISMS

被引:272
|
作者
COLLINS, JJ [1 ]
DE LUCA, CJ [1 ]
机构
[1] BOSTON UNIV, DEPT BIOMED ENGN, BOSTON, MA 02215 USA
关键词
POSTURAL CONTROL; VISION; CLOSED-LOOP CONTROL; OPEN-LOOP CONTROL; CENTER OF PRESSURE; STABILOGRAMS; HUMAN;
D O I
10.1007/BF00241972
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
In an earlier posturographic investigation (Collins and De Luca 1993) it was proposed that open-loop and closed-loop control mechanisms are involved in the regulation of undisturbed, upright stance. In this study, stabilogram-diffusion analysis was used to examine how visual input affects the operational characteristics of these control mechanisms. Stabilogram-diffusion analysis leads to the extraction of repeatable center-of-pressure (COP) parameters that can be directly related to the resultant steady-state behavior and functional interaction of the neuromuscular mechanisms underlying the maintenance of erect posture. Twenty-five healthy male subjects (aged 19-30 years) were included in the study. An instrumented force platform was used to measure the time-varying displacements of the COP under each subject's feet during quiet standing. The subjects were tested under eyes-open and eyes-closed conditions. The COP trajectories were analyzed as one-dimensional and two-dimensional random walks, according to stabilogram-diffusion analysis. Using this technique, it was found that visual input affects the performance of the postural control system in one of two different ways either it significantly modifies the steady-state behavior of the open-loop postural control mechanisms, or it significantly alters the characteristics of the other closed-loop feedback mechanisms that are involved in balance control. This result is interpreted as an indication that the visual system is integrated into the postural control system in one of two different ways. The experimental population was roughly evenly divided between these two schemes. For the first group (13 of 25 subjects), visual input principally caused a decrease in the ''effective'' stochastic activity of the open-loop control mechanisms in both the mediolateral and anteroposterior directions. For the second group (12 of 25 subjects), visual input caused an increase in the effective stochastic activity and uncorrelated behavior of the closed-loop control mechanisms in the anteroposterior direction only. On the basis of these results, it is hypothesized that visual input, in both schemes, serves to decrease the stiffness of the musculoskeletal system. In the former case, this may be accomplished by decreasing the level of muscular activity across the joints of the lower limb, whereas, in the latter case, reduced stiffness may be achieved by reducing the gain(s) of the other postural feedback mechanisms, i.e., the proprioceptive and/or vestibular systems. Using stabilogram-diffusion analysis, it was also found that the two groups of subjects behaved similarly under eyes-closed conditions. This result suggests that the open-loop postural control mechanisms and reflex-based feedback systems, respectively, of healthy, young individuals are organized in functionally equivalent ways.
引用
收藏
页码:151 / 163
页数:13
相关论文
共 50 条
  • [31] OPEN-LOOP HYDROSTATIC DRIVES APPROACH CLOSED-LOOP PERFORMANCE
    SMITH, PM
    MACHINE DESIGN, 1984, 56 (11) : 79 - 82
  • [32] A combined open-loop and closed-loop production planning scheme
    Hennet, JC
    MANUFACTURING, MODELING, MANAGEMENT AND CONTROL, PROCEEDINGS, 2001, : 279 - 284
  • [33] A Carrier Synchronization Algorithm Combine Open-loop and Closed-loop
    Wang, Hong-zhuo
    Yan, Jun-ji
    Liu, Ce-lun
    INTERNATIONAL CONFERENCE ON ADVANCES IN MANAGEMENT SCIENCE AND ENGINEERING (AMSE 2015), 2015, : 164 - 168
  • [34] The effect of a pictorial illusion on closed-loop and open-loop prehension
    Westwood, DA
    Heath, M
    Roy, EA
    EXPERIMENTAL BRAIN RESEARCH, 2000, 134 (04) : 456 - 463
  • [35] THE EFFECT OF MENTAL EFFORT ON OPEN-LOOP AND CLOSED-LOOP ACCOMMODATION
    WINN, B
    GILMARTIN, B
    MORTIMER, LC
    EDWARDS, NR
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1991, 11 (04) : 335 - 339
  • [36] Servo, open-loop, and closed-loop drive in one package
    Control Engineering, 1996, 43 (04):
  • [37] The effect of a pictorial illusion on closed-loop and open-loop prehension
    David A. Westwood
    Matthew Heath
    Eric A. Roy
    Experimental Brain Research, 2000, 134 : 456 - 463
  • [38] HEMISPHERIC-ASYMMETRY OF OPEN-LOOP AND CLOSED-LOOP MOVEMENT
    HAALAND, KY
    HARRINGTON, D
    JOURNAL OF CLINICAL AND EXPERIMENTAL NEUROPSYCHOLOGY, 1988, 10 (01) : 23 - 23
  • [39] General control landscape structure shared by open-loop and closed-loop quantum control approaches
    Brif, Constantin
    Pechen, Alexander
    Wu, Rebing
    Chakrabarti, Raj
    Rabitz, Herschel
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2011, 242
  • [40] Closed-loop and open-loop control of posture and movement during human trunk bending
    Alexandrov, A. V.
    Frolov, A. A.
    BIOLOGICAL CYBERNETICS, 2011, 104 (06) : 425 - 438