A comparison of conventional endotracheal tube with silicone wire-reinforced tracheal tube for intubation through intubating laryngeal mask airway

被引:12
|
作者
Shah, Veena R. [1 ]
Bhosale, Guruprasad P. [1 ]
Mehta, Tanu [1 ]
Parikh, Geeta P. [1 ]
机构
[1] Dr HL Trivedi Inst Transplantat Sci, Smt KM Mehta & Smt GR Doshi Inst Kidney Dis & Res, Dept Anesthesia & Crit Care, Civil Hosp Campus, Ahmadabad 380016, Gujarat, India
关键词
Intubating laryngeal mask airway; polyvinyl chloride tracheal tube; silicon wire-reinforced tracheal tube;
D O I
10.4103/1658-354X.130702
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: A specially designed wire-reinforced endotracheal tube -the Fastrach silicone tube (FTST) designed to facilitate endotracheal intubation through intubating laryngeal mask airway (ILMA) are expensive and not readily available. Hence, it is worth considering alternative such as polyvinyl chloride tracheal tube (PVCT), which is disposable, cheap and easily available. The aim of the present study was to compare the clinical performance of FTST with conventional PVCT for tracheal intubation through ILMA. Methods: After informed consent, 60 ASA I-II adults with normal airway undergoing elective surgery were randomly allocated to undergo blind tracheal intubation through ILMA with a FTST or conventional PVCT. Overall success rate, ease of insertion, number of attempts for successful intubation, critical incidence during intubation and post-operative sore throat were compared. Results: The overall success rate with FTST was 96.63% and 93.33% with PVCT; in addition, the first attempt success rate was 86.25% with FTST compared to 82.14% with PVCT. The time taken for intubation was 18.6 +/- 6.8 s. in FTST group and 22.42 +/- 8.5 s. in PVCT group. Incidence of sore throat was 21.42% in PVCT group compared with 6.89% in FTST group. Conclusion: Blind tracheal intubation through an ILMA with the conventional PVCT instead of FTST is a feasible alternative in patients with normal airways.
引用
收藏
页码:183 / 187
页数:5
相关论文
共 50 条
  • [1] Ease of endotracheal intubation with the conventional polyvinyl chloride endotracheal tube versus wire-reinforced flexometallic tube through the intubating laryngeal mask airway: A comparative study
    Kalvapudi, Devaki
    Archana, K. N.
    Swamy, Akshay Hiryur Manjunatha
    Kumararadhya, Girish Bandigowdanahalli
    Shivakumar, K. G.
    ANNALS OF AFRICAN MEDICINE, 2024, 23 (01) : 70 - 75
  • [2] Endotracheal intubation through the intubating laryngeal mask airway (LMA-Fastrach (TM)): A randomized study of LMA-Fastrach (TM) wire-reinforced silicone endotracheal tube versus conventional polyvinyl chloride tracheal tube
    Sharma, Megha U.
    Gombar, Satinder
    Gombar, Kanti K.
    Singh, Baljit
    Bhatia, Nidhi
    INDIAN JOURNAL OF ANAESTHESIA, 2013, 57 (01) : 19 - 24
  • [3] A comparison of a silicone wire-reinforced tube with the parker and polyvinyl chloride tubes for tracheal intubation through an intubating laryngeal mask airway in patients with normal airways undergoing general anesthesia
    Kanazi, Ghassan E.
    El-Khatib, Mohammed
    Nasr, Viviane G.
    Kaddoum, Romeo
    Al-Alami, Achir
    Baraka, Anis S.
    Ayoub, Chakib M.
    ANESTHESIA AND ANALGESIA, 2008, 107 (03): : 994 - 997
  • [4] Mallinckrodt reinforced tube for tracheal intubation through the intubating laryngeal mask
    Takashi Asai
    Canadian Journal of Anaesthesia, 1998, 45 : 1221 - 1222
  • [5] Mallinckrodt reinforced tube for tracheal intubation through the intubating laryngeal mask
    Asai, T
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1998, 45 (12): : 1221 - 1222
  • [6] Comparison of a polyvinyl chloride tube with a wire-reinforced tube for tracheal intubation through the SaCoVLM video laryngeal mask airway: protocol for a randomised controlled study
    Gao, Zhongquan
    Guo, Yongle
    Gao, Xiaojun
    Wang, Weiwei
    Zhang, Min
    Liu, Meng Jie
    Chen, Lina
    Liu, Yang
    Zhang, Xiaoning
    Sun, Yongtao
    Wang, Yuelan
    BMJ OPEN, 2022, 12 (12):
  • [7] Validation of tracheal intubation of wire-reinforced endotracheal tube with ultrasonography
    Inangil, Gokhan
    Deniz, Suleyman
    Temircan, Sedat
    Bakal, Omer
    Sen, Huseyin
    Ozkan, Sezai
    SIGNA VITAE, 2018, 14 (02) : 20 - 23
  • [8] Submeutal intubation with reinforced tube for intubating laryngeal mask airway
    Kim, YJ
    Lee, JS
    Kim, HJ
    Ha, JY
    Park, H
    Han, DW
    YONSEI MEDICAL JOURNAL, 2005, 46 (04) : 571 - 574
  • [9] A comparison of the intubating laryngeal mask tracheal tube with a standard tracheal tube for fibreoptic intubation
    Lucas, DN
    Yentis, SM
    ANAESTHESIA, 2000, 55 (04) : 358 - 361
  • [10] COMPARISON OF THE REINFORCED LARYNGEAL MASK AIRWAY AND ENDOTRACHEAL TUBE INTUBATION IN ADULT TONSILLECTOMY
    Ali, Chaudhry Amjad
    Imam, Syed Musharraf
    Anwar, Khursheed
    Sajjad, Rabia
    GOMAL JOURNAL OF MEDICAL SCIENCES, 2014, 12 (01): : 2 - 6