Endotracheal intubation through the intubating laryngeal mask airway (LMA-Fastrach (TM)): A randomized study of LMA-Fastrach (TM) wire-reinforced silicone endotracheal tube versus conventional polyvinyl chloride tracheal tube

被引:11
|
作者
Sharma, Megha U. [2 ]
Gombar, Satinder [1 ]
Gombar, Kanti K. [3 ]
Singh, Baljit [2 ]
Bhatia, Nidhi [4 ]
机构
[1] Govt Med Coll & Hosp, Dept Anesthesia & Intens Care, Chandigarh, India
[2] GB Pant Hosp, New Delhi, India
[3] INSCOL, Dept Crit Care, Chandigarh, India
[4] Post Grad Inst Med Educ & Res, Chandigarh, India
关键词
Fastrach; intubating laryngeal mask airway; polyvinyl chloride; tracheal intubation;
D O I
10.4103/0019-5049.108555
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Context: A wire-reinforced silicone tube (LMA-Fastrach T endotracheal tube) is specially designed for tracheal intubation using intubating laryngeal mask airway (ILMA). However, conventional polyvinyl chloride (PVC) tracheal tubes have also been used with ILMA to achieve tracheal intubation successfully. Aim: To evaluate the success of tracheal intubation using the LMA-Fastrach T tracheal tube versus conventional PVC tracheal tube through ILMA. Settings and Design: Two hundred adult ASA physical status I/II patients, scheduled to undergo elective surgery under general anaesthesia requiring intubation, were randomly allocated into two groups. Methods: The number of attempts, time taken, and manoeuvres employed to accomplish tracheal intubation were compared using conventional PVC tubes (group I) and LMA-Fastrach T wire-reinforced silicone tubes (groupII). Intraoperative haemodynamic changes and evidence of trauma and postoperative incidence of sore throat and hoarseness, were compared between the groups. Statistical Analysis: The data was analyzed using two Student's t test and Chi-squaretest for demographics and haemodynamic parameters. Mann Whitney U test was used for comparison of time taken for endotracheal tube insertion. Fisher's exact test was used to compare postoperative complications. Results: Rate of successful tracheal intubation and haemodynamic variables were comparable between the groups. Time taken for tracheal intubation and manoeuvres required to accomplish successful endotracheal intubation, however, were significantly greater in group I than group II (14.71 +/- 6.21 s and 10.04 +/- 4.49 s, respectively (P< 0.001), and 28% in group I and 3% in group II, respectively (P<0.05)). Conclusion: Conventional PVC tube can be safely used for tracheal intubation through the ILMA.
引用
收藏
页码:19 / 24
页数:6
相关论文
共 20 条
  • [1] Submental Intubation with reinforced tube for intubating Laryngeal Mask Airway (LMA-Fastrach™ ETT)
    Kim, K. -J.
    Lee, S. H.
    Kim, H.
    Kim, H. -J.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2004, 21 : 66 - 66
  • [2] Hidden damage to a reinforced LMA-Fastrach™ endotracheal tube
    Mesa, A
    Miguel, R
    ANESTHESIA AND ANALGESIA, 2000, 90 (05): : 1250 - 1251
  • [3] Hidden damage to a reinforced LMA-Fastrach™ endotracheal tube -: Response
    King, KP
    Stolp, B
    Borel, C
    ANESTHESIA AND ANALGESIA, 2000, 90 (05): : 1251 - 1251
  • [4] Tracheal intubation through the intubating laryngeal mask airway (LMA-Fastrach™) in patients with difficult airways
    Fukutome, T
    Amaha, K
    Nakazawa, K
    Kawamura, T
    Noguchi, H
    ANAESTHESIA AND INTENSIVE CARE, 1998, 26 (04) : 387 - 391
  • [5] Using the intubating laryngeal mask airway (LMA-Fastrach™) for blind endotracheal intubation in patients undergoing cervical spine operation
    Nakazawa, K
    Tanaka, N
    Ishikawa, S
    Ohmi, S
    Ueki, M
    Saitoh, Y
    Makita, K
    Amaha, K
    ANESTHESIA AND ANALGESIA, 1999, 89 (05): : 1319 - 1321
  • [6] A comparison of conventional endotracheal tube with silicone wire-reinforced tracheal tube for intubation through intubating laryngeal mask airway
    Shah, Veena R.
    Bhosale, Guruprasad P.
    Mehta, Tanu
    Parikh, Geeta P.
    SAUDI JOURNAL OF ANAESTHESIA, 2014, 8 (02) : 183 - 187
  • [7] High cuff pressure in the silicone endotracheal tube of the LMA-Fastrach: implications for patient safety
    Suneel, Puthuvassery Raman
    Koshy, Thomas
    Unnikrishnan, Koniparambil Pappu
    JOURNAL OF CLINICAL ANESTHESIA, 2011, 23 (08) : 666 - 667
  • [8] Ease of endotracheal intubation with the conventional polyvinyl chloride endotracheal tube versus wire-reinforced flexometallic tube through the intubating laryngeal mask airway: A comparative study
    Kalvapudi, Devaki
    Archana, K. N.
    Swamy, Akshay Hiryur Manjunatha
    Kumararadhya, Girish Bandigowdanahalli
    Shivakumar, K. G.
    ANNALS OF AFRICAN MEDICINE, 2024, 23 (01) : 70 - 75
  • [9] I-gel™ Versus LMA-Fastrach™ Supraglottic Airway for Flexible Bronchoscope-Guided Tracheal Intubation Using a Parker (GlideRite™) Endotracheal Tube: A Randomized Controlled Trial
    Moore, Alex
    Gregoire-Bertrand, Felix
    Massicotte, Nathalie
    Gauthier, Alain
    Lallo, Alexandre
    Ruel, Monique
    Todorov, Alexandre
    Girard, Francois
    ANESTHESIA AND ANALGESIA, 2015, 121 (02): : 430 - 436
  • [10] Comparison of blind tracheal intubation through the intubating laryngeal mask airway (LMA Fastrach™) and the Air-Q™
    Karim, Y. M.
    Swanson, D. E.
    ANAESTHESIA, 2011, 66 (03) : 185 - 190