HEATING PATTERNS PRODUCED IN HUMANS BY 433.92 MHZ ROUND FIELD APPLICATOR AND 915MHZ CONTACT APPLICATOR

被引:0
|
作者
LEHMANN, JF [1 ]
DELATEUR, BJ [1 ]
STONEBRIDGE, JB [1 ]
机构
[1] UNIV WASHINGTON,SCH MED,DEPT REHABIL MED,SEATTLE,WA 98195
来源
关键词
D O I
暂无
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
引用
收藏
页码:442 / 448
页数:7
相关论文
共 30 条
  • [11] HEATING CHARACTERISTICS OF A 430 MHZ MICROWAVE-HEATING SYSTEM WITH A LENS APPLICATOR IN PHANTOMS AND MINIATURE PIGS
    MATSUDA, T
    TAKATSUKA, S
    NIKAWA, Y
    KIKUCHI, M
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1990, 6 (03) : 685 - 696
  • [12] Compact Microwave Applicator for Thermal Therapy of Breast Cancer: Comparative Assessment of Arrays Operating at 434 and 915 MHz
    Garcia-Miquel, Aleix
    Curto, Sergio
    Vidal, Neus
    Lopez-Villegas, Jose M.
    Prakash, Punit
    2016 10TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION (EUCAP), 2016,
  • [13] POWER DEPOSITION PATTERNS AND THERMAL DISTRIBUTIONS FROM A NEW 434-MHZ APPLICATOR
    IBBOTT, GS
    LEE, NA
    STRIEBY, RA
    RADIATION RESEARCH, 1982, 91 (02) : 415 - 415
  • [14] CHANGES IN HEATING PATTERNS DUE TO PERTURBATIONS BY THERMOMETER PROBES AT 915 AND 434 MHZ
    CHAN, KW
    CHOU, CK
    MCDOUGALL, JA
    LUK, KH
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1988, 4 (04) : 447 - 456
  • [15] HEATING PATTERNS FOR AN ARRAY OF 915 MHZ RECTANGULAR WAVE-GUIDE APPLICATORS
    WYSLOUZIL, W
    KASHYAP, S
    DAIEN, DM
    JOURNAL OF MICROWAVE POWER AND ELECTROMAGNETIC ENERGY, 1987, 22 (04) : 213 - 220
  • [16] Characteristics and performance evaluation of the capacitive Contact Flexible Microstrip Applicator operating at 70 MHz for external hyperthermia
    van Wieringen, Niek
    Wiersma, Jan
    Vording, Paul Zum Vorde Sive
    Oldenborg, Sabine
    Gelvich, Edward A.
    Mazokhin, Vladimir N.
    van Dijk, Jan D. P.
    Crezee, Johannes
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2009, 25 (07) : 542 - 553
  • [17] COMPARISON OF HEATING PATTERNS FOR 915 OR 2450 MHZ MICROWAVES IN BRAIN PHANTOM AND IN THE CANINE BRAIN
    HENDERSON, SD
    JOHNSTON, RL
    MARCHOSKY, JA
    EMAMI, BN
    MEDICAL PHYSICS, 1985, 12 (05) : 671 - 671
  • [18] CLINICAL RESEARCH INTO HYPERTHERMIA TREATMENT OF CANCER USING A 430 MHZ MICROWAVE-HEATING SYSTEM WITH A LENS APPLICATOR
    MATSUDA, T
    KIKUCHI, M
    TANAKA, Y
    HIRAOKA, M
    NISHIMURA, Y
    AKUTA, K
    TAKAHASHI, M
    ABE, M
    FUWA, N
    MORITA, K
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1991, 7 (03) : 425 - 440
  • [19] CAPACITIVE HEATING OF PHANTOM AND HUMAN-TUMORS WITH AN 8 MHZ RADIOFREQUENCY APPLICATOR (THERMOTRON RF-8)
    SONG, CW
    RHEE, JG
    LEE, CKK
    LEVITT, SH
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1986, 12 (03): : 365 - 372
  • [20] LOW-FREQUENCY RF HYPERTHERMIA .4. A 27 MHZ HYBRID APPLICATOR FOR LOCALIZED DEEP TUMOR HEATING
    FRANCONI, C
    RAGANELLA, L
    TIBERIO, CA
    BEGNOZZI, L
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (03) : 287 - 293