EFFECTS OF QUANTIZATION OF TIME-OF-FLIGHT (TOF) MEASUREMENTS ON IMAGE SIGNAL-TO-NOISE RATIO IN TOF EMISSION TOMOGRAPHY

被引:2
|
作者
POLITTE, DG
HOLMES, TJ
SNYDER, DL
机构
关键词
D O I
10.1109/TNS.1983.4332364
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
引用
收藏
页码:720 / 722
页数:3
相关论文
共 50 条
  • [31] Relationship between the image quality and noise-equivalent count in time-of-flight positron emission tomography
    Akira Maebatake
    Go Akamatsu
    Kenta Miwa
    Yuji Tsutsui
    Kazuhiko Himuro
    Shingo Baba
    Masayuki Sasaki
    Annals of Nuclear Medicine, 2016, 30 : 68 - 74
  • [32] Relationship between the image quality and noise-equivalent count in time-of-flight positron emission tomography
    Maebatake, Akira
    Akamatsu, Go
    Miwa, Kenta
    Tsutsui, Yuji
    Himuro, Kazuhiko
    Baba, Shingo
    Sasaki, Masayuki
    ANNALS OF NUCLEAR MEDICINE, 2016, 30 (01) : 68 - 74
  • [33] THE INCORPORATION OF TIME-OF-FLIGHT MEASUREMENTS INTO POSITRON EMISSION COMPUTED-TOMOGRAPHY
    JACKSON, PC
    INTERNATIONAL JOURNAL OF NUCLEAR MEDICINE & BIOLOGY, 1982, 9 (02): : 129 - 133
  • [34] IMAGE QUALITY OF RADIOGRAPHIC SYSTEMS AS EVALUATED BY DIRECT SIGNAL-TO-NOISE RATIO MEASUREMENTS
    BOLLEN, R
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1985, 535 : 195 - 199
  • [35] SIGNAL-TO-NOISE ENHANCEMENT OF NEUTRAL-ION CORRELATION-MEASUREMENTS FOR TANDEM TIME-OF-FLIGHT MASS-SPECTROMETRY
    STROBEL, FH
    RUSSELL, DH
    ANALYTICAL CHEMISTRY, 1992, 64 (22) : 2879 - 2881
  • [36] Signal-to-Noise Ratio Equalized Filtered Back-Projection for Positron Emission Tomography
    Watson, Charles C.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (01) : 108 - 115
  • [37] Direct Time-of-Flight (d-ToF) Pulsed LiDAR Sensor With Simultaneous Noise and Interference Suppression
    Dabidian, Sobhan
    Jami, Sadra Tafaghodi
    Kavehvash, Zahra
    Fotowat-Ahmady, Ali
    IEEE SENSORS JOURNAL, 2024, 24 (17) : 27578 - 27586
  • [38] Poisson-noise weighted filter for time-of-flight positron emission tomography
    Gengsheng L. Zeng
    Li Lv
    Qiu Huang
    Visual Computing for Industry, Biomedicine, and Art, 3
  • [39] Poisson-noise weighted filter for time-of-flight positron emission tomography
    Zeng, Gengsheng L.
    Lv, Li
    Huang, Qiu
    VISUAL COMPUTING FOR INDUSTRY BIOMEDICINE AND ART, 2020, 3 (01)
  • [40] Image Signal-to-Noise Ratio in Optical Coherence Tomography is Dependent Upon Axial Resolution
    Harper, Danielle J.
    Vakoc, Benjamin J.
    OPTICAL COHERENCE IMAGING TECHNIQUES AND IMAGING IN SCATTERING MEDIA IV, 2021, 11924