EFFECTS OF QUANTIZATION OF TIME-OF-FLIGHT (TOF) MEASUREMENTS ON IMAGE SIGNAL-TO-NOISE RATIO IN TOF EMISSION TOMOGRAPHY

被引:2
|
作者
POLITTE, DG
HOLMES, TJ
SNYDER, DL
机构
关键词
D O I
10.1109/TNS.1983.4332364
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
引用
收藏
页码:720 / 722
页数:3
相关论文
共 50 条
  • [1] Evaluation of Image Signal-to-Noise Ratio in Time-of-flight PET
    Clementel, Enrico
    Vandenberghe, Stefaan
    Karp, Joel S.
    Surti, Suleman
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3917 - 3921
  • [2] Signal to noise ratio in simulations of time-of-flight positron emission tomography
    Harrison, RL
    Alessio, AM
    Kinahan, PE
    Lewellen, TK
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 4080 - 4083
  • [3] Comparison of Image Signal-to-noise Ratio and Noise Equivalent Counts in Time-of-flight PET
    Clementel, Enrico
    Vandenberghe, Stefaan
    Karp, Joel S.
    Surti, Suleman
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3622 - 3625
  • [4] Effect of randoms on signal-to-noise ratio in TOF PET
    Conti, Maurizio
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (03) : 1188 - 1193
  • [5] Signal-to-Noise Gain at Variable Randoms Ratio in TOF PET
    Mettivier, Giovanni
    Tabacchini, Valerio
    Conti, Maurizio
    Russo, Paolo
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (05) : 1948 - 1957
  • [6] Stopping power measurements with the Time-of-Flight (ToF) technique
    Fontana, Cristiano L.
    Chen, Chien-Hung
    Crespillo, Miguel L.
    Graham, Joseph T.
    Xue, Haizhou
    Zhang, Yanwen
    Weber, William J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2016, 366 : 104 - 116
  • [7] Accelerated time-of-flight (TOF) PET image reconstruction using TOF bin subsetization
    Mehranian, Abolfazl
    Zaidi, Habib
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [8] Improvement in Signal-to-Noise Ratio at Variable Random Fraction in TOF PET
    Tabacchini, V.
    Mettivier, G.
    Conti, M.
    Russo, P.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2761 - 2764
  • [9] The effects of object size, attenuation, scatter, and random coincidences on signal to noise ratio in simulations of time-of-flight positron emission tomography
    Harrison, Robert L.
    Gillispie, Steven B.
    Alessio, Adam M.
    Kinahan, Paul E.
    Lewellen, Thomas K.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1900 - 1904
  • [10] Deep learning–based time-of-flight (ToF) image enhancement of non-ToF PET scans
    Abolfazl Mehranian
    Scott D. Wollenweber
    Matthew D. Walker
    Kevin M. Bradley
    Patrick A. Fielding
    Martin Huellner
    Fotis Kotasidis
    Kuan-Hao Su
    Robert Johnsen
    Floris P. Jansen
    Daniel R. McGowan
    European Journal of Nuclear Medicine and Molecular Imaging, 2022, 49 : 3740 - 3749