EFFECT OF POTENTIAL INTERFERENCE FACTORS ON PERFORMANCE OF ENZYME-IMMUNOASSAY AND LATEX AGGLUTINATION ASSAY FOR CRYPTOCOCCAL ANTIGEN

被引:22
|
作者
ENGLER, HD
SHEA, YR
机构
关键词
D O I
10.1128/JCM.32.9.2307-2308.1994
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
The PREMIER Cryptococcal Antigen Enzyme Immunoassay (Meridian Diagnostics) did not give discrepant results with rheumatoid factor, syneresis fluid, or serum macroglobulins from systemic lupus erythematosis patients. The Cryptococcal Antigen Latex Agglutination System (Meridian Diagnostics) did cross-react with syneresis fluid but not with the other serum factors tested.
引用
收藏
页码:2307 / 2308
页数:2
相关论文
共 50 条
  • [31] COMPARISON OF LATEX AGGLUTINATION, INDIRECT IMMUNOFLUORESCENT ANTIBODY, AND ENZYME-IMMUNOASSAY METHODS FOR SERODIAGNOSIS OF ROCKY-MOUNTAIN-SPOTTED-FEVER IN DOGS
    GREENE, CE
    MARKS, MA
    LAPPIN, MR
    BREITSCHWERDT, EB
    WOLSKI, NA
    BURGDORFER, W
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 1993, 54 (01) : 20 - 28
  • [32] HUMAN ANTIMURINE ANTIBODY INTERFERENCE IN MEASUREMENT OF CARCINOEMBRYONIC ANTIGEN ASSESSED WITH A DOUBLE-ANTIBODY ENZYME-IMMUNOASSAY
    PRICE, T
    BEATTY, BG
    BEATTY, JD
    MCNALLY, AJ
    CLINICAL CHEMISTRY, 1991, 37 (01) : 51 - 57
  • [33] IMPROVED REACTION BUFFERS FOR SOLID-PHASE ENZYME-IMMUNOASSAY WITHOUT INTERFERENCE BY SERUM FACTORS
    KATO, K
    UMEDA, Y
    SUZUKI, F
    KOSAKA, A
    CLINICA CHIMICA ACTA, 1980, 102 (2-3) : 261 - 265
  • [34] AN INTERFERON ASSAY BASED ON YIELD REDUCTION OF VESICULAR STOMATITIS-VIRUS ANTIGEN MEASURED BY ENZYME-IMMUNOASSAY
    SALONEN, R
    SALMI, A
    JOURNAL OF VIROLOGICAL METHODS, 1982, 5 (3-4) : 143 - 149
  • [35] Comparison of a commercial reversed passive latex agglutination assay to an enzyme immunoassay for the detection of shiga toxin-producing Escherichia coli
    Carroll, KC
    Adamson, K
    Korgenski, K
    Croft, A
    Hankemeier, R
    Daly, J
    Park, CH
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2003, 22 (11) : 689 - 692
  • [36] Comparison of a Commercial Reversed Passive Latex Agglutination Assay to an Enzyme Immunoassay for the Detection of Shiga Toxin-Producing Escherichia coli
    K. C. Carroll
    K. Adamson
    K. Korgenski
    A. Croft
    R. Hankemeier
    J. Daly
    C. H. Park
    European Journal of Clinical Microbiology and Infectious Diseases , 2003, 22 : 689 - 692
  • [37] COMPARISON OF CULTURE FOR GROUP-B STREPTOCOCCUS VERSUS ENZYME-IMMUNOASSAY AND LATEX AGGLUTINATION RAPID TESTS - RESULTS IN 250 PATIENTS DURING LABOR
    GREENSPOON, JS
    FISHMAN, A
    WILCOX, JG
    GREENSPOON, RL
    LEWIS, W
    OBSTETRICS AND GYNECOLOGY, 1991, 77 (01): : 97 - 100
  • [38] LOW-YIELD OF SCREENING FOR CRYPTOCOCCAL ANTIGEN BY LATEX AGGLUTINATION ASSAY ON SERUM AND CEREBROSPINAL-FLUID FROM DANISH PATIENTS WITH AIDS OR ARC
    HOFFMANN, S
    STENDERUP, J
    MATHIESEN, LR
    SCANDINAVIAN JOURNAL OF INFECTIOUS DISEASES, 1991, 23 (06) : 697 - 702
  • [39] PERFORMANCE EVALUATION OF A PARTICLE AGGLUTINATION-TEST FOR ANTIBODY TO HUMAN-IMMUNODEFICIENCY-VIRUS-1 - COMPARISON WITH ENZYME-IMMUNOASSAY
    ELAVIA, AJ
    THOMAS, A
    NANDI, J
    COYAJI, GD
    BHAVALKARPOTDAR, V
    VOX SANGUINIS, 1995, 69 (01) : 23 - 26
  • [40] EFFECT OF ULTRASONIC IRRADIATION ON THE DISSOCIATION OF ANTIGEN-ANTIBODY COMPLEXES - APPLICATION TO HOMOGENEOUS ENZYME-IMMUNOASSAY
    HAGA, M
    SHIMURA, T
    NAKAMURA, T
    KATO, Y
    SUZUKI, Y
    CHEMICAL & PHARMACEUTICAL BULLETIN, 1987, 35 (09) : 3822 - 3830